Literature DB >> 22898660

Label-free impedimetric immunosensor for ultrasensitive detection of cancer marker Murine double minute 2 in brain tissue.

Reda Elshafey1, Chaker Tlili, Abedelnasser Abulrob, Ana C Tavares, Mohammed Zourob.   

Abstract

The detection of cancer biomarkers is as important tool for the diagnosis and prognosis of cancer such as brain cancer. Murine double minute 2 (MDM2) has been widely studied as prognostic marker for brain tumor. Here we describe development of a new sensitive label free impedimetric immunosensor for the detection of MDM2 based on cysteamine self assembled monolayers on a clean polycrystalline Au electrode surface. The amine-modified electrodes were further functionalized with antibody using homobifunctional 1,4-phenylene diisothiocyanate (PDITC) linker. The assembly processes of the immunosensor had been monitored with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques using Fe(CN)(6)(3-/4-) solution as redox probe. The impedance changes upon binding of MDM2 protein to the sensor surface was utilized for the detection of MDM2. The increase in relative electron-transfer resistance (ΔR/R(0)%) values was linearly proportional to the concentration of tumor marker MDM2 in the wide dynamic range of 1pg/ml-1μg/ml. The limit of detection was 0.29pg/ml in phosphate buffer saline (PBS) and 1.3pg/ml in mouse brain tissue homogenate, respectively. The immunosensor showed a good performance in comparison with ELISA for the analysis of the MDM2 in the cancerous mouse brain tissue homogenates. Moreover, the immunosensor had a good selectivity against epidermal growth factor receptor (EGFR) protein, long-storage stability and reproducibility. It might be become a promising assay for clinical diagnosis and early detection of tumors.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22898660     DOI: 10.1016/j.bios.2012.07.049

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Point-of-care diagnostics for infectious diseases: From methods to devices.

Authors:  Chao Wang; Mei Liu; Zhifei Wang; Song Li; Yan Deng; Nongyue He
Journal:  Nano Today       Date:  2021-02-06       Impact factor: 20.722

2.  High-density CMOS Microelectrode Array System for Impedance Spectroscopy and Imaging of Biological Cells.

Authors:  Viswam Vijay; Bounik Raziyeh; Shadmani Amir; Dragas Jelena; Boos Julia Alicia; Birchler Axel; Müller Jan; Chen Yihui; Hierlemann Andreas
Journal:  Proc IEEE Sens       Date:  2017-01-26

3.  Impedance Spectroscopy and Electrophysiological Imaging of Cells With a High-Density CMOS Microelectrode Array System.

Authors:  Vijay Viswam; Raziyeh Bounik; Amir Shadmani; Jelena Dragas; Cedar Urwyler; Julia Alicia Boos; Marie Engelene J Obien; Jan Muller; Yihui Chen; Andreas Hierlemann
Journal:  IEEE Trans Biomed Circuits Syst       Date:  2018-11-12       Impact factor: 3.833

Review 4.  Electrochemical Biosensors for Detection of MicroRNA as a Cancer Biomarker: Pros and Cons.

Authors:  Maliana El Aamri; Ghita Yammouri; Hasna Mohammadi; Aziz Amine; Hafsa Korri-Youssoufi
Journal:  Biosensors (Basel)       Date:  2020-11-20

5.  A Multi-Functional Microelectrode Array Featuring 59760 Electrodes, 2048 Electrophysiology Channels, Stimulation, Impedance Measurement and Neurotransmitter Detection Channels.

Authors:  Jelena Dragas; Vijay Viswam; Amir Shadmani; Yihui Chen; Raziyeh Bounik; Alexander Stettler; Milos Radivojevic; Sydney Geissler; Marie Obien; Jan Müller; Andreas Hierlemann
Journal:  IEEE J Solid-State Circuits       Date:  2017-04-27       Impact factor: 5.013

Review 6.  A review on impedimetric immunosensors for pathogen and biomarker detection.

Authors:  J Leva-Bueno; Sally A Peyman; P A Millner
Journal:  Med Microbiol Immunol       Date:  2020-04-03       Impact factor: 3.402

  6 in total