Literature DB >> 22915363

NIST/ISAC standardization study: variability in assignment of intensity values to fluorescence standard beads and in cross calibration of standard beads to hard dyed beads.

Robert A Hoffman1, Lili Wang, Martin Bigos, John P Nolan.   

Abstract

Results from a standardization study cosponsored by the International Society for Advancement of Cytometry (ISAC) and the US National Institute of Standards and Technology (NIST) are reported. The study evaluated the variability of assigning intensity values to fluorophore standard beads by bead manufacturers and the variability of cross calibrating the standard beads to stained polymer beads (hard-dyed beads) using different flow cytometers. Hard dyed beads are generally not spectrally matched to the fluorophores used to stain cells, and spectral response varies among flow cytometers. Thus if hard dyed beads are used as fluorescence calibrators, one expects calibration for specific fluorophores (e.g., FITC or PE) to vary among different instruments. Using standard beads surface-stained with specific fluorophores (FITC, PE, APC, and Pacific Blue™), the study compared the measured intensity of fluorophore standard beads to that of hard dyed beads through cross calibration on 133 different flow cytometers. Using robust CV as a measure of variability, the variation of cross calibrated values was typically 20% or more for a particular hard dyed bead in a specific detection channel. The variation across different instrument models was often greater than the variation within a particular instrument model. As a separate part of the study, NIST and four bead manufacturers used a NIST supplied protocol and calibrated fluorophore solution standards to assign intensity values to the fluorophore beads. Values assigned to the reference beads by different groups varied by orders of magnitude in most cases, reflecting differences in instrumentation used to perform the calibration. The study concluded that the use of any spectrally unmatched hard dyed bead as a general fluorescence calibrator must be verified and characterized for every particular instrument model. Close interaction between bead manufacturers and NIST is recommended to have reliable and uniformly assigned fluorescence standard beads.
Copyright © 2012 International Society for Advancement of Cytometry.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22915363     DOI: 10.1002/cyto.a.22086

Source DB:  PubMed          Journal:  Cytometry A        ISSN: 1552-4922            Impact factor:   4.355


  12 in total

Review 1.  Spectral flow cytometry.

Authors:  John P Nolan; Danilo Condello
Journal:  Curr Protoc Cytom       Date:  2013-01

2.  FlowCal: A User-Friendly, Open Source Software Tool for Automatically Converting Flow Cytometry Data from Arbitrary to Calibrated Units.

Authors:  Sebastian M Castillo-Hair; John T Sexton; Brian P Landry; Evan J Olson; Oleg A Igoshin; Jeffrey J Tabor
Journal:  ACS Synth Biol       Date:  2016-05-12       Impact factor: 5.110

3.  Cas9 gRNA engineering for genome editing, activation and repression.

Authors:  Samira Kiani; Alejandro Chavez; Marcelle Tuttle; Richard N Hall; Raj Chari; Dmitry Ter-Ovanesyan; Jason Qian; Benjamin W Pruitt; Jacob Beal; Suhani Vora; Joanna Buchthal; Emma J K Kowal; Mohammad R Ebrahimkhani; James J Collins; Ron Weiss; George Church
Journal:  Nat Methods       Date:  2015-09-07       Impact factor: 28.547

Review 4.  Bridging the gap: a roadmap to breaking the biological design barrier.

Authors:  Jacob Beal
Journal:  Front Bioeng Biotechnol       Date:  2015-01-20

5.  Improved Flow Cytometric Light Scatter Detection of Submicron-Sized Particles by Reduction of Optical Background Signals.

Authors:  Ger J A Arkesteijn; Estefanía Lozano-Andrés; Sten F W M Libregts; Marca H M Wauben
Journal:  Cytometry A       Date:  2020-05-27       Impact factor: 4.355

Review 6.  Advances of Single-Cell Protein Analysis.

Authors:  Lixing Liu; Deyong Chen; Junbo Wang; Jian Chen
Journal:  Cells       Date:  2020-05-20       Impact factor: 6.600

7.  Quantification of bacterial fluorescence using independent calibrants.

Authors:  Jacob Beal; Traci Haddock-Angelli; Geoff Baldwin; Markus Gershater; Ari Dwijayanti; Marko Storch; Kim de Mora; Meagan Lizarazo; Randy Rettberg
Journal:  PLoS One       Date:  2018-06-21       Impact factor: 3.240

8.  Robust estimation of bacterial cell count from optical density.

Authors:  Jacob Beal; Natalie G Farny; Traci Haddock-Angelli; Vinoo Selvarajah; Geoff S Baldwin; Russell Buckley-Taylor; Markus Gershater; Daisuke Kiga; John Marken; Vishal Sanchania; Abigail Sison; Christopher T Workman
Journal:  Commun Biol       Date:  2020-09-17

9.  Saturation monitoring of VX15/2503, a novel semaphorin 4D-specific antibody, in clinical trials.

Authors:  Terrence L Fisher; Jennifer Seils; Christine Reilly; Virginia Litwin; Lisa Green; Janelle Salkowitz-Bokal; Robin Walsh; Sarah Harville; John E Leonard; Ernest Smith; Maurice Zauderer
Journal:  Cytometry B Clin Cytom       Date:  2015-12-24       Impact factor: 3.058

10.  Reproducibility of Fluorescent Expression from Engineered Biological Constructs in E. coli.

Authors:  Jacob Beal; Traci Haddock-Angelli; Markus Gershater; Kim de Mora; Meagan Lizarazo; Jim Hollenhorst; Randy Rettberg
Journal:  PLoS One       Date:  2016-03-03       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.