Abstract

In dynamic MRI, spatial and temporal parallel imaging can be exploited to reduce scan time. Real-time reconstruction enables immediate visualization during the scan. Commonly used view-sharing techniques suffer from limited temporal resolution, and many of the more advanced reconstruction methods are either retrospective, time-consuming, or both. A Kalman filter model capable of real-time reconstruction can be used to increase the spatial and temporal resolution in dynamic MRI reconstruction. The original study describing the use of the Kalman filter in dynamic MRI was limited to non-Cartesian trajectories because of a limitation intrinsic to the dynamic model used in that study. Here the limitation is overcome, and the model is applied to the more commonly used Cartesian trajectory with fast reconstruction. Furthermore, a combination of the Kalman filter model with Cartesian parallel imaging is presented to further increase the spatial and temporal resolution and signal-to-noise ratio. Simulations and experiments were conducted to demonstrate that the Kalman filter model can increase the temporal resolution of the image series compared with view-sharing techniques and decrease the spatial aliasing compared with TGRAPPA. The method requires relatively little computation, and thus is suitable for real-time reconstruction.
Copyright © 2012 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2012        PMID: 22926804      PMCID: PMC3536913          DOI: 10.1002/mrm.24375

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Adaptive sensitivity encoding incorporating temporal filtering (TSENSE).

Authors:  P Kellman; F H Epstein; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-05       Impact factor: 4.668

2.  A reduced field-of-view method to increase temporal resolution or reduce scan time in cine MRI.

Authors:  B Madore; J O Fredrickson; M T Alley; N J Pelc
Journal:  Magn Reson Med       Date:  2000-04       Impact factor: 4.668

3.  Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.

Authors:  B Madore; G H Glover; N J Pelc
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

4.  Sensitivity profiles from an array of coils for encoding and reconstruction in parallel (SPACE RIP).

Authors:  W E Kyriakos; L P Panych; D F Kacher; C F Westin; S M Bao; R V Mulkern; F A Jolesz
Journal:  Magn Reson Med       Date:  2000-08       Impact factor: 4.668

5.  Comparison of temporal filtering methods for dynamic contrast MRI myocardial perfusion studies.

Authors:  E V R Di Bella; Y J Wu; A L Alexander; D L Parker; D Green; C J McGann
Journal:  Magn Reson Med       Date:  2003-05       Impact factor: 4.668

6.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

7.  Noquist: reduced field-of-view imaging by direct Fourier inversion.

Authors:  Marijn E Brummer; David Moratal-Pérez; Chung-Yi Hong; Roderic I Pettigrew; José Millet-Roig; W Thomas Dixon
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

8.  k-t BLAST and k-t SENSE: dynamic MRI with high frame rate exploiting spatiotemporal correlations.

Authors:  Jeffrey Tsao; Peter Boesiger; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2003-11       Impact factor: 4.668

9.  "PINOT": time-resolved parallel magnetic resonance imaging with a reduced dynamic field of view.

Authors:  Lei Hou Hamilton; Javier Acebron Fabregat; David Moratal; Senthil Ramamurthy; Stamatios Lerakis; W James Parks; Denver Sallee; Marijn E Brummer
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

10.  Theory of high-speed MR imaging of the human heart with the selective line acquisition mode.

Authors:  W G Rehwald; R J Kim; O P Simonetti; G Laub; R M Judd
Journal:  Radiology       Date:  2001-08       Impact factor: 11.105

View more
  3 in total

1.  Direct and accelerated parameter mapping using the unscented Kalman filter.

Authors:  Li Zhao; Xue Feng; Craig H Meyer
Journal:  Magn Reson Med       Date:  2015-06-03       Impact factor: 4.668

2.  Assessment of velopharyngeal function with dual-planar high-resolution real-time spiral dynamic MRI.

Authors:  Xue Feng; Silvia S Blemker; Josh Inouye; Catherine M Pelland; Li Zhao; Craig H Meyer
Journal:  Magn Reson Med       Date:  2018-03-05       Impact factor: 4.668

3.  Motion-compensated compressed sensing for dynamic contrast-enhanced MRI using regional spatiotemporal sparsity and region tracking: block low-rank sparsity with motion-guidance (BLOSM).

Authors:  Xiao Chen; Michael Salerno; Yang Yang; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2013-11-18       Impact factor: 4.668

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.