OBJECTIVES: Chang's method, the most widely used attenuation correction (AC) in brain single-photon emission computed tomography (SPECT), requires delineation of the outer contour of the head. Manual and automatic threshold-based methods are prone to errors due to variability of tracer uptake in the scalp. The present study proposes a new method for fully automated delineation of the head based on stereotactical normalization. The method was validated for SPECT with I-123-ioflupane.
METHODS: The new method was compared to threshold-based delineation in 62 unselected patients who had received I-123-ioflupane SPECT at one of 3 centres. The impact on diagnostic power was tested for semi-quantitative analysis and visual reading of the SPECT images (six independent readers).
RESULTS: The two delineation methods produced highly consistent semi-quantitative results. This was confirmed by receiver operating characteristic analyses in which the putamen specific-to-background ratio achieved highest area under the curve with negligible effect of the delineation method: 0.935 versus 0.938 for stereotactical normalization and threshold-based delineation, respectively. Visual interpretation of DVR images was also not affected by the delineation method.
CONCLUSIONS: Delineation of the head contour by stereotactical normalization appears useful for Chang AC in I-123-ioflupane SPECT. It is robust and does not require user interaction. KEY POINTS: •Chang attenuation correction in brain SPECT requires delineation of the head contour. •Manual and threshold-based methods are prone to errors. •The study proposes a fully-automated method for delineation based on stereotactical normalization. •The method is shown to work reliably in I-123-ioflupane SPECT. •It might improve the workflow of I-123-ioflupane SPECT in everyday patient care.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25716941     DOI: 10.1007/s00330-015-3667-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  36 in total

1.  Quantitative accuracy of dopaminergic neurotransmission imaging with (123)I SPECT.

Authors:  Marine Soret; Pierre Malick Koulibaly; Jacques Darcourt; Sébastien Hapdey; Irène Buvat
Journal:  J Nucl Med       Date:  2003-07       Impact factor: 10.057

2.  Loss of dopamine transporter binding in Parkinson's disease follows a single exponential rather than linear decline.

Authors:  Johannes Schwarz; Alexander Storch; Walter Koch; Oliver Pogarell; Perry E Radau; Klaus Tatsch
Journal:  J Nucl Med       Date:  2004-10       Impact factor: 10.057

Review 3.  Consensus nomenclature for in vivo imaging of reversibly binding radioligands.

Authors:  Robert B Innis; Vincent J Cunningham; Jacques Delforge; Masahiro Fujita; Albert Gjedde; Roger N Gunn; James Holden; Sylvain Houle; Sung-Cheng Huang; Masanori Ichise; Hidehiro Iida; Hiroshi Ito; Yuichi Kimura; Robert A Koeppe; Gitte M Knudsen; Juhani Knuuti; Adriaan A Lammertsma; Marc Laruelle; Jean Logan; Ralph Paul Maguire; Mark A Mintun; Evan D Morris; Ramin Parsey; Julie C Price; Mark Slifstein; Vesna Sossi; Tetsuya Suhara; John R Votaw; Dean F Wong; Richard E Carson
Journal:  J Cereb Blood Flow Metab       Date:  2007-05-09       Impact factor: 6.200

4.  A JAVA environment for medical image data analysis: initial application for brain PET quantitation.

Authors:  K Mikolajczyk; M Szabatin; P Rudnicki; M Grodzki; C Burger
Journal:  Med Inform (Lond)       Date:  1998 Jul-Sep

5.  Compton scatter compensation using the triple-energy window method for single- and dual-isotope SPECT.

Authors:  T Ichihara; K Ogawa; N Motomura; A Kubo; S Hashimoto
Journal:  J Nucl Med       Date:  1993-12       Impact factor: 10.057

6.  Gamma camera emission tomography. Development and properties of a multi-sectional emission computed tomography system.

Authors:  S A Larsson
Journal:  Acta Radiol Suppl       Date:  1980

7.  IBZM tool: a fully automated expert system for the evaluation of IBZM SPECT studies.

Authors:  Ralph Buchert; Georg Berding; Florian Wilke; Brigitte Martin; Daniel von Borczyskowski; Janos Mester; Winfried Brenner; Malte Clausen
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-14       Impact factor: 9.236

Review 8.  Role of DAT-SPECT in the diagnostic work up of parkinsonism.

Authors:  Christoph Scherfler; Johannes Schwarz; Angelo Antonini; Donald Grosset; Francesc Valldeoriola; Kenneth Marek; Wolfgang Oertel; Eduardo Tolosa; Andrew J Lees; Werner Poewe
Journal:  Mov Disord       Date:  2007-07-15       Impact factor: 10.338

9.  Single photon emission computed tomographic imaging demonstrates loss of striatal dopamine transporters in Parkinson disease.

Authors:  R B Innis; J P Seibyl; B E Scanley; M Laruelle; A Abi-Dargham; E Wallace; R M Baldwin; Y Zea-Ponce; S Zoghbi; S Wang
Journal:  Proc Natl Acad Sci U S A       Date:  1993-12-15       Impact factor: 11.205

10.  Optimized, automated striatal uptake analysis applied to SPECT brain scans of Parkinson's disease patients.

Authors:  I George Zubal; Michele Early; Olive Yuan; Danna Jennings; Kenneth Marek; John P Seibyl
Journal:  J Nucl Med       Date:  2007-05-15       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.