Literature DB >> 22959323

Effect of the prosthesis-patient mismatch on long-term clinical outcomes after isolated aortic valve replacement for aortic stenosis: a prospective observational study.

Soonchang Hong1, Gijong Yi, Young-Nam Youn, Sak Lee, Kyung-Jong Yoo, Byung-Chul Chang.   

Abstract

BACKGROUND: The effect of prosthesis-patient mismatch (PPM) on clinical outcomes after aortic valve replacement remains controversial. We evaluated effect of PPM on long-term clinical outcomes after isolated aortic valve replacement in patients with predominant aortic stenosis.
METHODS: We analyzed data from patients with predominant aortic stenosis who underwent isolated aortic valve replacement between January 1995 and July 2010. The indexed effective orifice area, obtained by dividing the in vivo effective orifice area by the patient's body surface area, was used to define PPM as clinically nonsignificant (group I, 224 patients), mild (group II, 52 patients), moderate (group III, 39 patients), and severe (group IV, 36 patients).
RESULTS: Early survival was not significantly different among the groups, but overall survival was decreased gradually in group IV. Overall survival at 12 years was lower in group IV than in group I (92.8% ± 2.7% vs 67.0 ± 10.1, respectively; P = .001). Cardiac-related-death-free survival at 12 years was lower in patients with severe PPM. Left ventricular mass index decreased during the follow-up period in all groups. But left ventricular mass index was less decreased in group IV compared with groups I, II, and III. Age, severe PPM, and ejection fraction <40%, and New York Heart Association Functional Class IV were independent risk factors of overall survival on multivariate analysis. Severe PPM was an independent risk factor for cardiac-related death.
CONCLUSIONS: Severe PPM showed an adverse effect on long-term survival, and was an independent risk factor for cardiac-related death. In addition, patients with severe PPM showed less decreasing left ventricular mass index during follow-up.
Copyright © 2013 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Keywords:  17; 35.2; 35.3; 36.2; AS; AVR; EOA; LVMI; LVOT; PPM; aortic stenosis; aortic valve replacement; effective orifice area; left ventricular mass index; left ventricular outflow tract; prosthesis–patient mismatch

Mesh:

Year:  2012        PMID: 22959323     DOI: 10.1016/j.jtcvs.2012.07.101

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  13 in total

1.  Patient prosthesis mismatch and its impact on left ventricular regression following aortic valve replacement in aortic stenosis patients.

Authors:  Abid Iqbal; Varghese Thomas Panicker; Jayakumar Karunakaran
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2018-08-28

2.  Sutureless valve and rapid deployment valves: a systematic review and meta-analysis of comparative studies.

Authors:  Campbell D Flynn; Michael L Williams; Adam Chakos; Lucy Hirst; Benjamin Muston; David H Tian
Journal:  Ann Cardiothorac Surg       Date:  2020-09

Review 3.  Prosthesis-patient mismatch in aortic stenosis.

Authors:  Kentaro Honda; Yoshitaka Okamura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-10-17

Review 4.  Transcatheter Aortic Valve-in-Valve Procedure in Patients with Bioprosthetic Structural Valve Deterioration.

Authors:  Ross M Reul; Mahesh K Ramchandani; Michael J Reardon
Journal:  Methodist Debakey Cardiovasc J       Date:  2017 Jul-Sep

5.  Impact of prosthesis-patient mismatch on short-term outcomes after aortic valve replacement: a retrospective analysis in East China.

Authors:  Lei Guo; Junnan Zheng; Liangwei Chen; Renyuan Li; Liang Ma; Yiming Ni; Haige Zhao
Journal:  J Cardiothorac Surg       Date:  2017-05-25       Impact factor: 1.637

6.  Konno-Rastan Combined with Manougiaun Root Enlargement for Small Aortic Root with Coronary Anomaly in a Young Woman.

Authors:  Fazal Wahab Khan; Sameh M Said
Journal:  Heart Views       Date:  2019-11-14

7.  Impact of prosthesis-patient mismatch on early and late mortality after aortic valve replacement.

Authors:  Bart M Koene; Mohamed A Soliman Hamad; Wobbe Bouma; Massimo A Mariani; Kathinka C Peels; Jan-Melle van Dantzig; Albert H van Straten
Journal:  J Cardiothorac Surg       Date:  2013-04-17       Impact factor: 1.637

8.  Seventeen-millimeter St. Jude Medical Regent valve in patients with small aortic annulus: dose moderate prosthesis-patient mismatch matter?

Authors:  Jia Hu; Hong Qian; Ya-jiao Li; Jun Gu; Jing Janice Zhao; Er-yong Zhang
Journal:  J Cardiothorac Surg       Date:  2014-01-17       Impact factor: 1.637

9.  Prognosis after surgical replacement with a bioprosthetic aortic valve in patients with severe symptomatic aortic stenosis: systematic review of observational studies.

Authors:  Farid Foroutan; Gordon H Guyatt; Kathleen O'Brien; Eva Bain; Madeleine Stein; Sai Bhagra; Daegan Sit; Rakhshan Kamran; Yaping Chang; Tahira Devji; Hassan Mir; Veena Manja; Toni Schofield; Reed A Siemieniuk; Thomas Agoritsas; Rodrigo Bagur; Catherine M Otto; Per O Vandvik
Journal:  BMJ       Date:  2016-09-28

10.  Prosthesis-patient mismatch after mitral valve replacement: a single-centered retrospective analysis in East China.

Authors:  Armah M Akuffu; Haige Zhao; Junnan Zheng; Yiming Ni
Journal:  J Cardiothorac Surg       Date:  2018-10-03       Impact factor: 1.637

View more