Literature DB >> 22956643

i-gel™ supraglottic airway in clinical practice: a prospective observational multicentre study.

L Theiler1, M Gutzmann, M Kleine-Brueggeney, N Urwyler, B Kaempfen, R Greif.   

Abstract

BACKGROUND: The i-gel™ supraglottic airway device has been studied in randomized controlled studies, but it has not been evaluated in a large prospective patient cohort. Therefore, we performed this prospective multicentre observational study to evaluate success rates, airway leak pressure, risk factors for i-gel failure, and adverse events.
METHODS: With Ethics Committee approval and waiver of patients' consent, data about anaesthesia providers, patient characteristics, and the performance of the i-gel were recorded in five independent hospitals in Switzerland over a period of 24 months. We analysed success rates, leak pressures, adverse events, and risk factors for failure.
RESULTS: Data from 2049 i-gel uses were analysed. Patients' mean age was 47 (range 6-91) yr. The primary i-gel success rate without changing size was 93%; the overall success rate was 96%. Insertion was deemed very easy or easy in 92%. The mean airway leak pressure was 26 (8) cm H(2)O. The mean anaesthesia time was 67 (42) min. Risk factors associated with i-gel failure were males (P<0.001), impaired mandibular subluxation (P=0.01), poor dentition (P=0.02), and older age (P<0.01). Adverse events recorded were laryngeal spasms (n=25, 1.2%), blood stained airway devices (n=79, 3.9%), transient nerve damage (n=2, 0.1%), one case of transient vasovagal asystole, and one glottic haematoma.
CONCLUSIONS: The i-gel is a reliable supraglottic airway device failing in <5% and providing high airway leak pressures. Males, impaired mandibular subluxation, poor dentition, and older age are risk factors associated with primary device failure. Serious adverse events are rare.

Entities:  

Mesh:

Year:  2012        PMID: 22956643     DOI: 10.1093/bja/aes309

Source DB:  PubMed          Journal:  Br J Anaesth        ISSN: 0007-0912            Impact factor:   9.166


  29 in total

1.  A randomized controlled trial of the effect of preoperative dexmedetomidine on the half maximal effective concentration of propofol for successful i-gel insertion without muscle relaxants.

Authors:  Young-Eun Jang; Yong-Chul Kim; Hyun-Kyu Yoon; Young-Tae Jeon; Jung-Won Hwang; Eugene Kim; Hee-Pyoung Park
Journal:  J Anesth       Date:  2014-11-14       Impact factor: 2.078

2.  Laryngoscopy facilitates successful i-gel insertion by novice doctors: a prospective randomized controlled trial.

Authors:  Yu Miyazaki; Nobuyasu Komasawa; Sayuri Matsunami; Yusuke Kusaka; Toshiaki Minami
Journal:  J Anesth       Date:  2015-04-25       Impact factor: 2.078

Review 3.  Anaesthesia management for bronchoscopic and surgical lung volume reduction.

Authors:  Bastian Grande; Torsten Loop
Journal:  J Thorac Dis       Date:  2018-08       Impact factor: 2.895

4.  Continuous infusion chemotherapy, radiotherapy, and FDG-PET are feasible during extracorporeal membrane oxygenation.

Authors:  Seth J Rotz; Francisco A Almeida; Shlomo Koyfman; Sudhir Krishnan; Guramrinder Singh Thind; William Phillips; James Yun; Anthony Zembillas; Mark Zahniser; Alejandro Bribriesco
Journal:  Pediatr Blood Cancer       Date:  2020-07-16       Impact factor: 3.167

5.  Clinical Comparison of I-Gel Supraglottic Airway Device and Cuffed Endotracheal Tube for Pressure-Controlled Ventilation During Routine Surgical Procedures.

Authors:  Ankur Dhanda; Shalendra Singh; Anju R Bhalotra; Siddharth Chavali
Journal:  Turk J Anaesthesiol Reanim       Date:  2017-10-01

6.  Evaluation of airway management associated hands-off time during cardiopulmonary resuscitation: a randomised manikin follow-up study.

Authors:  Christina Gruber; Sabine Nabecker; Philipp Wohlfarth; Anita Ruetzler; Dominik Roth; Oliver Kimberger; Henrik Fischer; Michael Frass; Kurt Ruetzler
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2013-02-25       Impact factor: 2.953

7.  Comparison of the Disposable Streamlined Liner of the Pharynx Airway and the Disposable I-gel in Anaesthetized, Paralyzed Adults: A Randomized Prospective Study.

Authors:  Khaled El-Radaideh; Ala A Alhowary; Diab Bani Hani
Journal:  Anesthesiol Res Pract       Date:  2015-12-01

8.  Utility of the Aintree Intubation Catheter in fiberoptic tracheal intubation through the three types of intubating supraglottic airways: a manikin simulation study.

Authors:  Ryusuke Ueki; Nobuyasu Komasawa; Kenta Nishimoto; Takashi Sugi; Munetaka Hirose; Yoshiroh Kaminoh
Journal:  J Anesth       Date:  2013-10-17       Impact factor: 2.078

9.  Difficult Airway Society 2015 guidelines for management of unanticipated difficult intubation in adults.

Authors:  C Frerk; V S Mitchell; A F McNarry; C Mendonca; R Bhagrath; A Patel; E P O'Sullivan; N M Woodall; I Ahmad
Journal:  Br J Anaesth       Date:  2015-11-10       Impact factor: 9.166

10.  Comparison of three supraglottic airway devices for airway rescue in the prone position: A manikin-based study.

Authors:  Babita Gupta; Surender Gupta; Bijaya Hijam; Pallavi Shende; Vimi Rewari
Journal:  J Emerg Trauma Shock       Date:  2015 Oct-Dec
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.