Literature DB >> 22944313

Microleakage of different sealing materials in access holes of internal connection implant systems.

Sung-Do Park1, Yoon Lee, Yu-Lee Kim, Sang-Hui Yu, Ji-Myung Bae, Hye-Won Cho.   

Abstract

STATEMENT OF PROBLEM: Current implant systems cannot completely prevent microleakage from the access holes of screw-retained implant prostheses, which may constitute risks to the clinical success of the implants.
PURPOSE: The purpose of this study was to evaluate the levels of microleakage through the access holes of screw-retained implant prostheses sealed with different materials.
MATERIAL AND METHODS: An implant with an internal hexagonal configuration was connected to a temporary abutment with an acrylic resin crown. The apical 6.5 mm of the access hole was filled with 1 of the following materials: cotton pellet, silicone sealing material, vinyl polysiloxane, or gutta-percha. The remaining coronal 3 mm was sealed with composite resin. Cyclic loading with 21 N at 1 Hz was applied 16,000 times to the specimens in 0.5% basic fuchsin solution according to the long axis of the tooth. Basic fuchsin dye which penetrated into the internal wall of the abutment through the access hole was dissolved with methyl alcohol. Then the absorbance was measured by a spectrophotometer at 540 nm to evaluate the degree of microleakage. The results were statistically analyzed with 1-way ANOVA and the Tukey HSD test.
RESULTS: From greatest to least, the levels of microleakage were in the following order: cotton pellet, silicone sealing material, vinyl polysiloxane, and gutta-percha. The microleakage associated with gutta-percha was not significantly different from that of vinyl polysiloxane.
CONCLUSIONS: When sealing the access holes of screw-retained implant prostheses, gutta-percha or vinyl polysiloxane would help reduce microleakage.
Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22944313     DOI: 10.1016/S0022-3913(12)60143-7

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  10 in total

Review 1.  Clinical applications of polytetrafluoroethylene (PTFE) tape in restorative dentistry.

Authors:  M M Sattar; M Patel; A Alani
Journal:  Br Dent J       Date:  2017-02-10       Impact factor: 1.626

2.  Peri-implantitis. Part 2: Prevention and maintenance of peri-implant health.

Authors:  A Alani; K Bishop
Journal:  Br Dent J       Date:  2014-09       Impact factor: 1.626

Review 3.  Microleakage at the Different Implant Abutment Interface: A Systematic Review.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary; Shail Kumari
Journal:  J Clin Diagn Res       Date:  2017-06-01

4.  Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent.

Authors:  Pedro Ferrás Fernandes; Liliana Grenho; Maria Helena Fernandes; João Carlos Sampaio-Fernandes; Pedro Sousa Gomes
Journal:  Odontology       Date:  2021-08-27       Impact factor: 2.634

5.  Leakage evaluation of original and compatible implant-abutment connections: In vitro study using Rhodamine B.

Authors:  Antoine Berberi; George Tehini; Khaldoun Rifai; Farah Bou Nasser Eddine; Bassam Badran; Haidar Akl
Journal:  J Dent Biomech       Date:  2014-08-11

6.  Effect of abutment screw length and cyclic loading on removal torque in external and internal hex implants.

Authors:  Hnd Hadi Mohammed; Jin-Han Lee; Ji-Myung Bae; Hye-Won Cho
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

7.  Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit.

Authors:  Jorge Vélez; Jesús Peláez; Carlos López-Suárez; Rubén Agustín-Panadero; Celia Tobar; María J Suárez
Journal:  J Clin Med       Date:  2020-07-24       Impact factor: 4.241

8.  Microleakage and Bacterial Adhesion with Three Restorative Materials Used to Seal Screw-access Channels of Implant Abutments: An In vitro Study.

Authors:  Firas Khalid AlQarawi; Baneen Mansour AlShammasi; Zainab Ahmed AlBasry; Heba Zaki AlAwami; Doaa Mostafa AlEraky; Reem Yussuf AlJindan; Hamad Saleh Alrumaih; Faris Abdullah Alshahrani
Journal:  Saudi J Med Med Sci       Date:  2021-09-04

9.  Passant Connection Screw of Dental Implants: An In Vitro SEM Preliminary Study.

Authors:  Gabriele Cervino; Antonino Germanà; Luca Fiorillo; Cesare D'Amico; Francesco Abbate; Marco Cicciù
Journal:  Biomed Res Int       Date:  2022-04-21       Impact factor: 3.246

10.  Evaluation of sealing efficacy and removal convenience of sealing materials for implant abutment screw access holes.

Authors:  Huangjun Zhou; Sixian Ye; Xingyu Lyu; Hao Feng; Min Liu; Cai Wen
Journal:  BMC Oral Health       Date:  2022-08-25       Impact factor: 3.747

  10 in total