Literature DB >> 22867806

Fracture load of zirconia crowns according to the thickness and marginal design of coping.

Jee Hwan Kim1, Ji Hyun Park, Young Bum Park, Hong Seok Moon.   

Abstract

STATEMENT OF PROBLEM: The opaque color of zirconia copings may compromise esthetics, especially in the facial cervical area. A collarless zirconia coping can be an alternative. However, the strength of zirconia crowns with collarless copings is unknown.
PURPOSE: The purpose of this study was to compare the fracture load of zirconia crowns according to coping thickness and facial collar design.
MATERIAL AND METHODS: Forty-eight zirconia crowns were fabricated and divided into 4 groups: standard coping group (0.5 mm coping thickness, 0.2 mm facial collar height); collarless coping group (0.5 mm coping thickness, no facial collar); modified thicker coping group (0.7 mm coping thickness, 0.2 mm facial collar height); and thicker coping group (0.7 mm coping thickness including collar height). The fracture load for the crowns was measured in a universal testing machine. One-way ANOVA and the Tukey HSD test for post hoc analysis were used for statistical analysis (α=.05). Ten additional zirconia crowns were fabricated to test the effect of cyclic loading on fracture resistance between the standard coping group and the collarless coping group, and data were analyzed with the Mann-Whitney U test.
RESULTS: The fracture load in the collarless coping group (2329.1 N±948.3) was not significantly different from that of the other groups. The thicker coping group (3179.3 N±1137.7) resulted in significantly greater fracture load than the standard (2126.9 N±576.9) and modified thicker coping groups (2112.7 N±623.9) (F=4.193; P=.011). The fracture load after cyclic loading did not differ significantly between the standard coping group and the collarless coping group.
CONCLUSIONS: Within the limitations of this in vitro study, the thicker coping group had the highest fracture strength, but the collarless coping group using a 0.5 mm thickness coping was not significantly different from the standard coping group.
Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22867806     DOI: 10.1016/S0022-3913(12)60114-0

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Influence of Different Zirconia Coping Designs on the Fracture Resistance of All-Ceramic Crowns: An In Vitro Study.

Authors:  Sanath K Shetty; Tharammal Fayaz; Mohammed Zahid; Karkala S Suhaim; Mallikarjun Ragher; Mohammed S Hasan
Journal:  J Pharm Bioallied Sci       Date:  2020-08-28

2.  Fracture resistance of different primary anterior esthetic crowns.

Authors:  Manar Zaki Al Shobber; Thamer A Alkhadra
Journal:  Saudi Dent J       Date:  2017-08-09

3.  Effect of margin design on fracture load of zirconia crowns.

Authors:  Anneli Skjold; Christian Schriwer; Marit Øilo
Journal:  Eur J Oral Sci       Date:  2018-11-22       Impact factor: 2.612

4.  Effect of Incisal Porcelain Veneering Thickness on the Fracture Resistance of CAD/CAM Zirconia All-Ceramic Anterior Crowns.

Authors:  Noha Badran; Sanaa Abdel Kader; Fayza Alabbassy
Journal:  Int J Dent       Date:  2019-08-26

5.  Effect of different core design made of computer-aided design/computer-aided manufacturing system and veneering technique on the fracture resistance of zirconia crowns: A laboratory study.

Authors:  Ala'a Brijawi; Abdulaziz Samran; Ahlam Samran; Ali Alqerban; Muhammed Murad
Journal:  J Conserv Dent       Date:  2019 Jan-Feb

6.  Fracture Resistance of Sintered Monolithic Zirconia Dioxide in Different Thermal Units.

Authors:  Andrea Ordoñez Balladares; Cristian Abad-Coronel; Joao Carlos Ramos; Benjamín José Martín Biedma
Journal:  Materials (Basel)       Date:  2022-03-27       Impact factor: 3.623

7.  Fracture Resistance of Primary Zirconia Crowns: An In Vitro Study.

Authors:  AlWaleed Abushanan; Rajashekhara B Sharanesha; Bader Aljuaid; Tariq Alfaifi; Abdullah Aldurayhim
Journal:  Children (Basel)       Date:  2022-01-05
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.