Literature DB >> 22926895

Dynamic and simultaneous MR measurement of R1 and R2* changes during respiratory challenges for the assessment of blood and tissue oxygenation.

Stefanie Remmele1, Alois M Sprinkart, Andreas Müller, Frank Träber, Marec von Lehe, Jürgen Gieseke, Sebastian Flacke, Winfried A Willinek, Hans H Schild, Julien Sénégas, Jochen Keupp, Petra Mürtz.   

Abstract

This work presents a novel method for the rapid and simultaneous measurement of R1 and R2* relaxation rates. It is based on a dynamic short repetition time steady-state spoiled multigradient-echo sequence and baseline R1 and B1 measurements. The accuracy of the approach was evaluated in simulations and a phantom experiment. The sensitivity and specificity of the method were demonstrated in one volunteer and in four patients with intracranial tumors during carbogen inhalation. We utilized (ΔR2*, ΔR1) scatter plots to analyze the multiparametric response amplitude of each voxel within an area of interest. In normal tissue R2* decreased and R1 increased moderately in response to the elevated blood and tissue oxygenation. A strong negative ΔR2* and ΔR1 response was observed in veins and some tumor areas. Moderate positive ΔR2* and ΔR1 response amplitudes were found in fluid-rich tissue as in cerebrospinal fluid, peritumoral edema, and necrotic areas. The multiparametric approach was shown to increase the specificity and sensitivity of oxygen-enhanced MRI compared to measuring ΔR2* or ΔR1 alone. It is thus expected to provide an optimal tool for the identification of tissue areas with low oxygenation, e.g., in tumors with compromised oxygen supply.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22926895     DOI: 10.1002/mrm.24458

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

Review 1.  Quantitative MR Imaging of Brain Tissue and Brain Pathologies.

Authors:  E Hattingen; A Jurcoane; M Nelles; A Müller; U Nöth; B Mädler; P Mürtz; R Deichmann; H H Schild
Journal:  Clin Neuroradiol       Date:  2015-07-30       Impact factor: 3.649

2.  O2 -sensitive MRI distinguishes brain tumor versus radiation necrosis in murine models.

Authors:  Scott C Beeman; Ying-Bo Shui; Carlos J Perez-Torres; John A Engelbach; Joseph J H Ackerman; Joel R Garbow
Journal:  Magn Reson Med       Date:  2015-07-14       Impact factor: 4.668

3.  The effect of flow on blood oxygen level dependent (R* 2 ) MRI of orthotopic lung tumors.

Authors:  Heling Zhou; Olivier Belzile; Zhang Zhang; Jo Wagner; Chul Ahn; James A Richardson; Debabrata Saha; Rolf A Brekken; Ralph P Mason
Journal:  Magn Reson Med       Date:  2019-01-30       Impact factor: 4.668

4.  Lesion magnetic susceptibility response to hyperoxic challenge: A biomarker for malignant brain tumor microenvironment?

Authors:  Pinar Senay Özbay; Sonja Stieb; Cristina Rossi; Oliver Riesterer; Andreas Boss; Tobias Weiss; Felix Pierre Kuhn; Klaas Paul Pruessmann; Daniel Nanz
Journal:  Magn Reson Imaging       Date:  2017-12-05       Impact factor: 2.546

5.  Brain Morphometry and Longitudinal Relaxation Time of Spontaneously Hypertensive Rats (SHRs) in Early and Intermediate Stages of Hypertension Investigated by 3D VFA-SPGR MRI.

Authors:  Sunil Koundal; Xiaodan Liu; Simon Sanggaard; Kristian Mortensen; Joanna Wardlaw; Maiken Nedergaard; Helene Benveniste; Hedok Lee
Journal:  Neuroscience       Date:  2019-01-26       Impact factor: 3.590

Review 6.  Imaging tumour hypoxia with oxygen-enhanced MRI and BOLD MRI.

Authors:  James P B O'Connor; Simon P Robinson; John C Waterton
Journal:  Br J Radiol       Date:  2019-01-24       Impact factor: 3.039

7.  Dynamic oxygen challenge evaluated by NMR T1 and T2*--insights into tumor oxygenation.

Authors:  Dawen Zhao; Jesús Pacheco-Torres; Rami R Hallac; Derek White; Peter Peschke; Sebastian Cerdán; Ralph P Mason
Journal:  NMR Biomed       Date:  2015-06-08       Impact factor: 4.044

8.  Feasibility and reproducibility of BOLD and TOLD measurements in the liver with oxygen and carbogen gas challenge in healthy volunteers and patients with hepatocellular carcinoma.

Authors:  Octavia Bane; Cecilia Besa; Mathilde Wagner; Niels Oesingmann; Hongfa Zhu; Maria Isabel Fiel; Bachir Taouli
Journal:  J Magn Reson Imaging       Date:  2015-09-28       Impact factor: 4.813

9.  Developing oxygen-enhanced magnetic resonance imaging as a prognostic biomarker of radiation response.

Authors:  Derek A White; Zhang Zhang; Li Li; Jeni Gerberich; Strahinja Stojadinovic; Peter Peschke; Ralph P Mason
Journal:  Cancer Lett       Date:  2016-06-03       Impact factor: 8.679

10.  Correlations of noninvasive BOLD and TOLD MRI with pO2 and relevance to tumor radiation response.

Authors:  Rami R Hallac; Heling Zhou; Rajesh Pidikiti; Kwang Song; Strahinja Stojadinovic; Dawen Zhao; Timothy Solberg; Peter Peschke; Ralph P Mason
Journal:  Magn Reson Med       Date:  2013-06-27       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.