Literature DB >> 22902864

QRS detection based ECG quality assessment.

Dieter Hayn1, Bernhard Jammerbund, Günter Schreier.   

Abstract

Although immediate feedback concerning ECG signal quality during recording is useful, up to now not much literature describing quality measures is available. We have implemented and evaluated four ECG quality measures. Empty lead criterion (A), spike detection criterion (B) and lead crossing point criterion (C) were calculated from basic signal properties. Measure D quantified the robustness of QRS detection when applied to the signal. An advanced Matlab-based algorithm combining all four measures and a simplified algorithm for Android platforms, excluding measure D, were developed. Both algorithms were evaluated by taking part in the Computing in Cardiology Challenge 2011. Each measure's accuracy and computing time was evaluated separately. During the challenge, the advanced algorithm correctly classified 93.3% of the ECGs in the training-set and 91.6 % in the test-set. Scores for the simplified algorithm were 0.834 in event 2 and 0.873 in event 3. Computing time for measure D was almost five times higher than for other measures. Required accuracy levels depend on the application and are related to computing time. While our simplified algorithm may be accurate for real-time feedback during ECG self-recordings, QRS detection based measures can further increase the performance if sufficient computing power is available.

Mesh:

Year:  2012        PMID: 22902864     DOI: 10.1088/0967-3334/33/9/1449

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  14 in total

Review 1.  A review of methods for the signal quality assessment to improve reliability of heart rate and blood pressures derived parameters.

Authors:  Nicolò Gambarotta; Federico Aletti; Giuseppe Baselli; Manuela Ferrario
Journal:  Med Biol Eng Comput       Date:  2016-02-23       Impact factor: 2.602

2.  Arrhythmia Detection in Pediatric Patients: ECG Quality and Diagnostic Yield of a Patient-Triggered Einthoven Lead-I Event Recorder (Zenicor EKG-2™).

Authors:  Lea Usadel; Guido Haverkämper; Susanne Herrmann; Rebekka Löber; Katja Weiss; Bernd Opgen-Rhein; Felix Berger; Joachim C Will
Journal:  Pediatr Cardiol       Date:  2015-11-14       Impact factor: 1.655

3.  Assessing ECG signal quality indices to discriminate ECGs with artefacts from pathologically different arrhythmic ECGs.

Authors:  C Daluwatte; L Johannesen; L Galeotti; J Vicente; D G Strauss; C G Scully
Journal:  Physiol Meas       Date:  2016-07-25       Impact factor: 2.833

4.  Quality estimation of the electrocardiogram using cross-correlation among leads.

Authors:  Eduardo Morgado; Felipe Alonso-Atienza; Ricardo Santiago-Mozos; Óscar Barquero-Pérez; Ikaro Silva; Javier Ramos; Roger Mark
Journal:  Biomed Eng Online       Date:  2015-06-20       Impact factor: 2.819

5.  False alarm reduction in BSN-based cardiac monitoring using signal quality and activity type information.

Authors:  Tanatorn Tanantong; Ekawit Nantajeewarawat; Surapa Thiemjarus
Journal:  Sensors (Basel)       Date:  2015-02-09       Impact factor: 3.576

6.  Using Lempel-Ziv Complexity to Assess ECG Signal Quality.

Authors:  Yatao Zhang; Shoushui Wei; Costanzo Di Maria; Chengyu Liu
Journal:  J Med Biol Eng       Date:  2016-10-05       Impact factor: 1.553

7.  Noise Maps for Quantitative and Clinical Severity Towards Long-Term ECG Monitoring.

Authors:  Estrella Everss-Villalba; Francisco Manuel Melgarejo-Meseguer; Manuel Blanco-Velasco; Francisco Javier Gimeno-Blanes; Salvador Sala-Pla; José Luis Rojo-Álvarez; Arcadi García-Alberola
Journal:  Sensors (Basel)       Date:  2017-10-25       Impact factor: 3.576

8.  Evaluation of a Multichannel Non-Contact ECG System and Signal Quality Algorithms for Sleep Apnea Detection and Monitoring.

Authors:  Ivan D Castro; Carolina Varon; Tom Torfs; Sabine Van Huffel; Robert Puers; Chris Van Hoof
Journal:  Sensors (Basel)       Date:  2018-02-13       Impact factor: 3.576

9.  Performance Analysis of Ten Common QRS Detectors on Different ECG Application Cases.

Authors:  Feifei Liu; Chengyu Liu; Xinge Jiang; Zhimin Zhang; Yatao Zhang; Jianqing Li; Shoushui Wei
Journal:  J Healthc Eng       Date:  2018-05-08       Impact factor: 2.682

10.  SQI Quality Evaluation Mechanism of Single-Lead ECG Signal Based on Simple Heuristic Fusion and Fuzzy Comprehensive Evaluation.

Authors:  Zhidong Zhao; Yefei Zhang
Journal:  Front Physiol       Date:  2018-06-14       Impact factor: 4.566

View more