Literature DB >> 22897326

Standardization of assay methods reduces variability of total PSA measurements: an Irish study.

James C Forde1, Laure Marignol, Ophelia Blake, Ted McDermott, Ronald Grainger, Vivien E Crowley, Thomas H Lynch.   

Abstract

UNLABELLED: What's known on the subject? and What does the study add? Today, numerous assays for PSA detection are available from various manufacturers. However, these various assays do not detect PSA equally and several studies have demonstrated variability between them. In order to harmonise PSA results and reduce the discrepancies, reference materials are available for assay calibration. We have demonstrated significantly variability between 6 different assay methods currently in use in 9 hospitals despite assay calibration. Variability in PSA values was reduced with the standardisation of the assay method in 4 hospitals. Our results highlight the dilemma of PSA assay variability and stress the need for nationwide standardisation of PSA testing.
OBJECTIVE: To determine whether standardization of total prostate-specific antigen (tPSA) assay methods reduces variability in tPSA measurements. PATIENTS AND METHODS: Blood samples from 84 patients attending a single urology department were distributed across nine hospitals selected throughout Ireland for the independent determination of tPSA under the same conditions. The selected hospitals collectively used six different assay methods for tPSA detection: Beckman Hybritech WHO Calibrated (used as reference method), Tosoh AIA 1800, Roche E170 (used in three hospitals), Abbott AxSYM, Immulite 2500 2nd Generation (used in two hospitals) and Siemens ADVIA Centaur. The method of tPSA detection was next standardized in a subset of four hospitals using the same assay method and the measurements were repeated. The difference in mean tPSA in the cohort across the hospitals tested was determined and the Bland-Altman test was used to assess the agreement between each test. Analysis was performed over both the full (0.5-30 µg/L, N = 84) and a narrow (3-7 µg/L, n = 25) tPSA range.
RESULTS: The range and the mean tPSA of the full cohort were inflated across the eight test hospitals, when compared with the reference hospital. The poorest agreement between assay methods was associated with a bias of 2.2 ± 2.4 µg/L. The variability in tPSA measurements between assay methods was inconsistent across the range of tPSA values tested and increased with increasing mean tPSA. Agreement in reported tPSA was excellent after standardization of tPSA assay methods (bias <0.2 µg/L). Over the narrow 3-7 µg/L PSA range, 12/25 (48%) patients had a tPSA range of values across all hospitals in excess of 2 µg/L. Following standardization of the tPSA assay method, patient tPSA ranges were <0.5 µg/L for 13/25 (52%) patients.
CONCLUSIONS: We have shown that the lack of standardization of tPSA assay methods across a panel of Irish hospitals leads to significant variability in the measured tPSA values for the same patient samples. Variability in tPSA values was reduced with the standardization of the assay method in four hospitals. Standardization of PSA testing on a nationwide scale is warranted.
© 2012 BJU INTERNATIONAL.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22897326     DOI: 10.1111/j.1464-410X.2011.10923.x

Source DB:  PubMed          Journal:  BJU Int        ISSN: 1464-4096            Impact factor:   5.588


  8 in total

1.  Variability of assay methods for total and free PSA after WHO standardization.

Authors:  L Foj; X Filella; J Alcover; J M Augé; J M Escudero; R Molina
Journal:  Tumour Biol       Date:  2013-10-04

2.  The number of tPSA tests continues to rise and variation in testing practices persists: a survey of laboratory services in Ireland 2008-2010.

Authors:  F J Drummond; E Barrett; R Burns; C O'Neill; L Sharp
Journal:  Ir J Med Sci       Date:  2013-09-27       Impact factor: 1.568

3.  Predicting prostate cancer: analysing the clinical efficacy of prostate cancer risk calculators in a referral population.

Authors:  R W Foley; D J Lundon; K Murphy; T B Murphy; D J Galvin; R W G Watson
Journal:  Ir J Med Sci       Date:  2015-04-07       Impact factor: 1.568

4.  A single centre experience of active surveillance as management strategy for low-risk prostate cancer in Ireland.

Authors:  J C Forde; P J Daly; S White; M Morrin; G P Smyth; B D P O'Neill; R E Power
Journal:  Ir J Med Sci       Date:  2013-09-29       Impact factor: 1.568

5.  Comparison of Three Assays for Total and Free PSA Using Hybritech and WHO Calibrations.

Authors:  Manuel M Garrido; José C Marta; Ruy M Ribeiro; Luís C Pinheiro; Stefan Holdenrieder; João T Guimarães
Journal:  In Vivo       Date:  2021 Nov-Dec       Impact factor: 2.155

6.  Molecular Form Differences Between Prostate-Specific Antigen (PSA) Standards Create Quantitative Discordances in PSA ELISA Measurements.

Authors:  Erica L McJimpsey
Journal:  Sci Rep       Date:  2016-02-25       Impact factor: 4.379

7.  Investigating the prostate specific antigen, body mass index and age relationship: is an age-BMI-adjusted PSA model clinically useful?

Authors:  Sean Harrison; Kate Tilling; Emma L Turner; J Athene Lane; Andrew Simpkin; Michael Davis; Jenny Donovan; Freddie C Hamdy; David E Neal; Richard M Martin
Journal:  Cancer Causes Control       Date:  2016-11-09       Impact factor: 2.506

8.  A risk calculator to inform the need for a prostate biopsy: a rapid access clinic cohort.

Authors:  Amirhossein Jalali; Robert W Foley; Robert M Maweni; Keefe Murphy; Dara J Lundon; Thomas Lynch; Richard Power; Frank O'Brien; Kieran J O'Malley; David J Galvin; Garrett C Durkan; T Brendan Murphy; R William Watson
Journal:  BMC Med Inform Decis Mak       Date:  2020-07-03       Impact factor: 2.796

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.