Literature DB >> 22906792

Population-based input function and image-derived input function for [¹¹C](R)-rolipram PET imaging: methodology, validation and application to the study of major depressive disorder.

Paolo Zanotti-Fregonara1, Christina S Hines, Sami S Zoghbi, Jeih-San Liow, Yi Zhang, Victor W Pike, Wayne C Drevets, Alan G Mallinger, Carlos A Zarate, Masahiro Fujita, Robert B Innis.   

Abstract

UNLABELLED: Quantitative PET studies of neuroreceptor tracers typically require that arterial input function be measured. The aim of this study was to explore the use of a population-based input function (PBIF) and an image-derived input function (IDIF) for [(11)C](R)-rolipram kinetic analysis, with the goal of reducing - and possibly eliminating - the number of arterial blood samples needed to measure parent radioligand concentrations.
METHODS: A PBIF was first generated using [(11)C](R)-rolipram parent time-activity curves from 12 healthy volunteers (Group 1). Both invasive (blood samples) and non-invasive (body weight, body surface area, and lean body mass) scaling methods for PBIF were tested. The scaling method that gave the best estimate of the Logan-V(T) values was then used to determine the test-retest variability of PBIF in Group 1 and then prospectively applied to another population of 25 healthy subjects (Group 2), as well as to a population of 26 patients with major depressive disorder (Group 3). Results were also compared to those obtained with an image-derived input function (IDIF) from the internal carotid artery. In some subjects, we measured arteriovenous differences in [(11)C](R)-rolipram concentration to see whether venous samples could be used instead of arterial samples. Finally, we assessed the ability of IDIF and PBIF to discriminate depressed patients (MDD) and healthy subjects.
RESULTS: Arterial blood-scaled PBIF gave better results than any non-invasive scaling technique. Excellent results were obtained when the blood-scaled PBIF was prospectively applied to the subjects in Group 2 (V(T) ratio 1.02±0.05; mean±SD) and Group 3 (V(T) ratio 1.03±0.04). Equally accurate results were obtained for two subpopulations of subjects drawn from Groups 2 and 3 who had very differently shaped (i.e. "flatter" or "steeper") input functions compared to PBIF (V(T) ratio 1.07±0.04 and 0.99±0.04, respectively). Results obtained via PBIF were equivalent to those obtained via IDIF (V(T) ratio 0.99±0.05 and 1.00±0.04 for healthy subjects and MDD patients, respectively). Retest variability of PBIF was equivalent to that obtained with full input function and IDIF (14.5%, 15.2%, and 14.1%, respectively). Due to [(11)C](R)-rolipram arteriovenous differences, venous samples could not be substituted for arterial samples. With both IDIF and PBIF, depressed patients had a 20% reduction in [(11)C](R)-rolipram binding as compared to control (two-way ANOVA: p=0.008 and 0.005, respectively). These results were almost equivalent to those obtained using 23 arterial samples.
CONCLUSION: Although some arterial samples are still necessary, both PBIF and IDIF are accurate and precise alternatives to full arterial input function for [(11)C](R)-rolipram PET studies. Both techniques give accurate results with low variability, even for clinically different groups of subjects and those with very differently shaped input functions. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22906792      PMCID: PMC3472081          DOI: 10.1016/j.neuroimage.2012.08.007

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  48 in total

1.  Extraction of a plasma time-activity curve from dynamic brain PET images based on independent component analysis.

Authors:  Mika Naganawa; Yuichi Kimura; Kenji Ishii; Keiichi Oda; Kiichi Ishiwata; Ayumu Matani
Journal:  IEEE Trans Biomed Eng       Date:  2005-02       Impact factor: 4.538

2.  Quantification of brain phosphodiesterase 4 in rat with (R)-[11C]Rolipram-PET.

Authors:  Masahiro Fujita; Sami S Zoghbi; Matthew S Crescenzo; Jinsoo Hong; John L Musachio; Jian-Qiang Lu; Jeih-San Liow; Nicholas Seneca; Dnyanesh N Tipre; Vanessa L Cropley; Masao Imaizumi; Antony D Gee; Jurgen Seidel; Michael V Green; Victor W Pike; Robert B Innis
Journal:  Neuroimage       Date:  2005-07-15       Impact factor: 6.556

3.  Quantification method in [18F]fluorodeoxyglucose brain positron emission tomography using independent component analysis.

Authors:  Kuan-Hao Su; Liang-Chih Wu; Ren-Shian Liu; Shih-Jen Wang; Jyh-Cheng Chen
Journal:  Nucl Med Commun       Date:  2005-11       Impact factor: 1.690

4.  Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function.

