Literature DB >> 2295896

Does measurement of systolic blood pressure with a pulse oximeter correlate with conventional methods?

P Talke1, R J Nichols, D L Traber.   

Abstract

The pulse oximeter is commonly used in the operating room. We evaluated the use of a pulse oximeter to monitor systolic blood pressure in 20 healthy volunteers and 42 anesthetized patients. We compared the pulse oximeter method of measuring systolic blood pressure with the cuff methods using Korotkoff sounds and Doppler ultrasound as well as with direct pressure measurement through an intraarterial cannula. Systolic blood pressure values obtained by pulse oximeter correlated well with values obtained by other conventional methods. The best correlation was found with Doppler ultrasound (r = 0.996) and the worst with arterial cannulation (r = 0.880). We conclude that this method can be used intraoperatively to measure systolic blood pressure.

Entities:  

Mesh:

Year:  1990        PMID: 2295896     DOI: 10.1007/bf02832176

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  8 in total

1.  Comparison of indirect and direct methods of measuring arterial blood pressure.

Authors:  F H VAN BERGEN; D S WEATHERHEAD; A E TRELOAR; A B DOBKIN; J J BUCKLEY
Journal:  Circulation       Date:  1954-10       Impact factor: 29.690

2.  Comparison of blood pressure measurement by Doppler and by pulse oximetry techniques.

Authors:  C T Wallace; J D Baker; C C Alpert; S J Tankersley; J M Conroy; R E Kerns
Journal:  Anesth Analg       Date:  1987-10       Impact factor: 5.108

3.  Blood flow limits and pulse oximeter signal detection.

Authors:  D Lawson; I Norley; G Korbon; R Loeb; J Ellis
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

4.  Direct blood pressure measurement--dynamic response requirements.

Authors:  R M Gardner
Journal:  Anesthesiology       Date:  1981-03       Impact factor: 7.892

5.  Evaluation of pulse oximetry.

Authors:  M Yelderman; W New
Journal:  Anesthesiology       Date:  1983-10       Impact factor: 7.892

6.  Comparison of direct and indirect methods of measuring arterial blood pressure, part III.

Authors:  J M Bruner; L J Krenis; J M Kunsman; A P Sherman
Journal:  Med Instrum       Date:  1981 May-Jun

7.  Recommendations for human blood pressure determination by sphygmomanometers. Subcommittee of the AHA Postgraduate Education Committee.

Authors:  W M Kirkendall; M Feinleib; E D Freis; A L Mark
Journal:  Circulation       Date:  1980-11       Impact factor: 29.690

8.  Spectrophotometric monitoring of arterial oxygen saturation in the fingertip.

Authors:  I Yoshiya; Y Shimada; K Tanaka
Journal:  Med Biol Eng Comput       Date:  1980-01       Impact factor: 2.602

  8 in total
  9 in total

1.  Measurement of systolic blood pressure with a pulse oximeter.

Authors:  R Chawla; A Indrayan; A Bhattacharya
Journal:  J Clin Monit       Date:  1992-04

2.  Monitoring patients during helicopter flight.

Authors:  P Talke; R J Nichols; D L Traber
Journal:  J Clin Monit       Date:  1990-04

3.  Anesthesia and Takayasu's arteritis.

Authors:  Natan Weksler
Journal:  J Anesth       Date:  1995-09       Impact factor: 2.078

4.  Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study.

Authors:  Gerardo Tusman; Cecilia M Acosta; Sven Pulletz; Stephan H Böhm; Adriana Scandurra; Jorge Martinez Arca; Matías Madorno; Fernando Suarez Sipmann
Journal:  J Clin Monit Comput       Date:  2018-12-15       Impact factor: 2.502

5.  A proposal for scientific validation of instruments for indirect blood pressure measurement at rest, during exercise, and in critical care.

Authors:  Y Iyriboz; C M Hearon
Journal:  J Clin Monit       Date:  1994-05

6.  Pulse oximetry plethysmography: A new approach for physiology-directed CPR?

Authors:  Lindsay N Shepard; Robert A Berg; Ryan W Morgan
Journal:  Resuscitation       Date:  2021-10-29       Impact factor: 5.262

7.  Use of pulse oximetry for blood pressure measurement after cardiac surgery.

Authors:  A J Movius; S L Bratton; G K Sorensen
Journal:  Arch Dis Child       Date:  1998-05       Impact factor: 3.791

8.  Distribution of cardiovascular related cells within the human thalamus.

Authors:  S M Oppenheimer; N Kulshreshtha; F A Lenz; Z Zhang; L H Rowland; P M Dougherty
Journal:  Clin Auton Res       Date:  1998-06       Impact factor: 4.435

9.  Pulse oximetry vs non-invasive blood pressure/oscillometry to record blood pressure in neonates: A prospective observational study.

Authors:  Reenu Raju; Mathai Isac
Journal:  J Family Med Prim Care       Date:  2022-06-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.