Literature DB >> 22874891

Measurement of central aortic pulse pressure: noninvasive brachial cuff-based estimation by a transfer function vs. a novel pulse wave analysis method.

Hao-Min Cheng1, Shih-Hsien Sung, Yuan-Ta Shih, Shao-Yuan Chuang, Wen-Chung Yu, Chen-Huan Chen.   

Abstract

BACKGROUND: The prognostic value of central aortic pulse pressure (PP-C) may have been underestimated due to its measurement inaccuracy. We aimed to investigate the accuracy of noninvasive brachial cuff-based estimation of PP-C by a generalized transfer function (GTF) or a novel pulse wave analysis (PWA) approach to directly estimate PP-C.
METHODS: Invasive high-fidelity right brachial and central aortic pressure tracings, and left brachial pulse volume plethysmography (PVP) waveforms from an oscillometric blood pressure (BP) monitor were all digitized simultaneously in 40 patients during cardiac catheterization. An aortic-to-brachial GTF and a PWA multivariate prediction model using the PVP waveforms calibrated to brachial cuff systolic BP (SBP) and diastolic BP(DBP) were constructed. Accuracy of the two methods was examined in another 100 patients against invasively measured PP-C.
RESULTS: The error of cuff PP in estimating PP-C was 1.8 ± 12.4 mm Hg. Application of the GTF on noninvasively calibrated PVP waveforms produced reconstructed aortic pressure waves and PP-C estimates with errors of -3.4 ± 11.6 mm Hg (PP-C = reconstructed aortic SBP - aortic DBP) and -2.3 ± 11.4 mm Hg (PP-C = reconstructed aortic SBP - cuff DBP), respectively. The observed systematic errors were proportional to the magnitudes of PP-C. In contrast, the error of the PWA prediction model was 3.0 ± 7.1 mm Hg without obvious proportional systematic error.
CONCLUSIONS: Large random and systematic errors are introduced into the PP-C estimates when PP-C is calculated as the difference between the estimated central SBP and central or cuff DBP. The accuracy can be improved substantially with the novel PWA approach.

Entities:  

Mesh:

Year:  2012        PMID: 22874891     DOI: 10.1038/ajh.2012.116

Source DB:  PubMed          Journal:  Am J Hypertens        ISSN: 0895-7061            Impact factor:   2.689


  12 in total

1.  Patient-Specific Oscillometric Blood Pressure Measurement.

Authors:  Jiankun Liu; Hao-Min Cheng; Chen-Huan Chen; Shih-Hsien Sung; Mohsen Moslehpour; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  IEEE Trans Biomed Eng       Date:  2015-10-15       Impact factor: 4.538

2.  Practical Suitability of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Review of the Microlife WatchBP Office Central.

Authors:  Willem J Verberk; Hao-Min Cheng; Li-Chih Huang; Chia-Ming Lin; Yao-Pin Teng; Chen-Huan Chen
Journal:  Pulse (Basel)       Date:  2016-02-12

3.  Observer-Based Deconvolution of Deterministic Input in Coprime Multichannel Systems With Its Application to Noninvasive Central Blood Pressure Monitoring.

Authors:  Zahra Ghasemi; Woongsun Jeon; Chang-Sei Kim; Anuj Gupta; Rajesh Rajamani; Jin-Oh Hahn
Journal:  J Dyn Syst Meas Control       Date:  2020-05-25       Impact factor: 1.372

4.  A systematic review of invasive, high-fidelity pressure studies documenting the amplification of blood pressure from the aorta to the brachial and radial arteries.

Authors:  Denis Chemla; Sandrine Millasseau
Journal:  J Clin Monit Comput       Date:  2020-10-09       Impact factor: 1.977

5.  Patient-Specific Oscillometric Blood Pressure Measurement: Validation for Accuracy and Repeatability.

Authors:  Jiankun Liu; Hao-Min Cheng; Chen-Huan Chen; Shih-Hsien Sung; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  IEEE J Transl Eng Health Med       Date:  2016-12-14       Impact factor: 3.316

6.  Central blood pressure for the management of hypertension: Is it a practical clinical tool in current practice?

Authors:  Hao-Min Cheng; Shao-Yuan Chuang; Tzung-Dau Wang; Kazuomi Kario; Peera Buranakitjaroen; Yook-Chin Chia; Romeo Divinagracia; Satoshi Hoshide; Huynh Van Minh; Jennifer Nailes; Sungha Park; Jinho Shin; Saulat Siddique; Jorge Sison; Arieska Ann Soenarta; Guru Prasad Sogunuru; Apichard Sukonthasarn; Jam Chin Tay; Boon Wee Teo; Yuda Turana; Narsingh Verma; Yuqing Zhang; Ji-Guang Wang; Chen-Huan Chen
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-12-16       Impact factor: 3.738

7.  Central Blood Pressure Monitoring via a Standard Automatic Arm Cuff.

Authors:  Keerthana Natarajan; Hao-Min Cheng; Jiankun Liu; Mingwu Gao; Shih-Hsien Sung; Chen-Huan Chen; Jin-Oh Hahn; Ramakrishna Mukkamala
Journal:  Sci Rep       Date:  2017-10-31       Impact factor: 4.379

8.  Systemic arteriosclerosis is associated with left ventricular remodeling but not atherosclerosis: a TASCFORCE study.

Authors:  Jonathan R Weir-McCall; Matthew Lambert; Stephen J Gandy; Jill J F Belch; Ian Cavin; Shelley A Henderson; Roberta Littleford; Jennifer A Macfarlane; Shona Z Matthew; R Stephen Nicholas; Allan D Struthers; Frank Sullivan; Richard D White; J Graeme Houston
Journal:  J Cardiovasc Magn Reson       Date:  2018-01-30       Impact factor: 5.364

Review 9.  Validation of non-invasive central blood pressure devices: ARTERY Society task force consensus statement on protocol standardization.

Authors:  James E Sharman; Alberto P Avolio; Johannes Baulmann; Athanase Benetos; Jacques Blacher; C Leigh Blizzard; Pierre Boutouyrie; Chen-Huan Chen; Phil Chowienczyk; John R Cockcroft; J Kennedy Cruickshank; Isabel Ferreira; Lorenzo Ghiadoni; Alun Hughes; Piotr Jankowski; Stephane Laurent; Barry J McDonnell; Carmel McEniery; Sandrine C Millasseau; Theodoros G Papaioannou; Gianfranco Parati; Jeong Bae Park; Athanase D Protogerou; Mary J Roman; Giuseppe Schillaci; Patrick Segers; George S Stergiou; Hirofumi Tomiyama; Raymond R Townsend; Luc M Van Bortel; Jiguang Wang; Siegfried Wassertheurer; Thomas Weber; Ian B Wilkinson; Charalambos Vlachopoulos
Journal:  Eur Heart J       Date:  2017-10-01       Impact factor: 29.983

10.  Estimation of Cardiovascular Risk Predictors from Non-Invasively Measured Diametric Pulse Volume Waveforms via Multiple Measurement Information Fusion.

Authors:  Zahra Ghasemi; Jong Chan Lee; Chang-Sei Kim; Hao-Min Cheng; Shih-Hsien Sung; Chen-Huan Chen; Ramakrishna Mukkamala; Jin-Oh Hahn
Journal:  Sci Rep       Date:  2018-07-11       Impact factor: 4.379

View more