Literature DB >> 22889776

Image quality and data quantification in dopamine transporter SPECT: advantage of 3-dimensional OSEM reconstruction?

Oliver H Winz1, Sabine Hellwig, Michael Mix, Wolfgang A Weber, Felix M Mottaghy, Wolfgang M Schäfer, Philipp T Meyer.   

Abstract

PURPOSE: Reconstruction of striatal dopamine transporter (DAT) SPECT is commonly done by filtered back projection (FBP). We investigated if image reconstruction by 3-dimensional ordered-subset expectation maximization (3D-OSEM) with resolution recovery, which has recently become available for clinical routine, provides a relevant improvement.
METHODS: I-FP-CIT SPECT studies of 18 patients with normal to severely decreased DAT binding were reconstructed by FBP, 2D-OSEM (without resolution recovery), and 3D-OSEM, each with 2 different filter settings, yielding 3 data set pairs of relatively low and high resolution and noise: FBP with seventh-order Butterworth filter [cutoff frequency, 0.36 Nyquist (FBPlow) and 0.45 Nyquist (FBPhigh)] and OSEM with 8 iterations and 8 subsets (2D-/3D-OSEMlow) and 6 iterations and 16 subsets (2D-/3D-OSEMhigh), each with 8-mm Gaussian filtering. Mean regional counts, variability of counts (coefficient of variation), and binding potential (BPND) were assessed by volume-of-interest analyses of the caudate nucleus, the putamen, and the occipital cortex (reference region).
RESULTS: On visual inspection, both 2D- and 3D-OSEM-reconstructed images showed an optimal delineation of striatal structures, whereas variability (noise) of nonspecific cortical I-FP-CIT uptake was lowest (most homogenous) with FBPlow, slightly higher with 2D-/3D-OSEMlow, and notably higher for the other methods. Volume-of-interest analyses revealed no significant differences of counts in the occipital reference region in comparison to FBPlow (reference method). In caudate nucleus, counts and, consequently, BPND values increased significantly with FBPhigh (mean BPND change, +5.2%), 2D-OSEMlow/high (+3.7%/+6.2%), and, most notably, 3D-OSEMlow/high (+11.1%/+14.0%). In the putamen, this effect was less pronounced for FBPhigh (+1.8%) and 3D-OSEMlow/high (+5.6%/+6.8%) and failed to reach statistical significance for 2D-OSEMlow/high (-0.2%/+0.8%). Regression analyses indicated excellent correlations of BPND between FBPlow and all other methods (R > 0.97), with the highest regression slopes for 3D-OSEM (1.12-1.16) followed by FBPhigh (1.04-1.06) and then 2D-OSEM (1.01-1.04). The order of the variability of counts in the occipital cortex was as follows: FBPlow (12.5%), 2D-OSEMlow (13.9%), 3D-OSEMlow (14.2%), FBPhigh (15.1%), 2D-OSEMhigh (17.0%), and 3D-OSEMhigh (17.6%).
CONCLUSIONS: Three-dimensional OSEM considerably improves DAT SPECT reconstruction by offering an optimal combination of high-resolution delineation of striatal structures, superior recovery of signal and BPND, and sufficiently homogeneous nonspecific tracer uptake of the reference region.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22889776     DOI: 10.1097/RLU.0b013e318251e1b3

Source DB:  PubMed          Journal:  Clin Nucl Med        ISSN: 0363-9762            Impact factor:   7.794


  10 in total

1.  Influence of CT-based attenuation correction on dopamine transporter SPECT with [(123)I]FP-CIT.

Authors:  Constantin Lapa; Timo S Spehl; Joachim Brumberg; Ioannis U Isaias; Susanne Schlögl; Michael Lassmann; Ken Herrmann; Philipp T Meyer
Journal:  Am J Nucl Med Mol Imaging       Date:  2015-02-15

2.  Robust, fully automatic delineation of the head contour by stereotactical normalization for attenuation correction according to Chang in dopamine transporter scintigraphy.

