Literature DB >> 15586629

Evaluation of the use of a standard input function for compartment analysis of [123I]iomazenil data: factors influencing the quantitative results.

Yujiro Seike1, Kazuo Hashikawa, Naohiko Oku, Hiroshi Moriwaki, Haruko Yamamoto, Kazuki Fukuchi, Yoshiyuki Watanabe, Masayasu Matsumoto, Masatsugu Hori, Tsunehiko Nishimura.   

Abstract

Adoption of standard input function (SIF) has been proposed for kinetic analysis of receptor binding potential (BP), instead of invasive frequent arterial samplings. The purpose of this study was to assess the SIF method in quantitative analysis of [123I]iomazenil (IMZ), a central benzodiazepine antagonist, for SPECT. SPECT studies were performed on 10 patients with cerebrovascular disease or Alzheimer disease. Intermittent dynamic SPECT scans were performed from 0 to 201 min after IMZ-injection. BPs calculated from SIFs obtained from normal volunteers (BPs) were compared with those of individual arterial samplings (BPo). Good correlations were shown between BP(o)s and BP(s)s in the 9 subjects, but maximum BP(s)s were four times larger than the corresponding BP(o)s in one case. There were no abnormal laboratory data in this patient, but the relative arterial input count in the late period was higher than the SIF. Simulation studies with modified input functions revealed that height in the late period can produce significant errors in estimated BPs. These results suggested that the simplified method with one-point arterial sampling and SIF can not be applied clinically. One additional arterial sampling in the late period may be useful.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15586629     DOI: 10.1007/bf02984577

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  5 in total

1.  Minimally invasive input function for 2-18F-fluoro-A-85380 brain PET studies.

Authors:  Paolo Zanotti-Fregonara; Renaud Maroy; Marie-Anne Peyronneau; Régine Trebossen; Michel Bottlaender
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-01-10       Impact factor: 9.236

Review 2.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

3.  Population-based input function and image-derived input function for [¹¹C](R)-rolipram PET imaging: methodology, validation and application to the study of major depressive disorder.

Authors:  Paolo Zanotti-Fregonara; Christina S Hines; Sami S Zoghbi; Jeih-San Liow; Yi Zhang; Victor W Pike; Wayne C Drevets; Alan G Mallinger; Carlos A Zarate; Masahiro Fujita; Robert B Innis
Journal:  Neuroimage       Date:  2012-08-10       Impact factor: 6.556

4.  Standardized Input Function for 18F-FDG PET Studies in Mice: A Cautionary Study.

Authors:  Marie Meyer; Lucie Le-Bras; Philippe Fernandez; Paolo Zanotti-Fregonara
Journal:  PLoS One       Date:  2017-01-26       Impact factor: 3.240

5.  Population-based input function modeling for [(18)F]FMPEP-d 2, an inverse agonist radioligand for cannabinoid CB1 receptors: validation in clinical studies.

Authors:  Paolo Zanotti-Fregonara; Jussi Hirvonen; Chul Hyoung Lyoo; Sami S Zoghbi; Denise Rallis-Frutos; Marilyn A Huestis; Cheryl Morse; Victor W Pike; Robert B Innis
Journal:  PLoS One       Date:  2013-04-05       Impact factor: 3.240

  5 in total