Literature DB >> 22930508

Dried blood spot samples: optimization of commercial EIAs for hepatitis C antibody detection and stability under different storage conditions.

B L C Marques1, C U Brandão, E F Silva, V A Marques, C A Villela-Nogueira, K M R Do Ó, M T de Paula, L L Lewis-Ximenez, E Lampe, L M Villar.   

Abstract

This study was undertaken to optimize and compare the efficiency of two commercial EIAs for anti-HCV detection (HCV Ab Radim, Pomezzia, Italy and ETI-AB-HCVK-4 DiaSorin, Vercelli, Italy), in dried blood spot (DBS) samples. The long-term stability of anti-HCV on DBS samples stored at three environmental conditions was also evaluated at: 2-8 °C, 20-25 °C, and -20 °C. Paired DBS and serum samples were obtained from individuals with or without anti-HCV. The type of elution buffer, sample and conjugate volume, sample incubation time and cut-off values were evaluated. For both EIAs, a larger sample volume was used, and the cut-off value determined by the manufacturer was employed for Radim EIA; however, ROC curve analysis was used for the DiaSorin EIA. The sensitivity and specificity of Radim EIA on DBS were 97.5% and 99.5%, respectively, and of DiaSorin EIA were 88.9% and 98.9%, respectively. Accurate results were obtained for a period of 117 days using DBS samples stored at all storage conditions, but storage at -20 °C resulted in the lowest variation among the absorbance values. Both EIAs demonstrated the same limit of detection (until dilution of 1:10(4) with estimated viral load of 3.1 × 10(-1) UI/ml), but the Radim EIA was associated with the best performance because a low coefficient of variation was observed in the repetition and reproducibility studies. In conclusion, commercial EIAs can be optimized for anti-HCV detection in DBS samples that are extremely stable at different conditions for more than 100 days.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22930508     DOI: 10.1002/jmv.23379

Source DB:  PubMed          Journal:  J Med Virol        ISSN: 0146-6615            Impact factor:   2.327


  12 in total

Review 1.  Emerging trends in paper spray mass spectrometry: Microsampling, storage, direct analysis, and applications.

Authors:  Benjamin S Frey; Deidre E Damon; Abraham K Badu-Tawiah
Journal:  Mass Spectrom Rev       Date:  2019-09-06       Impact factor: 10.946

Review 2.  Update on hepatitis B and C virus diagnosis.

Authors:  Livia Melo Villar; Helena Medina Cruz; Jakeline Ribeiro Barbosa; Cristianne Sousa Bezerra; Moyra Machado Portilho; Letícia de Paula Scalioni
Journal:  World J Virol       Date:  2015-11-12

3.  Reliability of dried blood spot (DBS) cards in antibody measurement: A systematic review.

Authors:  Fahimah Amini; Erick Auma; Yingfen Hsia; Sam Bilton; Tom Hall; Laxmee Ramkhelawon; Paul T Heath; Kirsty Le Doare
Journal:  PLoS One       Date:  2021-03-15       Impact factor: 3.240

4.  A Novel Targeted Screening Tool for Hypogammaglobulinemia: Measurement of Serum Immunoglobulin (IgG, IgM, IgA) Levels from Dried Blood Spots (Ig-DBS Assay).

Authors:  Leman Yel; Christopher J Rabbat; Charlotte Cunningham-Rundles; Jordan S Orange; Troy R Torgerson; James W Verbsky; Yeong Wang; Maoyong Fu; Terry S Robins; Marc S Edwards; Jesper Nymann-Andersen
Journal:  J Clin Immunol       Date:  2015-08-16       Impact factor: 8.317

5.  Dried blood spots--preparing and processing for use in immunoassays and in molecular techniques.

Authors:  Nico Grüner; Oumaima Stambouli; R Stefan Ross
Journal:  J Vis Exp       Date:  2015-03-13       Impact factor: 1.355

Review 6.  Diagnostic accuracy of serological diagnosis of hepatitis C and B using dried blood spot samples (DBS): two systematic reviews and meta-analyses.

Authors:  Berit Lange; Jennifer Cohn; Teri Roberts; Johannes Camp; Jeanne Chauffour; Nina Gummadi; Azumi Ishizaki; Anupriya Nagarathnam; Edouard Tuaillon; Philippe van de Perre; Christine Pichler; Philippa Easterbrook; Claudia M Denkinger
Journal:  BMC Infect Dis       Date:  2017-11-01       Impact factor: 3.090

Review 7.  Dried Blood Spots for Global Health Diagnostics and Surveillance: Opportunities and Challenges.

Authors:  Mark D Lim
Journal:  Am J Trop Med Hyg       Date:  2018-06-28       Impact factor: 2.345

8.  Evaluation of the diagnostic accuracy of laboratory-based screening for hepatitis C in dried blood spot samples: A systematic review and meta-analysis.

Authors:  Sonia Vázquez-Morón; Beatriz Ardizone Jiménez; María A Jiménez-Sousa; José M Bellón; Pablo Ryan; Salvador Resino
Journal:  Sci Rep       Date:  2019-05-13       Impact factor: 4.379

9.  Usefulness of automated assays for detecting hepatitis B and C markers in dried blood spot samples.

Authors:  Livia Melo Villar; Helena Medina Cruz; Raissa Martins Deodato; Juliana Custódio Miguel; Elisangela Ferreira da Silva; Geane Lopes Flores; Lia Laura Lewis-Ximenez
Journal:  BMC Res Notes       Date:  2019-08-20

10.  Evaluation of dried blood spot samples for screening of hepatitis C and human immunodeficiency virus in a real-world setting.

Authors:  Sonia Vázquez-Morón; Pablo Ryan; Beatriz Ardizone-Jiménez; Dolores Martín; Jesus Troya; Guillermo Cuevas; Jorge Valencia; María A Jimenez-Sousa; Ana Avellón; Salvador Resino
Journal:  Sci Rep       Date:  2018-01-30       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.