Authors:  K Chen; D Bandy; E Reiman; S C Huang; M Lawson; D Feng; L S Yun; A Palant
Journal:  J Cereb Blood Flow Metab       Date:  1998-07       Impact factor: 6.200

5.  Evaluation of two population-based input functions for quantitative neurological FDG PET studies.

Authors:  S Eberl; A R Anayat; R R Fulton; P K Hooper; M J Fulham
Journal:  Eur J Nucl Med       Date:  1997-03

6.  Noninvasive measurement of cerebral metabolic rate of glucose using standardized input function.

Authors:  T Tsuchida; N Sadato; Y Yonekura; S Nakamura; N Takahashi; K Sugimoto; A Waki; K Yamamoto; N Hayashi; Y Ishii
Journal:  J Nucl Med       Date:  1999-09       Impact factor: 10.057

7.  No evidence of altered in vivo benzodiazepine receptor binding in schizophrenia.

Authors:  A Abi-Dargham; M Laruelle; J Krystal; C D'Souza; S Zoghbi; R M Baldwin; J Seibyl; O Mawlawi; G de Erasquin; D Charney; R B Innis
Journal:  Neuropsychopharmacology       Date:  1999-06       Impact factor: 7.853

8.  Evaluation of the use of a standard input function for compartment analysis of [123I]iomazenil data: factors influencing the quantitative results.

Authors:  Yujiro Seike; Kazuo Hashikawa; Naohiko Oku; Hiroshi Moriwaki; Haruko Yamamoto; Kazuki Fukuchi; Yoshiyuki Watanabe; Masayasu Matsumoto; Masatsugu Hori; Tsunehiko Nishimura
Journal:  Ann Nucl Med       Date:  2004-10       Impact factor: 2.668

9.  A method to quantitate cerebral blood flow using a rotating gamma camera and iodine-123 iodoamphetamine with one blood sampling.

Authors:  H Iida; H Itoh; P M Bloomfield; M Munaka; S Higano; M Murakami; A Inugami; S Eberl; Y Aizawa; I Kanno
Journal:  Eur J Nucl Med       Date:  1994-10

Review 10.  Lean body mass as a predictor of drug dosage. Implications for drug therapy.

Authors:  D J Morgan; K M Bray
Journal:  Clin Pharmacokinet       Date:  1994-04       Impact factor: 6.447

View more
  23 in total

1.  Dynamic PET of human liver inflammation: impact of kinetic modeling with optimization-derived dual-blood input function.

Authors:  Guobao Wang; Michael T Corwin; Kristin A Olson; Ramsey D Badawi; Souvik Sarkar
Journal:  Phys Med Biol       Date:  2018-07-24       Impact factor: 3.609

2.  Voxelwise quantification of [(11)C](R)-rolipram PET data: a comparison between model-based and data-driven methods.

Authors:  Gaia Rizzo; Mattia Veronese; Paolo Zanotti-Fregonara; Alessandra Bertoldo
Journal:  J Cereb Blood Flow Metab       Date:  2013-03-20       Impact factor: 6.200

3.  PET radiopharmaceuticals for probing enzymes in the brain.

Authors:  Jason P Holland; Paul Cumming; Neil Vasdev
Journal:  Am J Nucl Med Mol Imaging       Date:  2013-04-09

Review 4.  Considerations in the Development of Reversibly Binding PET Radioligands for Brain Imaging.

Authors:  Victor W Pike
Journal:  Curr Med Chem       Date:  2016       Impact factor: 4.530

5.  Substitution of venous for arterial blood sampling in the determination of regional rates of cerebral protein synthesis with L-[1-11C]leucine PET: A validation study.

Authors:  Giampaolo Tomasi; Mattia Veronese; Alessandra Bertoldo; Carolyn B Smith; Kathleen C Schmidt
Journal:  J Cereb Blood Flow Metab       Date:  2018-04-17       Impact factor: 6.200

6.  Quantification of [18F]UCB-H Binding in the Rat Brain: From Kinetic Modelling to Standardised Uptake Value.

Authors:  Maria Elisa Serrano; Mohamed Ali Bahri; Guillaume Becker; Alain Seret; Frédéric Mievis; Fabrice Giacomelli; Christian Lemaire; Eric Salmon; André Luxen; Alain Plenevaux
Journal:  Mol Imaging Biol       Date:  2019-10       Impact factor: 3.488

7.  Automated reference region extraction and population-based input function for brain [(11)C]TMSX PET image analyses.

Authors:  Eero Rissanen; Jouni Tuisku; Pauliina Luoto; Eveliina Arponen; Jarkko Johansson; Vesa Oikonen; Riitta Parkkola; Laura Airas; Juha O Rinne
Journal:  J Cereb Blood Flow Metab       Date:  2014-11-05       Impact factor: 6.200

8.  Image-derived input function with factor analysis and a-priori information.

Authors:  Urban Simončič; Paolo Zanotti-Fregonara
Journal:  Nucl Med Commun       Date:  2015-02       Impact factor: 1.690

9.  Comparison of Invasive and Non-invasive Estimation of [11C]PBR28 Binding in Non-human Primates.

Authors:  Lucero Aceves-Serrano; Vesna Sossi; Doris J Doudet
Journal:  Mol Imaging Biol       Date:  2021-10-07       Impact factor: 3.488

10.  Retest imaging of [11C]NOP-1A binding to nociceptin/orphanin FQ peptide (NOP) receptors in the brain of healthy humans.

Authors:  Talakad G Lohith; Sami S Zoghbi; Cheryl L Morse; Maria D Ferraris Araneta; Vanessa N Barth; Nancy A Goebl; Johannes T Tauscher; Victor W Pike; Robert B Innis; Masahiro Fujita
Journal:  Neuroimage       Date:  2013-11-10       Impact factor: 6.556

View more