Literature DB >> 22947104

A systematic review of the clinical performance of tooth-retained and implant-retained double crown prostheses with a follow-up of ≥ 3 years.

Rohini Verma1, Tim Joda, Urs Brägger, Julia-Gabriela Wittneben.   

Abstract

PURPOSE: The objective of this review was to systematically screen the literature for data related to the survival and complication rates observed with dental or implant double crown abutments and removable prostheses under functional loading for at least 3 years.
MATERIALS AND METHODS: A systematic review of the dental literature from January 1966 to December 2009 was performed in electronic databases (PubMed and Embase) as well as by an extensive hand search to investigate the clinical outcomes of double crown reconstructions.
RESULTS: From the total of 2412 titles retrieved from the search, 65 were selected for full-text review. Subsequently, 17 papers were included for data extraction. An estimation of the cumulative survival and complication rates was not feasible due to the lack of detailed information. Tooth survival rates for telescopic abutment teeth ranged from 82.5% to 96.5% after an observation period of 3.4 to 6 years, and for tooth-supported double crown retained dentures from 66.7% to 98.6% after an observation period of 6 to 10 years. The survival rates of implants were between 97.9% and 100% and for telescopic-retained removable dental prostheses with two mandibular implants, 100% after 3.0 and 10.4 years. The major biological complications affecting the tooth abutments were gingival inflammation, periodontal disease, and caries. The most frequent technical complications were loss of cementation and loss of facings.
CONCLUSIONS: The main findings of this review are: (I) double crown tooth abutments and dentures demonstrated a wide range of survival rates. (II) Implant-supported mandibular overdentures demonstrated a favorable long-term prognosis. (III) A greater need for prosthetic maintenance is required for both tooth-supported and implant-supported reconstructions. (IV) Future areas of research would involve designing appropriate longitudinal studies for comparisons of survival and complication rates of different reconstruction designs.
© 2012 by the American College of Prosthodontists.

Entities:  

Mesh:

Year:  2012        PMID: 22947104     DOI: 10.1111/j.1532-849X.2012.00905.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  11 in total

1.  Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial.

Authors:  Franz Sebastian Schwindling; Franziska Lehmann; Sophia Terebesi; Nicoleta Corcodel; Andreas Zenthöfer; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2017-02-11       Impact factor: 3.573

2.  Survival rate of removable partial dentures with complete arch reconstruction using double crowns: a retrospective study.

Authors:  Koichi Yoshino; Koji Ito; Masahiko Kuroda; Naoki Sugihara
Journal:  Clin Oral Investig       Date:  2019-07-27       Impact factor: 3.573

3.  Retention force of removable partial dentures with different double crowns.

Authors:  Christin Arnold; Jeremias Hey; Jürgen M Setz; Arne F Boeckler; Ramona Schweyen
Journal:  Clin Oral Investig       Date:  2017-11-03       Impact factor: 3.573

4.  Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses.

Authors:  Silvia Brandt; Jan Brandt; Ali-Reza Ketabi; Hans-Christoph Lauer; Anna Kunzmann
Journal:  Clin Oral Investig       Date:  2018-05-19       Impact factor: 3.573

5.  Electroplated and cast double crown-retained removable dental prostheses: 6-year results from a randomized clinical trial.

Authors:  Thomas Stober; Justo Lorenzo Bermejo; Anne-Christiane Séché; Franziska Lehmann; Peter Rammelsberg; Wolfgang Bömicke
Journal:  Clin Oral Investig       Date:  2014-10-11       Impact factor: 3.573

6.  Clinical outcomes of rigid and non-rigid telescopic double-crown-retained removable dental prostheses: An analytical review.

Authors:  Jeong-Gyo Seo; Jin-Hyun Cho
Journal:  J Adv Prosthodont       Date:  2020-02-20       Impact factor: 1.904

7.  Comparison of tensile bond strength of ball attachments made of different materials to root canal dentin after chewing simulation.

Authors:  Ahmed Mostafa Abdelfattah Mohamed; Mahmoud El-Moutassem Bellah El Homossany; Sarah Mohamed Abdelmoniem; Tariq Yehia Abdelrahman
Journal:  BMC Oral Health       Date:  2022-06-24       Impact factor: 3.747

8.  Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns.

Authors:  Sven Rinke; Ralf Buergers; Dirk Ziebolz; Matthias Roediger
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

Review 9.  Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws.

Authors:  Gunnar E Carlsson
Journal:  J Adv Prosthodont       Date:  2014-08-14       Impact factor: 1.904

10.  Digitally Fabricated Dentures for Full Mouth Rehabilitation with Zirconia, Polyetheretherketone and Selective Laser Melted Ti-6Al-4V Material.

Authors:  Wei-Ting Lee; Yung-Chung Chen
Journal:  Int J Environ Res Public Health       Date:  2022-03-04       Impact factor: 3.390

View more