Literature DB >> 22908991

Solid phase DNA extraction with a flexible bead-packed microfluidic device to detect methicillin-resistant Staphylococcus aureus in nasal swabs.

Kyu-Youn Hwang1, Sung Hong Kwon, Sun-Ok Jung, Kak Namkoong, Won-Jong Jung, Joon-Ho Kim, Kahp-Yang Suh, Nam Huh.   

Abstract

We have developed a bead-packed microfluidic device with a built-in flexible wall to automate extraction of nucleic acids from methicillin-resistant Staphylococcus aureus (MRSA) in nasal swabs. The flexible polydimethylsiloxane (PDMS) membrane was designed to manipulate the surface-to-volume ratio (SVR) of bead-packed chambers in the range of 0.05 to 0.15 (μm(-1)) for a typical solid phase extraction protocol composed of binding, washing, and eluting. In particular, the pneumatically assisted close packing of beads led to an invariant SVR (0.15 μm(-1)) even with different bead amounts (10-16 mg), which allowed for consistent operation of the device and improved capture efficiency for bacteria cells. Furthermore, vigorous mixing by asynchronous membrane vibration enabled ca. 90% DNA recovery with ca. 10 μL of liquid solution from the captured cells on the bead surfaces. The full processes to detect MRSA in nasal swabs, i.e., nasal swab collection, prefiltration, on-chip DNA extraction, and real-time polymerase chain reaction (PCR) amplification, were successfully constructed and carried out to validate the capability to detect MRSA in nasal swab samples. This flexible microdevice provided an excellent analytical PCR detection sensitivity of ca. 61 CFU/swab with 95% confidence interval, which turned out to be higher than or similar to that of the commercial DNA-based MRSA detection techniques. This excellent performance would be attributed to the capability of the flexible bead-packed microdevice to enrich the analyte from a large initial sample (e.g., 1 mL) into a microscale volume of eluate (e.g., 10 μL). The proposed microdevice will find many applications as a solid phase extraction method toward various sample-to-answer systems.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22908991     DOI: 10.1021/ac3016533

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Detecting and tracking nosocomial methicillin-resistant Staphylococcus aureus using a microfluidic SERS biosensor.

Authors:  Xiaonan Lu; Derrick R Samuelson; Yuhao Xu; Hongwei Zhang; Shuo Wang; Barbara A Rasco; Jie Xu; Michael E Konkel
Journal:  Anal Chem       Date:  2013-02-01       Impact factor: 6.986

2.  Comparison between a chimeric lysin ClyH and other enzymes for extracting DNA to detect methicillin resistant Staphylococcus aureus by quantitative PCR.

Authors:  Yuanyuan Hu; Hang Yang; Jing Wang; Yun Zhang; Junping Yu; Hongping Wei
Journal:  World J Microbiol Biotechnol       Date:  2015-11-23       Impact factor: 3.312

Review 3.  Towards Multiplex Molecular Diagnosis-A Review of Microfluidic Genomics Technologies.

Authors:  Ismail Hussain Kamal Basha; Eric Tatt Wei Ho; Caffiyar Mohamed Yousuff; Nor Hisham Bin Hamid
Journal:  Micromachines (Basel)       Date:  2017-08-30       Impact factor: 2.891

4.  Evaluation of a microfluidic chip system for preparation of bacterial DNA from swabs, air, and surface water samples.

Authors:  Sandra Julich; Helmut Hotzel; Claudia Gärtner; Daniel Trouchet; Marwa Fawzy El Metwaly Ahmed; Nicole Kemper; Herbert Tomaso
Journal:  Biologicals       Date:  2016-08-09       Impact factor: 1.856

  4 in total