Literature DB >> 22967096

Detection of total and A1c-glycosylated hemoglobin in human whole blood using sandwich immunoassays on polydimethylsiloxane-based antibody microarrays.

Huang-Han Chen1, Chih-Hsing Wu, Mei-Ling Tsai, Yi-Jing Huang, Shu-Hui Chen.   

Abstract

The percentage of glycosylated hemoglobin A1c (%GHbA1c) in human whole blood indicates the average plasma glucose concentration over a prolonged period of time and is used to diagnose diabetes. However, detecting GHbA1c in the whole blood using immunoassays has limited detection sensitivity due to its low percentage in total hemoglobin (tHb) and interference from various glycan moieties in the sample. We have developed a sandwich immunoassay using an antibody microarray on a polydimethylsiloxane (PDMS) substrate modified with fluorinated compounds to detect tHb and glycosylated hemoglobin A1c (GHbA1c) in human whole blood without sample pretreatment. A polyclonal antibody against hemoglobin (Hb) immobilized on PDMS is used as a common capture probe to enrich all forms of Hb followed by detection via monoclonal anti-Hb and specific monoclonal anti-GHbA1c antibodies for tHb and GHbA1c detection, respectively. This method prevents the use of glycan binding molecules and dramatically reduces the background interference, yielding a detection limit of 3.58 ng/mL for tHb and 0.20 ng/mL for GHbA1c. The fluorinated modification on PDMS is superior to the glass substrate and eliminates the need for the blocking step which is required in commercial enzyme linked immunosorbent assay (ELISA) kits. Moreover, the detection sensitivity for GHbA1c is 4-5 orders of magnitude higher, but the required sample amount is 25 times less than the commercial method. On the basis of patient sample data, a good linear correlation between %GHbA1c values determined by our method and the certified high performance liquid chromatography (HPLC) standard method is shown with R(2) > 0.98, indicating the great promise of the developed method for clinical applications.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22967096     DOI: 10.1021/ac301756d

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

Review 1.  Proteins and Proteoforms: New Separation Challenges.

Authors:  Fred E Regnier; JinHee Kim
Journal:  Anal Chem       Date:  2017-12-18       Impact factor: 6.986

2.  Truncated aptamers for total and glycated hemoglobin, and their integration into a graphene oxide-based fluorometric method for high-throughput screening for diabetes.

Authors:  Abrar Yousef Almusharraf; Shimaa Eissa; Mohammed Zourob
Journal:  Mikrochim Acta       Date:  2018-04-19       Impact factor: 5.833

3.  Label-free spectrochemical probe for determination of hemoglobin glycation in clinical blood samples.

Authors:  Rishikesh Pandey; Surya P Singh; Chi Zhang; Gary L Horowitz; Niyom Lue; Luis Galindo; Ramachandra R Dasari; Ishan Barman
Journal:  J Biophotonics       Date:  2018-06-19       Impact factor: 3.207

4.  Magnetized carbon nanotubes for visual detection of proteins directly in whole blood.

Authors:  Yan Huang; Yongqiang Wen; Kwaku Baryeh; Sunitha Takalkar; Michelle Lund; Xueji Zhang; Guodong Liu
Journal:  Anal Chim Acta       Date:  2017-09-27       Impact factor: 6.558

5.  A compact immunoassay platform based on a multicapillary glass plate.

Authors:  Shuhua Xue; Hulie Zeng; Jianmin Yang; Hizuru Nakajima; Katsumi Uchiyama
Journal:  Sensors (Basel)       Date:  2014-05-23       Impact factor: 3.576

6.  Ferrocene-Labelled Electroactive Aptamer-Based Sensors (Aptasensors) for Glycated Haemoglobin.

Authors:  Xue-Qing Feng; Yi Ju; Wei-Tao Dou; Qing Li; Zhong-Gan Jin; Xiao-Peng He; Tony D James; Bang-Ce Ye
Journal:  Molecules       Date:  2021-11-23       Impact factor: 4.411

7.  A novel biosensor based on Blu-ray disc coating film for determination of total amino acid content in tea leaves.

Authors:  Lanling Chu; Yunzheng Wang; Yu Zhou; Xuejun Kang
Journal:  RSC Adv       Date:  2021-12-13       Impact factor: 4.036

8.  Aptamer- Based Label-Free Electrochemical Biosensor Array for the Detection of Total and Glycated Hemoglobin in Human Whole Blood.

Authors:  Shimaa Eissa; Mohammed Zourob
Journal:  Sci Rep       Date:  2017-04-21       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.