Literature DB >> 22922621

Reproducibility of quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound.

Thomas P Gauthier1, Aun Muhammad, Harpreet S Wasan, Paul D Abel, Edward L S Leen.   

Abstract

OBJECTIVES: The aim of this clinical study was to evaluate the reproducibility of quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound.
METHODS: Fifteen patients with colorectal liver metastases and 5 volunteers were studied. The hepatic artery proper and the portal vein were imaged simultaneously with dynamic contrast-enhanced ultrasound. The examination was repeated with 2 different contrast bolus volumes (1.2 and 2.4 mL), and time-intensity curves were formed from dynamic contrast-enhanced ultrasound image loops. The rise time, peak intensity, and wash-in slope were derived from hepatic artery and portal vein time-intensity curves. Inter-reader, intra-reader, and inter-scan agreement was assessed by 2 independent readers. Quantitative (intraclass correlation coefficients and coefficients of variation [CVs]) and qualitative (Landis and Koch classification) analyses were performed.
RESULTS: Intra-reader and inter-reader agreement was "almost perfect" for the hepatic artery (CV, 10%-15% and 8%-9%, respectively), portal vein (CV, 5%-8% and 6%-12%), and hepatic artery/portal vein ratio (CV, 8%-14% and 10%-15%) measurements of 3 all studied parameters. In contrast, inter-scan agreement was only "slight" to "moderate" (CV, 25%-27%) and "fair" to "moderate" (CV, 19%-24%) for rise time and peak intensity measurements in the hepatic artery and portal vein, respectively.
CONCLUSIONS: Quantitative assessment of altered hepatic hemodynamics with dynamic contrast-enhanced ultrasound is reproducible provided that measurements in the hepatic artery are normalized by those in the portal vein.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22922621     DOI: 10.7863/jum.2012.31.9.1413

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  4 in total

1.  Correlation of ultrasound contrast agent derived blood flow parameters with immunohistochemical angiogenesis markers in murine xenograft tumor models.

Authors:  John R Eisenbrey; Christian C Wilson; Raymond J Ro; Traci B Fox; Ji-Bin Liu; See-Ying Chiou; Flemming Forsberg
Journal:  Ultrasonics       Date:  2013-04-12       Impact factor: 2.890

2.  The quantitative evaluation of contrast-enhanced ultrasound in the differentiation of small renal cell carcinoma subtypes and angiomyolipoma.

Authors:  Hui Liu; Hongli Cao; Lin Chen; Liang Fang; Yingchun Liu; Jia Zhan; Xuehong Diao; Yue Chen
Journal:  Quant Imaging Med Surg       Date:  2022-01

3.  Use of Caval Subtraction 2D Phase-Contrast MR Imaging to Measure Total Liver and Hepatic Arterial Blood Flow: Preclinical Validation and Initial Clinical Translation.

Authors:  Manil D Chouhan; Rajeshwar P Mookerjee; Alan Bainbridge; Simon Walker-Samuel; Nathan Davies; Steve Halligan; Mark F Lythgoe; Stuart A Taylor
Journal:  Radiology       Date:  2016-05-12       Impact factor: 11.105

4.  Repeatability and reproducibility of quantitative contrast-enhanced ultrasonography for assessing duodenal perfusion in healthy dogs.

Authors:  Khoirun Nisa; Sue Yee Lim; Masayoshi Shinohara; Noriyuki Nagata; Kazuyoshi Sasaoka; Angkhana Dermlim; Rommaneeya Leela-Arporn; Tomoya Morita; Nozomu Yokoyama; Tatsuyuki Osuga; Noboru Sasaki; Keitaro Morishita; Kensuke Nakamura; Hiroshi Ohta; Mitsuyoshi Takiguchi
Journal:  J Vet Med Sci       Date:  2017-08-05       Impact factor: 1.267

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.