BACKGROUND: Integrated operation systems were developed for centralization and easy control of all components within the operating room (OR). These systems represent central units that use communication technology to connect and control various components of the OR. Voice control that is independent of the speaker has been a pioneering innovation in the central control of different OR components. The aim of the present study was to evaluate the utility of two voice-activated control systems, the Siemens Integrated OR System (SIOS, Siemens Medical Solutions, Siemens AG) and the OR1 (Karl Storz GmbH & Co. KG), for delivery of commands to specific OR equipment.
METHODS: To compare the two systems, actions such as adjusting the operating table, increasing gas pressure, switching on the video recorder, and controlling the endolight source were defined according to a study protocol. These actions were to be executed by test persons through speech and manual control after a suitable training period. The parameters evaluated were training time, time to execute each action, number of repeated commands, and number of functional errors.
RESULTS: Seventy-four test persons from five nations were selected to participate. The numbers of repeated commands and functional errors differed significantly between systems in all user groups in favor of the SIOS (mean repeated commands for surgeons: SIOS, 2.4; OR1, 14.7, p < 0.0001).
CONCLUSION: The SIOS voice control was more effective and more reliable than that of the OR1. Importantly, unlike the OR1, the SIOS produced no functional errors. The appropriate conditions for greater acceptance of these systems must be considered, together with additional technical improvements and possible combinations of advantages of the available systems.

Entities:  

Mesh:

Year:  2012        PMID: 22926891     DOI: 10.1007/s00464-012-2488-9

Source DB:  PubMed          Journal:  Surg Endosc        ISSN: 0930-2794            Impact factor:   4.584


  11 in total

1.  Minimally invasive and robotic surgery.

Authors:  M J Mack
Journal:  JAMA       Date:  2001-02-07       Impact factor: 56.272

Review 2.  [Robotics. A new dimension in otorhinolaryngology?].

Authors:  P A Federspil; J Stallkamp; P K Plinkert
Journal:  HNO       Date:  2001-07       Impact factor: 1.284

3.  Photography through the fiber gastroscope.

Authors:  B I HIRSCHOWITZ
Journal:  Am J Dig Dis       Date:  1963-05

4.  Utility of a voice-activated system in minimally invasive surgery.

Authors:  Ibrahim Abdelkader Salama; Steven D Schwaitzberg
Journal:  J Laparoendosc Adv Surg Tech A       Date:  2005-10       Impact factor: 1.878

5.  Laparoscopy-assisted sigmoid resection.

Authors:  D L Fowler; S A White
Journal:  Surg Laparosc Endosc       Date:  1991-09

6.  Evaluation of voice control, touch panel control and assistant control during steering of an endoscope.

Authors:  Marius M Punt; Coen N Stefels; Cornelis A Grimbergen; Jenny Dankelman
Journal:  Minim Invasive Ther Allied Technol       Date:  2005       Impact factor: 2.442

7.  Laparoscopic herniorrhaphy.

Authors:  J D Corbitt
Journal:  Surg Laparosc Endosc       Date:  1991-03

8.  Man-machine interfaces in computer assisted surgery.

Authors:  H Visarius; J Gong; C Scheer; S Haralamb; L P Nolte
Journal:  Comput Aided Surg       Date:  1997

9.  Electronic endoscopy of the gastrointestinal tract. Initial experience with a new type of endoscope that has no fiberoptic bundle for imaging.

Authors:  M Classen; J Phillip
Journal:  Endoscopy       Date:  1984-01       Impact factor: 10.093

Review 10.  Robotics in colorectal surgery.

Authors:  J Hance; T Rockall; A Darzi
Journal:  Dig Surg       Date:  2004-10-06       Impact factor: 2.588

View more
  5 in total

Review 1.  Touchless interaction with software in interventional radiology and surgery: a systematic literature review.

Authors:  André Mewes; Bennet Hensen; Frank Wacker; Christian Hansen
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-09-19       Impact factor: 2.924

Review 2.  Computer-assisted abdominal surgery: new technologies.

Authors:  H G Kenngott; M Wagner; F Nickel; A L Wekerle; A Preukschas; M Apitz; T Schulte; R Rempel; P Mietkowski; F Wagner; A Termer; Beat P Müller-Stich
Journal:  Langenbecks Arch Surg       Date:  2015-02-21       Impact factor: 3.445

3.  Implementation of integrated operating rooms: how much time is saved and how do medical staff experience the upgrading? A mixed methods study in Denmark.

Authors:  Kathrine Carstensen; Emma Kejser Jensen; Mads Lænsø Madsen; Anne Marie Ladehoff Thomsen; Claus Løvschall; Nasrin Tayyari Dehbarez; Bettina Wulff Risør
Journal:  BMJ Open       Date:  2020-07-29       Impact factor: 2.692

4.  Electromagnetic Navigation Bronchoscopy Integrated Non-intubated Uniportal VATS in Localization and Resection of Pulmonary Nodules.

Authors:  Rui Wang; Yu Jiang; Jiaxi He; Yuechun Lin; Zhufeng Wang; Shuben Li
Journal:  Front Surg       Date:  2022-04-05

5.  Three-dimensional holographic visualization of high-resolution myocardial scar on HoloLens.

Authors:  Jihye Jang; Cory M Tschabrunn; Michael Barkagan; Elad Anter; Bjoern Menze; Reza Nezafat
Journal:  PLoS One       Date:  2018-10-08       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.