Literature DB >> 22935785

Automatic correction of gaps in cerebrovascular segmentations extracted from 3D time-of-flight MRA datasets.

N D Forkert1, A Schmidt-Richberg, J Fiehler, T Illies, D Möller, H Handels, D Säring.   

Abstract

OBJECTIVES: Exact cerebrovascular segmentations are required for several applications in today's clinical routine. A major drawback of typical automatic segmentation methods is the occurrence of gaps within the segmentation. These gaps are typically located at small vessel structures exhibiting low intensities. Manual correction is very time-consuming and not suitable in clinical practice. This work presents a post-processing method for the automatic detection and closing of gaps in cerebrovascular segmentations.
METHODS: In this approach, the 3D centerline is calculated from an available vessel segmentation, which enables the detection of corresponding vessel endpoints. These endpoints are then used to detect possible connections to other 3D centerline voxels with a graph-based approach. After consistency check, reasonable detected paths are expanded to the vessel boundaries using a level set approach and combined with the initial segmentation.
RESULTS: For evaluation purposes, 100 gaps were artificially inserted at non-branching vessels and bifurcations in manual cerebrovascular segmentations derived from ten Time-of-Flight magnetic resonance angiography datasets. The results show that the presented method is capable of detecting 82% of the non-branching vessel gaps and 84% of the bifurcation gaps. The level set segmentation expands the detected connections with 0.42 mm accuracy compared to the initial segmentations. A further evaluation based on 10 real automatic segmentations from the same datasets shows that the proposed method detects 35 additional connections in average per dataset, whereas 92.7% were rated as correct by a medical expert.
CONCLUSION: The presented approach can considerably improve the accuracy of cerebrovascular segmentations and of following analysis outcomes.

Mesh:

Year:  2012        PMID: 22935785     DOI: 10.3414/ME11-02-0037

Source DB:  PubMed          Journal:  Methods Inf Med        ISSN: 0026-1270            Impact factor:   2.176


  4 in total

1.  From bed to bench: bridging from informatics practice to theory: an exploratory analysis.

Authors:  R Haux; C U Lehmann
Journal:  Appl Clin Inform       Date:  2014-10-29       Impact factor: 2.342

2.  Reconnection of Interrupted Curvilinear Structures via Cortically Inspired Completion for Ophthalmologic Images.

Authors:  Jiong Zhang; Erik Bekkers; Da Chen; Tos T J M Berendschot; Jan Schouten; Josien P W Pluim; Yonggang Shi; Behdad Dashtbozorg; Bart M Ter Haar Romeny
Journal:  IEEE Trans Biomed Eng       Date:  2018-05       Impact factor: 4.538

3.  Association of Cardiovascular Risk Factors With MRI Indices of Cerebrovascular Structure and Function and White Matter Hyperintensities in Young Adults.

Authors:  Wilby Williamson; Adam J Lewandowski; Nils D Forkert; Ludovica Griffanti; Thomas W Okell; Jill Betts; Henry Boardman; Timo Siepmann; David McKean; Odaro Huckstep; Jane M Francis; Stefan Neubauer; Renzo Phellan; Mark Jenkinson; Aiden Doherty; Helen Dawes; Eleni Frangou; Christina Malamateniou; Charlie Foster; Paul Leeson
Journal:  JAMA       Date:  2018-08-21       Impact factor: 56.272

4.  Trial of exercise to prevent HypeRtension in young adults (TEPHRA) a randomized controlled trial: study protocol.

Authors:  Wilby Williamson; Odaro J Huckstep; Eleni Frangou; Afifah Mohamed; Cheryl Tan; Maryam Alsharqi; Mariane Bertagnolli; Winok Lapidaire; Julia Newton; Henner Hanssen; Richard McManus; Helen Dawes; Charlie Foster; Adam J Lewandowski; Paul Leeson
Journal:  BMC Cardiovasc Disord       Date:  2018-11-06       Impact factor: 2.298

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.