Literature DB >> 22906688

Determination of trace human chorionic gonadotropin by using multiwall carbon nanotubes as phosphorescence labeling reagent.

Jia-Ming Liu1, Xiao-Mei Huang, Ma-Lin Cui, Li-Ping Lin, Li-Hong Zhang, Zhi-Yong Zheng, Shao-Qin Lin.   

Abstract

Taking advantage of the cutting effect of the strong oxidation of benzoyl peroxide [(C(6)H(5)CO)(2)O(2)] on the end of multiwall carbon nanotubes (MWNTs) to obtain water-soluble multiwall nanotubes (MWNTs') and the spiking effect of polyacrylamide (PA) on the room temperature phosphorescence (RTP) of MWNTs', a new phosphorescent labeling reagent, MWNTs'-PA, has been developed in this study. The product β-Ab(HCG)-MWNTs'-PA obtained by MWNTs'-PA labeling human chorionic gonadotropin-β-subunit three-dimensional core monoclonal antibody (β-Ab(HCG)) not only could maintain good RTP characteristics of MWNTs' but also could take specific immunoreaction with β-HCG to form β-HCG- β-Ab(HCG)-MWNTs'-PA, resulting in the increase of MWNTs' RTP signal. Thus, a new solid substrate room temperature phosphorescence immunoassay (SSRTPIA) for the determination of β-HCG has been established. The limits of detection (LODs) of the new method were 0.021pgspot(-1) for the direct way at 447/615nm (λ(ex)(max)/λ(em)(max)) and 0.016pgspot(-1) for the sandwich way at 447/614nm (λ(ex)(max)/λ(em)(max)). This sensitive, accurate, and precise method was used to determine β-HCG and diagnose human diseases by the direct way or the sandwich way, with the results coinciding with those obtained by chemiluminescence immunoassay. Meanwhile, the mechanisms of MWNTs' labeling β-Ab(HCG) and determining β-HCG are also discussed.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22906688     DOI: 10.1016/j.ab.2012.08.007

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  2 in total

Review 1.  Carbon nanotubes in electrochemical, colorimetric, and fluorimetric immunosensors and immunoassays: a review.

Authors:  Hualin Yang; Wentao Xu; Xiongyan Liang; Yuying Yang; Yu Zhou
Journal:  Mikrochim Acta       Date:  2020-03-09       Impact factor: 5.833

2.  A Point-of-Care Immunosensor for Human Chorionic Gonadotropin in Clinical Urine Samples Using a Cuneated Polysilicon Nanogap Lab-on-Chip.

Authors:  S R Balakrishnan; U Hashim; Subash C B Gopinath; P Poopalan; H R Ramayya; M Iqbal Omar; R Haarindraprasad; P Veeradasan
Journal:  PLoS One       Date:  2015-09-14       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.