Literature DB >> 22875409

Effects of the left ventricular assist device on the compliance and distensibility of the carotid artery.

Danielle L Templeton1, Ranjit John, Patricia Painter, Aaron S Kelly, Donald R Dengel.   

Abstract

We investigated the impact of continuous-flow left ventricular assist devices (LVAD) on the carotid elastic properties. Carotid artery parameters (diameter distensibility (DD), cross-sectional distensibility (CSD), diameter compliance (DC), cross-sectional compliance (CSC), and incremental elastic modulus (IEM)) were measured in a cross-sectional study using a standard ultrasound with a 10-MHz linear array probe. Measurements (mean ± SEM) were made in separate groups at various clinical time points: prior to LVAD surgery (baseline; 13 male/3 female; age 48 ± 3 years), 1 week following LVAD placement (acute; 12 male/2 female; age 47 ± 3 years), approximately 24 weeks following LVAD surgery (chronic; 13 male/2 female; age 52 ± 3 years), and in a group of healthy subjects (controls; 9 male/1 female; age 51 ± 4 years). Distensibility properties were lower (P < 0.05) in the acute (DD 2.3 % ± 0.4 %; CSD 4.7 % ± 0.8 %) and chronic (DD 2.2 % ± 0.4 %; CSD 4.5 ± 0.9 %) compared with the baseline (DD 5.9 % ± 0.7 %; CSD 12.2 % ± 1.5 %) and control (DD 5.8 % ± 0.6 %; CSD 11.9 % ± 1.3 %) groups. Compliance properties were lower (P < 0.05) in the chronic (DC 4.4 ± 0.7 mm/mmHg × 10(-3); CSC 1.2 ± 0.2 mmHg(-1) × 10(-3)) compared with acute (DC 9.0 ± 1.6 mm/mmHg × 10(-3); CSC 2.6 ± 0.4 mmHg(-1) × 10(-3)) and baseline (DC 11.1 ± 1.1 mm/mmHg × 10(-3); CSC 3.3 ± 0.4 mmHg(-1) × 10(-3)) groups. The compliance properties in the control (DC 8.3 ± 0.8 mm/mmHg × 10(-3); CSC 2.4 ± 0.2 mmHg(-1) × 10(-3)) group were not different from any of the patient groups. The IEM was higher (P < 0.05) in the chronic (6908 ± 1269 mmHg) compared with acute (2739 ± 412 mmHg), baseline (1849 ± 177 mmHg), and control (2349 ± 241 mmHg) groups. Chronic continuous-flow LVAD support is associated with lower carotid artery compliance and distensibility, which may place further strain on the left ventricle.

Entities:  

Mesh:

Year:  2012        PMID: 22875409     DOI: 10.1007/s00380-012-0271-4

Source DB:  PubMed          Journal:  Heart Vessels        ISSN: 0910-8327            Impact factor:   2.037


  33 in total

1.  Arterial stiffness and the development of hypertension. The ARIC study.

Authors:  D Liao; D K Arnett; H A Tyroler; W A Riley; L E Chambless; M Szklo; G Heiss
Journal:  Hypertension       Date:  1999-08       Impact factor: 10.190

2.  Myocardial histological changes in dilated cardiomyopathy during a long-term left ventricular assist device support.

Authors:  S Taketani; Y Sawa; N Fukushima; T Masai; N Kawaguchi; S Onishi; H Matsuda
Journal:  Heart Vessels       Date:  1997       Impact factor: 2.037

3.  Prediction of carotid plaques in hypertensive patients by risk factors, left ventricular hypertrophy, and epicardial adipose tissue thickness.

Authors:  Sante D Pierdomenico; Mariantonietta Mancini; Chiara Cuccurullo; Maria D Guglielmi; Anna M Pierdomenico; Marta Di Nicola; Silvio Di Carlo; Domenico Lapenna; Franco Cuccurullo
Journal:  Heart Vessels       Date:  2012-03-17       Impact factor: 2.037

Review 4.  Outcomes and complications after heart transplantation: a review.

Authors:  Frances M Hoffman
Journal:  J Cardiovasc Nurs       Date:  2005 Sep-Oct       Impact factor: 2.083

5.  Regular physical exercise improves endothelial function in heart transplant recipients.

Authors:  Alice Schmidt; Johannes Pleiner; Michaela Bayerle-Eder; Günther F Wiesinger; Suzanne Rödler; Michael Quittan; Gert Mayer; Michael Wolzt
Journal:  Clin Transplant       Date:  2002-04       Impact factor: 2.863

6.  Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis.

Authors:  D S Celermajer; K E Sorensen; V M Gooch; D J Spiegelhalter; O I Miller; I D Sullivan; J K Lloyd; J E Deanfield
Journal:  Lancet       Date:  1992-11-07       Impact factor: 79.321

Review 7.  Short- and long-term mechanical ventricular assistance towards myocardial recovery.

Authors:  John W C Entwistle
Journal:  Surg Clin North Am       Date:  2004-02       Impact factor: 2.741

8.  Simulation of systolic and diastolic left ventricular dysfunction in a mock circulation: the effect of arterial compliance.

Authors:  T G Papaioannou; D S Mathioulakis; S G Tsangaris
Journal:  J Med Eng Technol       Date:  2003 Mar-Apr

9.  Carotid arterial compliance in patients with congestive heart failure secondary to idiopathic dilated cardiomyopathy.

Authors:  S G Lage; L Kopel; M C Monachini; C J Medeiros; F Pileggi; J F Polak; M A Creager
Journal:  Am J Cardiol       Date:  1994-10-01       Impact factor: 2.778

10.  Arterial mechanics in ischemic versus nonischemic cardiomyopathy: clinical and diagnostic impact.

Authors:  Hala Mahfouz Badran; Abdallh Mostafa; Amany Serage; Walla Fareed; Ehab Abdelfatah; Adnan Fathe
Journal:  Echocardiography       Date:  2009-08       Impact factor: 1.724

View more
  3 in total

1.  Vascular inflammation and abnormal aortic histomorphometry in patients after pulsatile- and continuous-flow left ventricular assist device placement.

Authors:  Mike Lee; Hirokazu Akashi; Tomoko S Kato; Hiroo Takayama; Christina Wu; Katherine Xu; Elias Collado; Matthew P Weber; Peter J Kennel; Danielle L Brunjes; Ruiping Ji; Yoshifumi Naka; Isaac George; Donna Mancini; Maryjane Farr; P Christian Schulze
Journal:  J Heart Lung Transplant       Date:  2016-01-06       Impact factor: 10.247

2.  The study on hemodynamic effect of series type LVAD on aortic blood flow pattern: a primary numerical study.

Authors:  Qi Zhang; Bin Gao; Yu Chang
Journal:  Biomed Eng Online       Date:  2016-12-28       Impact factor: 2.819

3.  Effect of Different Rotational Directions of BJUT-II VAD on Aortic Swirling Flow Characteristics: A Primary Computational Fluid Dynamics Study.

Authors:  Qi Zhang; Bin Gao; Yu Chang
Journal:  Med Sci Monit       Date:  2016-07-21
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.