Literature DB >> 22930944

Possibilities and limitations of implant placement by virtual planning data and surgical guide templates.

H-J Nickenig1, S Eitner, D Rothamel, M Wichmann, J E Zöller.   

Abstract

The use of computer-aided surgical systems for dental implant bed preparation and implant placement results in an average precision within 1 mm of implant position and within 5 degrees of deviation for implant inclination. The accuracy of axis and implant position is significantly more precise with the three-dimensional surgical guide than with the free-hand method. The three-dimensional assessment of the restorative goal (radiopaque simulation of prosthesis with scanning template) allows virtual planning of implants, which enables optimized positioning of implants with surgical guide templates in oral surgery. If there is a clear indication for three-dimensional diagnostics, it should always be checked whether the data can be used as planning data for a surgical guide template, otherwise the chance for guided surgery remains unused. Since uncertainties still exist despite the use of a drilling template, it is recommended that the minimum safety distance from adjacent structures be maintained. The successful use of surgical guide templates requires comprehensive knowledge of and experience in using three-dimensional information for the virtual planning of implant position.

Mesh:

Year:  2012        PMID: 22930944

Source DB:  PubMed          Journal:  Int J Comput Dent        ISSN: 1463-4201            Impact factor:   1.883


  6 in total

1.  Eye-Lid approach for four zigomatic implant placement in the severely reabsorbed maxillae: technical note.

Authors:  Yi-Qun Wu; Feng Wang; Yi-Han Shen; Ming Lin
Journal:  Int J Clin Exp Med       Date:  2015-03-15

Review 2.  In-Office Guided Implant Placement for Prosthetically Driven Implant Surgery.

Authors:  Daryoush Karami; Hamid Reza Alborzinia; Reza Amid; Mahdi Kadkhodazadeh; Navid Yousefi; Sarina Badakhshan
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2016-07-19

3.  Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

Authors:  Nadine Marheineke; Uta Scherer; Martin Rücker; Constantin von See; Björn Rahlf; Nils-Claudius Gellrich; Marcus Stoetzer
Journal:  Clin Oral Investig       Date:  2017-12-17       Impact factor: 3.573

4.  Clinical Outcome of Fully Digital Workflow for Single-Implant-Supported Crowns: A Retrospective Clinical Study.

Authors:  Francesco Gianfreda; Paolo Pesce; Erich Marcano; Valeria Pistilli; Patrizio Bollero; Luigi Canullo
Journal:  Dent J (Basel)       Date:  2022-07-27

5.  Digitally Guided Workflow for the Esthetic and Prosthetic Oral Rehabilitation of a Patient with Excessive Gingival Display: A Case Report.

Authors:  Bandar Alresheedi
Journal:  Clin Cosmet Investig Dent       Date:  2022-09-20

6.  Biomechanics and load resistance of short dental implants: a review of the literature.

Authors:  Istabrak Hasan; Christoph Bourauel; Torsten Mundt; Friedhelm Heinemann
Journal:  ISRN Dent       Date:  2013-05-08
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.