Authors:  Catharina Lange; Jens Kurth; Anita Seese; Sarah Schwarzenböck; Karen Steinhoff; Bert Umland-Seidler; Bernd J Krause; Winfried Brenner; Osama Sabri; Swen Hesse; Ralph Buchert
Journal:  Eur Radiol       Date:  2015-02-26       Impact factor: 5.315

3.  Antidepressant treatment effects on dopamine transporter availability in patients with major depression: a prospective 123I-FP-CIT SPECT imaging genetic study.

Authors:  Sabine Hellwig; Lars Frings; Annette Masuch; Werner Vach; Katharina Domschke; Claus Normann; Philipp T Meyer
Journal:  J Neural Transm (Vienna)       Date:  2018-02-23       Impact factor: 3.575

4.  Impact of age and sex correction on the diagnostic performance of dopamine transporter SPECT.

Authors:  Helen Schmitz-Steinkrüger; Catharina Lange; Ivayla Apostolova; Franziska L Mathies; Lars Frings; Susanne Klutmann; Sabine Hellwig; Philipp T Meyer; Ralph Buchert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-10-31       Impact factor: 9.236

5.  CT-based attenuation correction in I-123-ioflupane SPECT.

Authors:  Catharina Lange; Anita Seese; Sarah Schwarzenböck; Karen Steinhoff; Bert Umland-Seidler; Bernd J Krause; Winfried Brenner; Osama Sabri; Jens Kurth; Swen Hesse; Ralph Buchert
Journal:  PLoS One       Date:  2014-09-30       Impact factor: 3.240

6.  Evaluation of Iterative Reconstruction Method and Attenuation Correction in Brain Dopamine Transporter SPECT Using an Anthropomorphic Striatal Phantom.

Authors:  Akira Maebatake; Ayaka Imamura; Yui Kodera; Yasuo Yamashita; Kazuhiko Himuro; Shingo Baba; Kenta Miwa; Masayuki Sasaki
Journal:  Asia Ocean J Nucl Med Biol       Date:  2016

7.  Imaging analysis of Parkinson's disease patients using SPECT and tractography.

Authors:  Seong-Jin Son; Mansu Kim; Hyunjin Park
Journal:  Sci Rep       Date:  2016-11-30       Impact factor: 4.379

8.  Dermal phospho-alpha-synuclein deposits confirm REM sleep behaviour disorder as prodromal Parkinson's disease.

Authors:  Kathrin Doppler; Hanna-Maria Jentschke; Lena Schulmeyer; David Vadasz; Annette Janzen; Markus Luster; Helmut Höffken; Geert Mayer; Joachim Brumberg; Jan Booij; Thomas Musacchio; Stephan Klebe; Elisabeth Sittig-Wiegand; Jens Volkmann; Claudia Sommer; Wolfgang H Oertel
Journal:  Acta Neuropathol       Date:  2017-02-08       Impact factor: 17.088

9.  Diagnostic performance of the specific uptake size index for semi-quantitative analysis of I-123-FP-CIT SPECT: harmonized multi-center research setting versus typical clinical single-camera setting.

Authors:  Ralph Buchert; Catharina Lange; Timo S Spehl; Ivayla Apostolova; Lars Frings; Cathrine Jonsson; Philipp T Meyer; Sabine Hellwig
Journal:  EJNMMI Res       Date:  2019-05-07       Impact factor: 3.138

10.  Multiple-pinhole collimators improve intra- and between-rater agreement and the certainty of the visual interpretation in dopamine transporter SPECT.

Authors:  Franziska Mathies; Ivayla Apostolova; Lena Dierck; Janin Jacobi; Katja Kuen; Markus Sauer; Michael Schenk; Susanne Klutmann; Attila Forgács; Ralph Buchert
Journal:  EJNMMI Res       Date:  2022-08-17       Impact factor: 3.434

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.