Literature DB >> 22962289

Reliability of tunnel measurements and the quadrant method using fluoroscopic radiographs after anterior cruciate ligament reconstruction.

Jaron P Sullivan1, Matthew J Matava, David C Flanigan, Yubo Gao, Carla L Britton, Annunziato Amendola, Brian R Wolf.   

Abstract

BACKGROUND: Anterior cruciate ligament (ACL) reconstruction tunnel placement is often evaluated by radiographs. This study examines the interobserver reliability of various radiographic measurements of ACL tunnels. HYPOTHESIS: When ideal radiographic views are obtained, the interobserver reliability of the measurements among experienced surgeons would be good to excellent. STUDY
DESIGN: Descriptive laboratory study.
METHODS: Tunnels for single-bundle ACL reconstruction were drilled and filled with metal interference screws or a tibial reamer on 73 cadaveric knees. Ideal fluoroscopic radiographs were obtained. Three independent reviewers performed 18 measurements including a modification of the grid method. For the grid method analysis, reviewers fit a 16 × 12 grid to the lateral knee radiograph, and the center of the femoral tunnel was marked. Interobserver reliability of the measurements was performed using intraclass correlation coefficients (ICCs). A precision grouping analysis was performed for the grid measurements to calculate the mean radius and standard deviation grouping distances.
RESULTS: The ICCs were excellent (>.75) for the tibial tunnel angles and tunnel measurements, the clock face measurement, and the Aglietti et al and Jonsson et al measurements. The ICCs were good (.4-.75) for an estimation of graft impingement, Harner et al measurements, and notch height. The mean radius for grid measurements was 0.6 ± 0.4 units (range, 0-2.36 units), with each unit being 1 box in the 16 × 12 grid. When a circle was constructed with a 1.3-unit radius, 95% of the 3 surgeons' measurements would be included in the area of that circle.
CONCLUSION: Reliability of ACL tunnel measurements was good to excellent under ideal circumstances for the majority of measurements. The modified grid method demonstrated very acceptable reliability. CLINICAL RELEVANCE: Measurements with good to excellent reliability can be used to evaluate ACL tunnel placement when ideal radiographic views are obtained.

Mesh:

Year:  2012        PMID: 22962289     DOI: 10.1177/0363546512458086

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  7 in total

1.  The effect of intraoperative fluoroscopy on the accuracy of femoral tunnel placement in single-bundle anatomic ACL reconstruction.

Authors:  Eivind Inderhaug; Allan Larsen; Per Arne Waaler; Torbjørn Strand; Thomas Harlem; Eirik Solheim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-18       Impact factor: 4.342

Review 2.  The Impact of the Multicenter Orthopaedic Outcomes Network (MOON) Research on Anterior Cruciate Ligament Reconstruction and Orthopaedic Practice.

Authors:  T Sean Lynch; Richard D Parker; Ronak M Patel; Jack T Andrish; Kurt P Spindler; Annunziata Amendola; Robert H Brophy; Warren R Dunn; David C Flanigan; Laura J Huston; Morgan H Jones; Christopher C Kaeding; Robert G Marx; Matthew J Matava; Eric C McCarty; Angela D Pedroza; Emily K Reinke; Brian R Wolf; Rick W Wright
Journal:  J Am Acad Orthop Surg       Date:  2015-02-09       Impact factor: 3.020

Review 3.  Plain radiographs can be used for routine assessment of ACL reconstruction tunnel position with three-dimensional imaging reserved for research and revision surgery.

Authors:  Jonathan David Kosy; Vipul I Mandalia
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-02-21       Impact factor: 4.342

4.  Variability of tunnel positioning in fluoroscopic-assisted ACL reconstruction.

Authors:  Shafizadeh Sven; Balke Maurice; Juergen Hoeher; Banerjee Marc
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-11       Impact factor: 4.342

5.  The posterior horn of the lateral meniscus is a reliable novel landmark for femoral tunnel placement in ACL reconstruction.

Authors:  Andreas Weiler; Michael Wagner; Christoph Kittl
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-10-23       Impact factor: 4.342

6.  The morphometry of soft tissue insertions on the tibial plateau: data acquisition and statistical shape analysis.

Authors:  Liying Zheng; Christopher D Harner; Xudong Zhang
Journal:  PLoS One       Date:  2014-05-02       Impact factor: 3.240

7.  Radiologic assessment of femoral and tibial tunnel placement based on anatomic landmarks in arthroscopic single bundle anterior cruciate ligament reconstruction.

Authors:  Sandeep Kumar Nema; Gopisankar Balaji; Sujiv Akkilagunta; Jagdish Menon; Murali Poduval; Dilip Patro
Journal:  Indian J Orthop       Date:  2017 May-Jun       Impact factor: 1.251

  7 in total