Clinical outcomes associated with referral-based continuous glucose monitoring using a central standardized interpretation strategy.

Anthony Miele1, Karen Weiland, Kathleen M Dungan.   

Abstract

BACKGROUND: Continuous glucose monitoring (CGM) devices can present a challenge to health providers given the sheer amount of data collected. A referral-based system using a centralized standard interpretation completed by a specialist could highlight the most pertinent information and provide recommendations. SUBJECTS AND METHODS: Professional (retrospective) CGM reports from an outpatient academic endocrinology clinic were formally interpreted by one of two specialists. General recommendations for therapy adjustments were made to each patient's referring provider without a face-to-face visit using only the CGM download and patient logs. Findings were characterized as well as change in hemoglobin A1c (HbA1c) by 6 and 12 months.
RESULTS: Patients with baseline HbA1c values above 8.1% experienced a significant reduction (-0.36 ± 0.80%) at 6 months post-CGM (P = 0.035), whereas those with baseline HbA1c below 8.1% experienced an equally significant increase (0.36 ± 0.83%, P = 0.032), most likely because of interventions that addressed hypoglycemia. Hypoglycemia was common, and unrecognized overnight hypoglycemia lasting over 2 h occurred in 48% of patients. There were no differences in findings or in HbA1c changes among pump compared with non-pump users. In total, 69% of patients had a change in management by the referring provider within 1 month.
CONCLUSIONS: The data suggest that some patients benefited, in the form of reductions in HbA1c, from centralized referral and interpretation of professional CGM regardless of modality of insulin therapy. Considerations for methods to improve coordination with referring providers for follow-up care are needed.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22928614     DOI: 10.1089/dia.2012.0081

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  2 in total

1.  Treatment recommendations following 3-day masked continuous glucose monitoring (CGM) in youth with type 1 diabetes.

Authors:  Lisa E Rasbach; Ashley E Atkins; Kerry M Milaszewski; Joyce Keady; Lisa M Schmidt; Lisa K Volkening; Lori M Laffel
Journal:  J Diabetes Sci Technol       Date:  2014-03-22

2.  Effect of treatment guidance using a retrospective continuous glucose monitoring system on glycaemic control in outpatients with type 2 diabetes mellitus: A randomized controlled trial.

Authors:  Junko Sato; Akio Kanazawa; Fuki Ikeda; Nayumi Shigihara; Minako Kawaguchi; Koji Komiya; Toyoyoshi Uchida; Takeshi Ogihara; Tomoya Mita; Tomoaki Shimizu; Yoshio Fujitani; Hirotaka Watada
Journal:  J Int Med Res       Date:  2015-12-07       Impact factor: 1.671

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.