Literature DB >> 2288780

[Analysis of water content in rat brain using Raman spectroscopy].

K Tashibu1.   

Abstract

Laser Raman spectroscopy has not been applied to brain tissue. However, this method can possibly analyze the constituent elements of living tissue of cellular and molecular level easily, and this might be essential for further brain research. I attempted to analyze the water content of brain tissues, which was measured by Raman spectrum of CH and OH groups, in normal and edematous rat brain tissues. The experimental results indicated that the peak intensity of CH group originated from protein, 2935 cm-1 in wave number, was constant in normal, dried and edematous brain tissue. Therefore it could be used as internal standard. As the peak intensity of OH group, 3390 cm-1 in wave number, was originated from water, the relative amount of water content in the brain tissues could be evaluated by OH/CH value. The OH/CH value was not significantly different between the cortex and the thalamus, but it was significantly higher in the gray matter (thalamus) than in the white matter (pons). The OH/CH value was decreased in dried specimens. In experimental edematous brain tissues, which was produced by intraperitoneal injection of organic tin, the OH/CH value was evidently increased in the thalamus but not much changed in the pons. This results were well compatible with cytotoxic edema, which was reported to be produced by organic tin. It is suggested that laser Raman spectroscopy can be used for brain edema research as one of the strong weapon, in analyzing water content of brain tissues on a cellular level.

Entities:  

Mesh:

Year:  1990        PMID: 2288780

Source DB:  PubMed          Journal:  No To Shinkei        ISSN: 0006-8969


  5 in total

Review 1.  Improving the accuracy of brain tumor surgery via Raman-based technology.

Authors:  Todd Hollon; Spencer Lewis; Christian W Freudiger; X Sunney Xie; Daniel A Orringer
Journal:  Neurosurg Focus       Date:  2016-03       Impact factor: 4.047

2.  AI-Assisted In Situ Detection of Human Glioma Infiltration Using a Novel Computational Method for Optical Coherence Tomography.

Authors:  Ronald M Juarez-Chambi; Carmen Kut; Jose J Rico-Jimenez; Kaisorn L Chaichana; Jiefeng Xi; Daniel U Campos-Delgado; Fausto J Rodriguez; Alfredo Quinones-Hinojosa; Xingde Li; Javier A Jo
Journal:  Clin Cancer Res       Date:  2019-07-17       Impact factor: 12.531

Review 3.  Shining light on neurosurgery diagnostics using Raman spectroscopy.

Authors:  Brandy Broadbent; James Tseng; Rachel Kast; Thomas Noh; Michelle Brusatori; Steven N Kalkanis; Gregory W Auner
Journal:  J Neurooncol       Date:  2016-08-13       Impact factor: 4.506

Review 4.  Label-free brain tumor imaging using Raman-based methods.

Authors:  Todd Hollon; Daniel A Orringer
Journal:  J Neurooncol       Date:  2021-02-21       Impact factor: 4.506

Review 5.  Raman Spectroscopy as a Neuromonitoring Tool in Traumatic Brain Injury: A Systematic Review and Clinical Perspectives.

Authors:  Andrew R Stevens; Clarissa A Stickland; Georgia Harris; Zubair Ahmed; Pola Goldberg Oppenheimer; Antonio Belli; David J Davies
Journal:  Cells       Date:  2022-04-05       Impact factor: 6.600

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.