Abstract

A direct, sensitive, near-real-time, handheld optical immunoassay device was developed to detect Salmonella typhimurium in the naturally occurring liquid from fresh poultry packages (hereafter "chicken matrix"), with just single pipetting of sample (i.e., no filtration, culturing and/or isolation, thus reducing the assay time and the error associated with them). Carboxylated, polystyrene microparticles were covalently conjugated with anti-Salmonella, and the immunoagglutination due to the presence of Salmonella was detected by reading the Mie scatter signals from the microfluidic channels using a handheld device. The presence of chicken matrix did not affect the light scatter signal, since the optical parameters (particle size d, wavelength of incident light λ and scatter angle θ) were optimized to minimize the effect of sample matrix (animal tissues and blood proteins, etc.). The sample was loaded into a microfluidic chip that was split into two channels, one pre-loaded with vacuum-dried, antibody-conjugated particles and the other with vacuum-dried, bovine serum albumin-conjugated particles. This eliminated the need for a separate negative control, effectively minimizing chip-to-chip and sample-to-sample variations. Particles and the sample were diffused in-channel through chemical agitation by Tween 80, also vacuum-dried within the microchannels. Sequential mixing of the sample to the reagents under a strict laminar flow condition synergistically improved the reproducibility and linearity of the assay. In addition, dried particles were shown to successfully detect lower Salmonella concentrations for up to 8 weeks. The handheld device contains simplified circuitry eliminating unnecessary adjustment stages, providing a stable signal, thus maximizing sensitivity. Total assay time was 10 min, and the detection limit 10 CFU mL(-1) was observed in all matrices, demonstrating the suitability of this device for field assays.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22939509     DOI: 10.1016/j.bios.2012.07.076

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  11 in total

Review 1.  Biosensors for whole-cell bacterial detection.

Authors:  Asif Ahmed; Jo V Rushworth; Natalie A Hirst; Paul A Millner
Journal:  Clin Microbiol Rev       Date:  2014-07       Impact factor: 26.132

2.  In situ, dual-mode monitoring of organ-on-a-chip with smartphone-based fluorescence microscope.

Authors:  Soohee Cho; Argel Islas-Robles; Ariana M Nicolini; Terrence J Monks; Jeong-Yeol Yoon
Journal:  Biosens Bioelectron       Date:  2016-07-07       Impact factor: 10.618

3.  Impedimetric detection of bacteria by using a microfluidic chip and silver nanoparticle based signal enhancement.

Authors:  Renjie Wang; Yi Xu; Thomas Sors; Joseph Irudayaraj; Wen Ren; Rong Wang
Journal:  Mikrochim Acta       Date:  2018-02-19       Impact factor: 5.833

4.  A portable, shock-proof, surface-heated droplet PCR system for Escherichia coli detection.

Authors:  Scott V Angus; Soohee Cho; Dustin K Harshman; Jae-Young Song; Jeong-Yeol Yoon
Journal:  Biosens Bioelectron       Date:  2015-06-29       Impact factor: 10.618

5.  Point-of-care SARS-CoV-2 sensing using lens-free imaging and a deep learning-assisted quantitative agglutination assay.

Authors:  Colin J Potter; Yanmei Hu; Zhen Xiong; Jun Wang; Euan McLeod
Journal:  Lab Chip       Date:  2022-09-27       Impact factor: 7.517

6.  High-Speed Lens-Free Holographic Sensing of Protein Molecules Using Quantitative Agglutination Assays.

Authors:  Zhen Xiong; Colin J Potter; Euan McLeod
Journal:  ACS Sens       Date:  2021-02-15       Impact factor: 7.711

7.  A Low-Cost Micro-Volume Nephelometric System for Quantitative Immunoagglutination Assays.

Authors:  Qiqi Sun; Wei Zheng; Chao Lin; Dongxuan Shen
Journal:  Sensors (Basel)       Date:  2019-10-09       Impact factor: 3.576

Review 8.  Lab-on-a-chip pathogen sensors for food safety.

Authors:  Jeong-Yeol Yoon; Bumsang Kim
Journal:  Sensors (Basel)       Date:  2012-08-06       Impact factor: 3.576

9.  Rapid and reagentless detection of microbial contamination within meat utilizing a smartphone-based biosensor.

Authors:  Pei-Shih Liang; Tu San Park; Jeong-Yeol Yoon
Journal:  Sci Rep       Date:  2014-08-05       Impact factor: 4.379

Review 10.  Application of Microfluidic Chip Technology in Food Safety Sensing.

Authors:  Hongwei Gao; Chunlei Yan; Wei Wu; Juan Li
Journal:  Sensors (Basel)       Date:  2020-03-24       Impact factor: 3.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.