Literature DB >> 22964863

Automated tumour boundary delineation on (18)F-FDG PET images using active contour coupled with shifted-optimal thresholding method.

Kitiwat Khamwan1, Anchali Krisanachinda, Charnchai Pluempitiwiriyawej.   

Abstract

This study presents an automatic method to trace the boundary of the tumour in positron emission tomography (PET) images. It has been discovered that Otsu's threshold value is biased when the within-class variances between the object and the background are significantly different. To solve the problem, a double-stage threshold search that minimizes the energy between the first Otsu's threshold and the maximum intensity value is introduced. Such shifted-optimal thresholding is embedded into a region-based active contour so that both algorithms are performed consecutively. The efficiency of the method is validated using six sphere inserts (0.52-26.53 cc volume) of the IEC/2001 torso phantom. Both spheres and phantom were filled with (18)F solution with four source-to-background ratio (SBR) measurements of PET images. The results illustrate that the tumour volumes segmented by combined algorithm are of higher accuracy than the traditional active contour. The method had been clinically implemented in ten oesophageal cancer patients. The results are evaluated and compared with the manual tracing by an experienced radiation oncologist. The advantage of the algorithm is the reduced erroneous delineation that improves the precision and accuracy of PET tumour contouring. Moreover, the combined method is robust, independent of the SBR threshold-volume curves, and it does not require prior lesion size measurement.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22964863     DOI: 10.1088/0031-9155/57/19/5995

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Optimising delineation accuracy of tumours in PET for radiotherapy planning using blind deconvolution.

Authors:  A Guvenis; A Koc
Journal:  Radiat Prot Dosimetry       Date:  2015-04-01       Impact factor: 0.972

2.  Design and evaluation of an accurate CNR-guided small region iterative restoration-based tumor segmentation scheme for PET using both simulated and real heterogeneous tumors.

Authors:  Alpaslan Koç; Albert Güveniş
Journal:  Med Biol Eng Comput       Date:  2019-12-17       Impact factor: 2.602

3.  Comparison of novel multi-level Otsu (MO-PET) and conventional PET segmentation methods for measuring FDG metabolic tumor volume in patients with soft tissue sarcoma.

Authors:  Inki Lee; Hyung-Jun Im; Meiyappan Solaiyappan; Steve Y Cho
Journal:  EJNMMI Phys       Date:  2017-09-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.