Literature DB >> 22868354

A column-switching liquid chromatography-tandem mass spectrometry method for quantitation of 2-cyanoethylmercapturic acid and 2-hydroxyethylmercapturic acid in Chinese smokers.

Hongwei Hou1, Wei Xiong, Na Gao, Xiaotao Zhang, Gangling Tang, Qingyuan Hu.   

Abstract

The acrylonitrile metabolites 2-cyanoethylmercapturic acid (CEMA) and 2-hydroxyethylmercapturic acid (HEMA) have been determined in human urine using an automated column-switching procedure. A diluted sample was centrifuged just prior to being injected into a reusable precolumn packed with a restricted access material and coupled to a liquid chromatography-tandem mass spectrometry system. This method achieved satisfactory reproducibility and accuracy. Average intra- and interday variations (% relative standard deviations) ranged from 2.4 to 3.8% for CEMA and from 2.7 to 10.5% for HEMA. The limits of quantification were 0.003 and 0.099ng/ml for CEMA and HEMA, respectively. It was used to study the uptake of acrylonitrile from smoke constituents by both nonsmokers and smokers of different tar yield cigarettes under ISO 3308 smoking condition. Metabolite concentrations in smoker urine samples were approximately 12 times higher compared with those in nonsmokers for CEMA and 3 times higher for HEMA. Urinary CEMA levels show a clear dose-response relationship with daily cigarette consumption and urinary cotinine. CEMA can also discriminate between smokers of different ISO cigarettes. Because HEMA is not specific, it is only slightly related to smoking and acrylonitrile exposure. The validated biomarker CEMA will continue to be useful for studies of acrylonitrile uptake by smokers.
Copyright © 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22868354     DOI: 10.1016/j.ab.2012.07.026

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  3 in total

Review 1.  Mercapturic acids: recent advances in their determination by liquid chromatography/mass spectrometry and their use in toxicant metabolism studies and in occupational and environmental exposure studies.

Authors:  Patricia I Mathias; Clayton B'hymer
Journal:  Biomarkers       Date:  2016-02-22       Impact factor: 2.658

Review 2.  A survey of liquid chromatographic-mass spectrometric analysis of mercapturic acid biomarkers in occupational and environmental exposure monitoring.

Authors:  Patricia I Mathias; Clayton B'Hymer
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2014-03-12       Impact factor: 3.205

3.  Longitudinal stability in cigarette smokers of urinary biomarkers of exposure to the toxicants acrylonitrile and acrolein.

Authors:  Menglan Chen; Steven G Carmella; Chistopher Sipe; Joni Jensen; Xianghua Luo; Chap T Le; Sharon E Murphy; Neal L Benowitz; F Joseph McClernon; Ryan Vandrey; Sharon S Allen; Rachel Denlinger-Apte; Paul M Cinciripini; Andrew A Strasser; Mustafa al'Absi; Jason D Robinson; Eric C Donny; Dorothy Hatsukami; Stephen S Hecht
Journal:  PLoS One       Date:  2019-01-04       Impact factor: 3.240

  3 in total