Effect of a single-piece and a three-piece acrylic sharp-edged IOL on posterior capsule opacification.

Georgios Mylonas1, Martin Prskavec, Ramin Baradaran-Dilmaghani, Nadja Karnik, Wolf Buehl, Matthias Wirtitsch.   

Abstract

BACKGROUND: To compare the intensity of posterior capsule opacification (PCO) between two intraocular lenses (IOLs) of the same optic material, but with different haptic design (1-piece vs. 3-piece).
METHODS: This prospective intraindividual controlled cohort study comprised eighty eyes of 40 patients with bilateral age-related cataract. Each patient received a Polylens Y10 (Polytech, Germany) 1-piece IOL in 1 eye and a Polylens Y30 (Polytech, Germany) 3-piece IOL in the contralateral eye. The IOL type in the first operated eye was randomly assigned before patient recruitment. Digital slitlamp photographs were taken 1 year postoperatively using a standardized photographic technique for regeneratory PCO. The amount of PCO was assessed subjectively at the slitlamp and objectively using automated image-analysis software.
RESULTS: The Polylens Y10 (1-piece) group showed significantly higher regeneratory and fibrotic PCO scores 1 year after surgery in subjective slitlamp evaluation, however not with objective evaluation using automated image-analysis software. Subjective PCO assessment resulted in a mean PCO score (scale = 0-10) of 1.6 in the Polylens Y10 group and 0.6 in the Polylens Y30 group at 1 year (p < 0.05). The mean automated image-analysis software PCO score was 1.5 in the Polylens Y10 group and 0.9 in the Polylens Y30 group (p = 0.6).
CONCLUSION: Both investigated IOLs showed good clinical performance regarding PCO, BCVA and IOL-centration. The Polylens Y10 IOL showed slightly more regeneratory PCO than the 3-piece acrylic IOL 1 year after surgery.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22938910     DOI: 10.3109/02713683.2012.717242

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  5 in total

1.  Effect of four different intraocular lenses on posterior capsule opacification.

Authors:  Rahmi Duman; Fatih Karel; Pelin Özyol; Can Ateş
Journal:  Int J Ophthalmol       Date:  2015-02-18       Impact factor: 1.779

2.  Influence of super-hydrophobic silicone rubber substrate on the growth and differentiation of human lens epithelial cells.

Authors:  Liuxueying Zhong; Jiayi Jin; Danying Zheng; Weisheng Guan; Yue Guo; Anfu Chen; Yujiang Peng; Qianying Gao; Yongxin Zheng; Hanxiong Huang
Journal:  J Mater Sci Mater Med       Date:  2018-11-13       Impact factor: 3.896

3.  Clinical Performance of Extended Depth of Focus (EDOF) Intraocular Lenses - A Retrospective Comparative Study of Mini Well Ready and Symfony.

Authors:  Katarzyna Ewa Nowik; Kamil Nowik; Piotr Kanclerz; Jacek Paweł Szaflik
Journal:  Clin Ophthalmol       Date:  2022-05-26

4.  Three-year incidence of Nd:YAG capsulotomy and posterior capsule opacification and its relationship to monofocal acrylic IOL biomaterial: a UK Real World Evidence study.

Authors:  Paul G Ursell; Mukesh Dhariwal; Katarina Majirska; Frank Ender; Shoshannah Kalson-Ray; Alessandra Venerus; Cristiana Miglio; Christine Bouchet
Journal:  Eye (Lond)       Date:  2018-06-11       Impact factor: 3.775

Review 5.  Factors Affecting Posterior Capsule Opacification in the Development of Intraocular Lens Materials.

Authors:  Grace Cooksley; Joseph Lacey; Marcus K Dymond; Susan Sandeman
Journal:  Pharmaceutics       Date:  2021-06-10       Impact factor: 6.321