Personalized image-based templates for iliosacral screw insertions: a pilot study.

Bin Chen1, Yuanzhi Zhang, Shengxiang Xiao, Pengcheng Gu, Xiangjin Lin.   

Abstract

BACKGROUND: Stabilization of rare unstable pelvic fractures in the case of sacral fractures and iliosacral joint dislocations can be tricky. 3D reconstruction and reverse engineering templates may be used to increase the accuracy of screw placement.
METHODS: Computed tomography (CT) images were used to design the template for 16 consecutive patients with unstable pelvic ring fractures, which were used to guide the screw placement. Another 10 patients received screw placement under conventional fluoroscopy. The screw position, radiation exposure, and surgery time were compared between the two groups.
RESULTS: Personalized image-based templates had better correct screw positions (P < 0.05), reduced radiation exposure (P < 0.01), and shorter surgery time (P < 0.05) compared with the conventional group.
CONCLUSIONS: Personalized image-based templates for iliosacral screw insertions can increase the sacral lag screw placement accuracy, reduce radiation exposure, and shorten surgery time compared with traditional fluoroscopic methods.
Copyright © 2012 John Wiley & Sons, Ltd.

Entities:  

Mesh:

Year:  2012        PMID: 22893233     DOI: 10.1002/rcs.1453

Source DB:  PubMed          Journal:  Int J Med Robot        ISSN: 1478-5951            Impact factor:   2.547


  7 in total

1.  [Precise sacroiliac joint screw insertion without computed tomography, digital volume tomography or navigation systems].

Authors:  B Roetman; I Ilchuk; B Khatib; U Goerigk; M Gothner
Journal:  Oper Orthop Traumatol       Date:  2019-06-03       Impact factor: 1.154

2.  Development of a surgical navigation system based on 3D Slicer for intraoperative implant placement surgery.

Authors:  Xiaojun Chen; Lu Xu; Huixiang Wang; Fang Wang; Qiugen Wang; Ron Kikinis
Journal:  Med Eng Phys       Date:  2017-01-18       Impact factor: 2.242

Review 3.  Pelvic trauma: WSES classification and guidelines.

Authors:  Federico Coccolini; Philip F Stahel; Giulia Montori; Walter Biffl; Tal M Horer; Fausto Catena; Yoram Kluger; Ernest E Moore; Andrew B Peitzman; Rao Ivatury; Raul Coimbra; Gustavo Pereira Fraga; Bruno Pereira; Sandro Rizoli; Andrew Kirkpatrick; Ari Leppaniemi; Roberto Manfredi; Stefano Magnone; Osvaldo Chiara; Leonardo Solaini; Marco Ceresoli; Niccolò Allievi; Catherine Arvieux; George Velmahos; Zsolt Balogh; Noel Naidoo; Dieter Weber; Fikri Abu-Zidan; Massimo Sartelli; Luca Ansaloni
Journal:  World J Emerg Surg       Date:  2017-01-18       Impact factor: 5.469

4.  A novel patient-specific three-dimensional-printed external template to guide iliosacral screw insertion: a retrospective study.

Authors:  Fan Yang; Sheng Yao; Kai-Fang Chen; Feng-Zhao Zhu; Ze-Kang Xiong; Yan-Hui Ji; Ting-Fang Sun; Xiao-Dong Guo
Journal:  BMC Musculoskelet Disord       Date:  2018-11-13       Impact factor: 2.362

5.  Minimally Invasive Screw Fixation of Unstable Pelvic Fractures Using the "Blunt End" Kirschner Wire Technique Assisted by 3D Printed External Template.

Authors:  Kaifang Chen; Sheng Yao; Fan Yang; Deepak Drepaul; Dionne Telemacque; Fengzhao Zhu; Lian Zeng; Zekang Xiong; Tingfang Sun; Xiaodong Guo
Journal:  Biomed Res Int       Date:  2019-10-24       Impact factor: 3.411

6.  3D-printed guiding templates for improved osteosarcoma resection.

Authors:  Limin Ma; Ye Zhou; Ye Zhu; Zefeng Lin; Yingjun Wang; Yu Zhang; Hong Xia; Chuanbin Mao
Journal:  Sci Rep       Date:  2016-03-21       Impact factor: 4.379

7.  A semi-automatic computer-aided method for surgical template design.

Authors:  Xiaojun Chen; Lu Xu; Yue Yang; Jan Egger
Journal:  Sci Rep       Date:  2016-02-04       Impact factor: 4.379

  7 in total