Literature DB >> 22899104

Motion corrected compressed sensing for free-breathing dynamic cardiac MRI.

Muhammad Usman1, David Atkinson, Freddy Odille, Christoph Kolbitsch, Ghislain Vaillant, Tobias Schaeffter, Philip G Batchelor, Claudia Prieto.   

Abstract

Compressed sensing (CS) has been demonstrated to accelerate MRI acquisitions by reconstructing sparse images of good quality from highly undersampled data. Motion during MR scans can cause inconsistencies in k-space data, resulting in strong motion artifacts in the reconstructed images. For CS to be useful in these applications, motion correction techniques need to be combined with the undersampled reconstruction. Recently, joint motion correction and CS approaches have been proposed to partially correct for effects of motion. However, the main limitation of these approaches is that they can only correct for affine deformations. In this work, we propose a novel motion corrected CS framework for free-breathing dynamic cardiac MRI that incorporates a general motion correction formulation directly into the CS reconstruction. This framework can correct for arbitrary affine or nonrigid motion in the CS reconstructed cardiac images, while simultaneously benefiting from highly accelerated MR acquisition. The application of this approach is demonstrated both in simulations and in vivo data for 2D respiratory self-gated free-breathing cardiac CINE MRI, using a golden angle radial acquisition. Results show that this approach allows for the reconstruction of respiratory motion corrected cardiac CINE images with similar quality to breath-held acquisitions.
© 2012 Wiley Periodicals, Inc.

Entities:  

Keywords:  compressed sensing; dynamic cardiac MRI; motion correction; nonrigid motion; undersampling

Mesh:

Year:  2012        PMID: 22899104     DOI: 10.1002/mrm.24463

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  50 in total

1.  Motion correction of multi-contrast images applied to T₁and T₂quantification in cardiac MRI.

Authors:  Anne Menini; Glenn S Slavin; Jeffrey A Stainsby; Pauline Ferry; Jacques Felblinger; Freddy Odille
Journal:  MAGMA       Date:  2015-02       Impact factor: 2.310

2.  Algebraic reconstruction technique for parallel imaging reconstruction of undersampled radial data: application to cardiac cine.

Authors:  Shu Li; Cheong Chan; Jason P Stockmann; Hemant Tagare; Ganesh Adluru; Leo K Tam; Gigi Galiana; R Todd Constable; Sebastian Kozerke; Dana C Peters
Journal:  Magn Reson Med       Date:  2014-04-18       Impact factor: 4.668

Review 3.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

4.  High spatial and temporal resolution dynamic contrast-enhanced magnetic resonance angiography using compressed sensing with magnitude image subtraction.

Authors:  Stanislas Rapacchi; Fei Han; Yutaka Natsuaki; Randall Kroeker; Adam Plotnik; Evan Lehrman; James Sayre; Gerhard Laub; J Paul Finn; Peng Hu
Journal:  Magn Reson Med       Date:  2013-06-25       Impact factor: 4.668

5.  Functional imaging of murine hearts using accelerated self-gated UTE cine MRI.

Authors:  Abdallah G Motaal; Nils Noorman; Wolter L de Graaf; Verena Hoerr; Luc M J Florack; Klaas Nicolay; Gustav J Strijkers
Journal:  Int J Cardiovasc Imaging       Date:  2014-09-10       Impact factor: 2.357

Review 6.  Compressed sensing for body MRI.

Authors:  Li Feng; Thomas Benkert; Kai Tobias Block; Daniel K Sodickson; Ricardo Otazo; Hersh Chandarana
Journal:  J Magn Reson Imaging       Date:  2016-12-16       Impact factor: 4.813

Review 7.  Cardiac Magnetic Resonance Quantification of Structure-Function Relationships in Heart Failure.

Authors:  Kim-Lien Nguyen; Peng Hu; J Paul Finn
Journal:  Heart Fail Clin       Date:  2020-10-28       Impact factor: 3.179

8.  Motion-compensated data decomposition algorithm to accelerate dynamic cardiac MRI.

Authors:  Azar Tolouee; Javad Alirezaie; Paul Babyn
Journal:  MAGMA       Date:  2017-05-31       Impact factor: 2.310

9.  Deformation corrected compressed sensing (DC-CS): a novel framework for accelerated dynamic MRI.

Authors:  Sajan Goud Lingala; Edward DiBella; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2014-07-29       Impact factor: 10.048

10.  High efficiency coronary MR angiography with nonrigid cardiac motion correction.

Authors:  Jianing Pang; Yuhua Chen; Zhaoyang Fan; Christopher Nguyen; Qi Yang; Yibin Xie; Debiao Li
Journal:  Magn Reson Med       Date:  2016-07-25       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.