Literature DB >> 22881075

"Flow valve" microfluidic devices for simple, detectorless, and label-free analyte quantitation.

Debolina Chatterjee1, Danielle S Mansfield, Neil G Anderson, Sudeep Subedi, Adam T Woolley.   

Abstract

Simplified analysis systems that offer the performance of benchtop instruments but the convenience of portability are highly desirable. We have developed novel, miniature devices that feature visual inspection readout of a target's concentration from a ~1 μL volume of solution introduced into a microfluidic channel. Microchannels are constructed within an elastomeric material, and channel surfaces are coated with receptors to the target. When a solution is flowed into the channel, the target cross-links multiple receptors on the surface, resulting in constriction of the first few millimeters of the channel and stopping of flow. Quantitation is performed by measuring the distance traveled by the target solution in the channel before flow stops. A key advantage of our approach is that quantitation is accomplished by simple visual inspection of the channel, without the need for complex detection instrumentation. We have tested these devices using the model system of biotin as a receptor and streptavidin as the target. We have also characterized three factors that influence flow distance: solution viscosity, device thickness, and channel height. We found that solution capillary flow distance scales with the negative logarithm of target concentration and have detected streptavidin concentrations as low as 1 ng/mL. Finally, we have identified and evaluated a plausible mechanism wherein time-dependent channel constriction in the first few millimeters leads to concentration-dependent flow distances. Their simplicity coupled with performance makes these "flow valve" systems especially attractive for a host of analysis applications.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22881075      PMCID: PMC3426352          DOI: 10.1021/ac301278s

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  26 in total

Review 1.  Infrared spectroscopy.

Authors:  J K Gillie; J Hochlowski; G A Arbuckle-Keil
Journal:  Anal Chem       Date:  2000-06-15       Impact factor: 6.986

2.  Discrimination of DNA hybridization using chemical force microscopy.

Authors:  L T Mazzola; C W Frank; S P Fodor; C Mosher; R Lartius; E Henderson
Journal:  Biophys J       Date:  1999-06       Impact factor: 4.033

3.  Three-dimensional paper microfluidic devices assembled using the principles of origami.

Authors:  Hong Liu; Richard M Crooks
Journal:  J Am Chem Soc       Date:  2011-10-17       Impact factor: 15.419

4.  A low-cost, simple, and rapid fabrication method for paper-based microfluidics using wax screen-printing.

Authors:  Wijitar Dungchai; Orawon Chailapakul; Charles S Henry
Journal:  Analyst       Date:  2010-09-27       Impact factor: 4.616

5.  Comparison of accuracy and certainty of results of six home pregnancy tests available over-the-counter.

Authors:  Catherine Tomlinson; Jayne Marshall; Jayne E Ellis
Journal:  Curr Med Res Opin       Date:  2008-05-02       Impact factor: 2.580

6.  Macromolecular scaffolds for immobilizing small molecule microarrays in label-free detection of protein-ligand interactions on solid support.

Authors:  Y S Sun; J P Landry; Y Y Fei; X D Zhu; J T Luo; X B Wang; K S Lam
Journal:  Anal Chem       Date:  2009-07-01       Impact factor: 6.986

7.  Covalently functionalized nanotubes as nanometre-sized probes in chemistry and biology.

Authors:  S S Wong; E Joselevich; A T Woolley; C L Cheung; C M Lieber
Journal:  Nature       Date:  1998-07-02       Impact factor: 49.962

8.  Applications and recent developments of multi-analyte simultaneous analysis by enzyme-linked immunosorbent assays.

Authors:  Hongyan Zhang; Shuo Wang; Guozhen Fang
Journal:  J Immunol Methods       Date:  2011-03-01       Impact factor: 2.303

9.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

Review 10.  Porous polymer monoliths: amazingly wide variety of techniques enabling their preparation.

Authors:  Frantisek Svec
Journal:  J Chromatogr A       Date:  2009-10-02       Impact factor: 4.759

View more
  1 in total

1.  MICROFLUIDIC DEVICES FOR LABEL-FREE AND NON-INSTRUMENTED QUANTITATION OF UNAMPLIFIED NUCLEIC ACIDS BY FLOW DISTANCE MEASUREMENT.

Authors:  Debolina Chatterjee; Danielle S Mansfield; Adam T Woolley
Journal:  Anal Methods       Date:  2014-10-21       Impact factor: 2.896

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.