Literature DB >> 22872319

Comparison of nitrate augmented Tc-99m tetrofosmin gated SPECT imaging with FDG PET imaging for the assessment of myocardial viability in patients with severe left ventricular dysfunction.

Senthil Raja1, Baljinder Singh, Manoj Kumar Rohit, Kuruva Manohar, Raghava Kashyap, Anish Bhattacharya, B R Mittal.   

Abstract

BACKGROUND: Of various nuclear medicine techniques, F-18/flourodeoxyglucose (FDG) positron emission tomography (PET) is considered as the best modality for the assessment of viable myocardium (VM). In this study, we compared the diagnostic accuracy of nitrate augmented Tc-99m tetrofosmin gated G-single-photon emission computed tomography (SPECT) with FDG PET.
METHODS: 54 consecutive cases of angiographically proven CAD with severe LV dysfunction were enrolled in the study. The patients underwent Tc-99m tetrofosmin G-SPECT and FDG PET as per the standard protocols and were compared.
RESULTS: SPECT data analysis indicated functional abnormalities in 661/918 myocardial segments. F-18 FDG PET revealed VM in 496/661 segments. The diagnostic accuracy of baseline NAC, postnitrate NAC, baseline AC, and postnitrate AC Tc-99m tetrofosmin SPECT was 84%, 87%, 90%, and 94%, respectively. κ values for NAC baseline, NAC postnitrate, AC baseline, and AC postnitrate Tc-99m tetrofosmin G-SPECT were 0.65, 0.70, 0.77, and 0.85, respectively. Attenuation correction revealed viability additionally in 46 segments which were non-viable on NAC postnitrate study (P < .001). Nitrate augmentation showed viability additionally in 25 segments which were non-viable on AC baseline scan (P = .004). On patient-based analysis FDG PET changes the management only in 13% (7/54) of patients.
CONCLUSIONS: Nitrate augmented AC Tc-99m tetrofosmin G-SPECT shows excellent (κ = .85) agreement with FDG PET. FDG PET changes management only in 13% of the patients. Tc-99m tetrofosmin G-SPECT being more widely available and cheaper imaging modality can be reliably used to detect VM where FDG PET is not available.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22872319     DOI: 10.1007/s12350-012-9607-9

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  24 in total

1.  Added value of attenuation-corrected Tc-99m tetrofosmin SPECT for the detection of myocardial viability: comparison with FDG SPECT.

Authors:  Riemer H J A Slart; Jeroen J Bax; Wim J Sluiter; Dirk J van Veldhuisen; Pieter L Jager
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

2.  Predictive value of dobutamine echocardiography and positron emission tomography in identifying hibernating myocardium in patients with postischaemic heart failure.

Authors:  D Pagano; R S Bonser; J N Townend; F Ordoubadi; R Lorenzoni; P G Camici
Journal:  Heart       Date:  1998-03       Impact factor: 5.994

3.  Nitrate administration increases blood flow in dysfunctional but viable myocardium, leading to improved assessment of myocardial viability: A PET study.

Authors:  Riemer H J A Slart; Ali Agool; Dirk J van Veldhuisen; Rudi A Dierckx; Jeroen J Bax
Journal:  J Nucl Med       Date:  2006-08       Impact factor: 10.057

4.  Low-dose dobutamine electrocardiograph-gated myocardial SPECT for identifying viable myocardium: comparison with dobutamine stress echocardiography and PET.

Authors:  K Yoshinaga; K Morita; S Yamada; K Komuro; C Katoh; Y Ito; Y Kuge; T Kohya; A Kitabatake; N Tamaki
Journal:  J Nucl Med       Date:  2001-06       Impact factor: 10.057

Review 5.  Assessment of myocardial viability.

Authors:  Mark I Travin; Steven R Bergmann
Journal:  Semin Nucl Med       Date:  2005-01       Impact factor: 4.446

6.  F-18-fluorodeoxyglucose positron emission tomography imaging-assisted management of patients with severe left ventricular dysfunction and suspected coronary disease: a randomized, controlled trial (PARR-2).

Authors:  Rob S B Beanlands; Graham Nichol; Ella Huszti; Dennis Humen; Normand Racine; Michael Freeman; Karen Y Gulenchyn; Linda Garrard; Robert deKemp; Ann Guo; Terrence D Ruddy; Francois Benard; André Lamy; Robert M Iwanochko
Journal:  J Am Coll Cardiol       Date:  2007-10-10       Impact factor: 24.094

7.  Tc-99m tetrofosmin tomography after nitrate administration in patients with ischemic left ventricular dysfunction: relation to metabolic imaging by PET.

Authors:  Wei He; Wanda Acampa; Ciro Mainolfi; Francesco Menna; Anna Rita Sorrentino; Mario Petretta; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2003 Nov-Dec       Impact factor: 5.952

8.  Attenuation-corrected 99mTc-tetrofosmin single-photon emission computed tomography in the detection of viable myocardium: comparison with positron emission tomography using 18F-fluorodeoxyglucose.

Authors:  I Matsunari; G Böning; S I Ziegler; S G Nekolla; J C Stollfuss; I Kosa; E P Ficaro; M Schwaiger
Journal:  J Am Coll Cardiol       Date:  1998-10       Impact factor: 24.094

9.  Enhanced detection of ischemic but viable myocardium by the reinjection of thallium after stress-redistribution imaging.

Authors:  V Dilsizian; T P Rocco; N M Freedman; M B Leon; R O Bonow
Journal:  N Engl J Med       Date:  1990-07-19       Impact factor: 91.245

10.  Rest and redistribution thallium-201 myocardial scintigraphy to predict improvement in left ventricular function after coronary arterial bypass grafting.

Authors:  A S Iskandrian; A H Hakki; S A Kane; I P Goel; E D Mundth; A H Hakki; B L Segal
Journal:  Am J Cardiol       Date:  1983-05-01       Impact factor: 2.778

View more
  3 in total

Review 1.  Application of animal and human PET in cardiac research.

Authors:  Quan Wang; Zhi-Gang He; Shun-Yuan Li; Mao-Hui Feng; Hong-Bing Xiang
Journal:  Am J Cardiovasc Dis       Date:  2018-06-15

2.  [Diagnostic work-up of coronary artery disease: Clinical value of different imaging methods].

Authors:  H Thiele; R Dörr; M Gutberlet
Journal:  Herz       Date:  2012-12       Impact factor: 1.443

3.  Diagnostic value of (18)F-FDG PET in the assessment of myocardial viability in coronary artery disease: A comparative study with (99m)Tc SPECT and echocardiography.

Authors:  Mansour Al Moudi; Zhong-Hua Sun
Journal:  J Geriatr Cardiol       Date:  2014-09       Impact factor: 3.327

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.