Literature DB >> 22920802

Increasing local blood flow by warming the application site: beneficial effects on postprandial glycemic excursions.

Guido Freckmann1, Stefan Pleus, Cornelia Haug, Gabriel Bitton, Ron Nagar.   

Abstract

The absorption profile of rapid-acting insulin analogs delivered subcutaneously is slow compared with physiological insulin. Shorter time to peak and shorter duration of insulin action are important steps toward reducing high postprandial blood glucose concentrations in diabetes therapy and are critical for the development of a closed-loop insulin delivery system. Many attempts have been made to develop more rapid-acting insulins. Since the 1950s, different approaches, such as jet injectors and sprinkler needles, which try to increase the absorption areas of injected insulin, have been developed; however, none of them are commonly used in diabetes therapy. Massage and heat increase tissue blood perfusion and, thereby, the absorption of subcutaneously applied insulin. The main focus of this article is a novel device that allows local application of heat to human skin. The device can be connected to a regular insulin pump. This device could demonstrate a significant effect on insulin absorption and postprandial glucose excursions in multiple clinical trials.
© 2012 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22920802      PMCID: PMC3440147          DOI: 10.1177/193229681200600407

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  24 in total

1.  The pharmacokinetics of transdermal fentanyl delivered with and without controlled heat.

Authors:  Michael A Ashburn; L Lazarre Ogden; Jie Zhang; Georgette Love; Susan V Basta
Journal:  J Pain       Date:  2003-08       Impact factor: 5.820

2.  A recombinant human enzyme for enhanced interstitial transport of therapeutics.

Authors:  L H Bookbinder; A Hofer; M F Haller; M L Zepeda; G-A Keller; J E Lim; T S Edgington; H M Shepard; J S Patton; G I Frost
Journal:  J Control Release       Date:  2006-06-07       Impact factor: 9.776

3.  Dose-response relationship of insulin glulisine in subjects with type 1 diabetes.

Authors:  Reinhard H A Becker; Annke D Frick; Leszek Nosek; Lutz Heinemann; Klaus Rave
Journal:  Diabetes Care       Date:  2007-08-03       Impact factor: 19.112

4.  Clinical performance of a device that applies local heat to the insulin infusion site: a crossover study.

Authors:  Guido Freckmann; Stefan Pleus; Antje Westhoff; Lars G Krinelke; Andreas Buhr; Nina Jendrike; Cornelia Haug
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

5.  The ability of different areas of the skin to absorb heat from a locally applied heat source: the impact of diabetes.

Authors:  Jerrold Petrofsky; Dominic Paluso; Devyn Anderson; Kristin Swan; Faris Alshammari; Vahishta Katrak; Vengatesh Murugesan; Akshay N Hudlikar; Tirupathi Chindam; Moxi Trivedi; Haneul Lee; Neha Goraksh; Jong Eun Yim
Journal:  Diabetes Technol Ther       Date:  2011-02-03       Impact factor: 6.118

6.  Nitric oxide and neurally mediated regulation of skin blood flow during local heating.

Authors:  C T Minson; L T Berry; M J Joyner
Journal:  J Appl Physiol (1985)       Date:  2001-10

Review 7.  Variability of insulin absorption and insulin action.

Authors:  Lutz Heinemann
Journal:  Diabetes Technol Ther       Date:  2002       Impact factor: 6.118

8.  Timing of meal insulin boluses to achieve optimal postprandial glycemic control in patients with type 1 diabetes.

Authors:  Erin Cobry; Kim McFann; Laurel Messer; Victoria Gage; Brandon VanderWel; Lauren Horton; H Peter Chase
Journal:  Diabetes Technol Ther       Date:  2010-03       Impact factor: 6.118

9.  Limitations of conventional methods of self-monitoring of blood glucose: lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes.

Authors:  E Boland; T Monsod; M Delucia; C A Brandt; S Fernando; W V Tamborlane
Journal:  Diabetes Care       Date:  2001-11       Impact factor: 19.112

10.  Effect of a local heating device on insulin and glucose pharmacokinetic profiles in an open-label, randomized, two-period, one-way crossover study in patients with type 1 diabetes using continuous subcutaneous insulin infusion.

Authors:  Itamar Raz; Ram Weiss; Yevgeny Yegorchikov; Gabriel Bitton; Ron Nagar; Benny Pesach
Journal:  Clin Ther       Date:  2009-05       Impact factor: 3.393

View more
  5 in total

1.  Subcutaneous Insulin Administration: Sufficient Progress or Ongoing Need?

Authors:  Ronald J Pettis; Douglas Muchmore; Lutz Heinemann
Journal:  J Diabetes Sci Technol       Date:  2018-12-07

2.  Improved Postprandial Glucose Control Using the InsuPad Device in Insulin-Treated Type 2 Diabetes: Injection Site Warming to Improve Glycemic Control.

Authors:  Itamar Raz; Gabriel Bitton; Dmitry Feldman; Tal Alon; Andreas Pfutzner; William V Tamborlane
Journal:  J Diabetes Sci Technol       Date:  2015-04-16

Review 3.  Ultrafast-acting insulins: state of the art.

Authors:  Lutz Heinemann; Douglas B Muchmore
Journal:  J Diabetes Sci Technol       Date:  2012-07-01

Review 4.  Insulin delivery methods: Past, present and future.

Authors:  Rima B Shah; Manhar Patel; David M Maahs; Viral N Shah
Journal:  Int J Pharm Investig       Date:  2016 Jan-Mar

Review 5.  Photoplethysmogram Analysis and Applications: An Integrative Review.

Authors:  Junyung Park; Hyeon Seok Seok; Sang-Su Kim; Hangsik Shin
Journal:  Front Physiol       Date:  2022-03-01       Impact factor: 4.566

  5 in total