Literature DB >> 22951476

Study of the stability of EPR signals after irradiation of fingernail samples.

Ricardo A Reyes1, François Trompier, Alexander Romanyukha.   

Abstract

Previous studies have suggested that the electron paramagnetic resonance in fingernails can be used for radiation dosimetry purposes. Use of fingernails as an emergency dosimeter has benefits of easy, noninvasive sampling and fast dose measurements (∼10 min) potentially in field conditions and almost immediately after an exposure event. This study represents the next step in the development of EPR fingernail dosimetry; e.g., evaluation of the stability of the radiation-induced signal (RIS) at different storage and irradiation conditions. RIS fading during storage in both stressed (untreated) and unstressed (soaked in water) samples (n = 20) was studied at two temperature conditions: freezing (temp ≈ -20°C) and room temperature (20-24°C). Fingernail samples with the same clipping size and number and irradiated to 15 and 20 Gy were measured for over 200 d. Those irradiated to 100 and 200 Gy were measured for 114 d. The other group of samples irradiated to 1, 3, 8, and 20 Gy was followed for 25 mo of storage time. This study demonstrated that all samples that were kept at low freezing temperatures showed a stable RIS with no significant fading. All samples that were kept at room temperatures showed an initial fading of the signal with a slow rise of the EPR signal after irradiation with time to a saturation level. Obtained results allow making recommendations on the appropriate storage conditions of fingernails for EPR dosimetry use.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22951476     DOI: 10.1097/HP.0b013e31824ac338

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  8 in total

1.  The effect of sunlight and UV lamps on EPR signal in nails.

Authors:  Agnieszka Marciniak; Bartłomiej Ciesielski; Małgorzata Juniewicz; Anita Prawdzik-Dampc; Mirosław Sawczak
Journal:  Radiat Environ Biophys       Date:  2019-02-10       Impact factor: 1.925

2.  Electron paramagnetic resonance radiation dose assessment in fingernails of the victim exposed to high dose as result of an accident.

Authors:  Alexander Romanyukha; François Trompier; Ricardo A Reyes; Doran M Christensen; Carol J Iddins; Stephen L Sugarman
Journal:  Radiat Environ Biophys       Date:  2014-06-24       Impact factor: 1.925

3.  Comparison of Continuous Wave and Rapid Scan X-band Electron Paramagnetic Resonance of Irradiated Clipped Fingernails.

Authors:  Hanan Elajaili; Joseph McPeak; Alexander Romanyukha; Priyanka Aggarwal; Sandra S Eaton; Gareth R Eaton
Journal:  Radiat Prot Dosimetry       Date:  2016-09-02       Impact factor: 0.972

4.  Emergency EPR dosimetry technique using vacuum-stored dry nails.

Authors:  S Sholom; S W S McKeever
Journal:  Radiat Meas       Date:  2016-02-06       Impact factor: 1.898

5.  Stability of X-band EPR signals from fingernails under vacuum storage.

Authors:  Sergey Sholom; Stephen McKeever
Journal:  Radiat Phys Chem Oxf Engl 1993       Date:  2017-06-12       Impact factor: 2.858

6.  Development and validation of an ex vivo electron paramagnetic resonance fingernail biodosimetric method.

Authors:  Xiaoming He; Steven G Swarts; Eugene Demidenko; Ann B Flood; Oleg Grinberg; Jiang Gui; Michael Mariani; Stephen D Marsh; Andres E Ruuge; Jason W Sidabras; Dmitry Tipikin; Dean E Wilcox; Harold M Swartz
Journal:  Radiat Prot Dosimetry       Date:  2014-05-06       Impact factor: 0.972

7.  State of the art in nail dosimetry: free radicals identification and reaction mechanisms.

Authors:  F Trompier; A Romanyukha; R Reyes; H Vezin; F Queinnec; D Gourier
Journal:  Radiat Environ Biophys       Date:  2014-01-28       Impact factor: 1.925

8.  Behavior of the electron spin resonance signals in X-ray irradiated human fingernails for the establishment of a dose reconstruction procedure.

Authors:  Seiko Hirota; Chryzel Angelica B Gonzales; Hiroshi Yasuda
Journal:  J Radiat Res       Date:  2021-09-13       Impact factor: 2.724

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.