Semi-quantitative thyr oid stimulating hormone (TSH) lateral flow immunochromatographic assays (LFA) are used to screen for serum TSH concentration >5 mIUL(-1) (hypothyroidism). The LFA format, however, is unable to measure TSH in the normal range or detect suppressed levels of TSH (<0.4 mIU L(-1); hyperthyroidism). In fact, it does not provide quantitative TSH values at all. Obtaining quantitative TSH results, especially in the low concentration range, has until now required the use of centralized clinical laboratories which require specimen transport, specialized equipment and personnel, and result in increased cost and delays in the timely reporting of important clinical results. We have conducted a series of experiments to develop and validate an optical system and image analysis algorithm based upon a cell phone platform. It is able to provide point-of-care quantitative TSH results with a high level of sensitivity and reproducibility comparable to that of a clinical laboratory-based third-generation TSH immunoassay. Our research approach uses the methodology of the optimized Rayleigh/Mie scatter detection by taking into consideration the optical characteristics of a nitrocellulose membrane and gold nanoparticles on an LFA for quantifying TSH levels. Using a miniature spectrometer, LED light source, and optical fibers on a rotating benchtop apparatus, the light intensity from different angles of incident light and angles of detection to the LFA were measured. The optimum angles were found that the minimized Mie scattering from nitrocellulose membrane, consequently maximizes the Rayleigh scatter detection from the gold nanoparticles in the LFA bands. Using the results from the benchtop apparatus, a cell-phone-based apparatus was designed which utilized the embedded flash in the cell phone camera as the light source, piped the light with an optical fiber from the flash through a collimating lens to illuminate the LFA. Quantification of TSH was performed in an iOS application directly on the phone and verified using the code written in MATLAB. The limit of detection of the system was determined to be 0.31 mIU L(-1) (never achieved before on an LFA format), below the commonly accepted minimum concentration of 0.4 mIU L(-1) indicating clinical significance of hyperthyroidism. The system was further evaluated using human serum showing an accurate and reproducible platform for rapid and point-of-care quantification of TSH using a cell phone.
Copyright © 2012 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22863118     DOI: 10.1016/j.bios.2012.07.014

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  45 in total

1.  Albumin testing in urine using a smart-phone.

Authors:  Ahmet F Coskun; Richie Nagi; Kayvon Sadeghi; Stephen Phillips; Aydogan Ozcan
Journal:  Lab Chip       Date:  2013-11-07       Impact factor: 6.799

2.  Quantification of plant chlorophyll content using Google Glass.

Authors:  Bingen Cortazar; Hatice Ceylan Koydemir; Derek Tseng; Steve Feng; Aydogan Ozcan
Journal:  Lab Chip       Date:  2015-02-11       Impact factor: 6.799

3.  A low-cost smartphone-based platform for highly sensitive point-of-care testing with persistent luminescent phosphors.

Authors:  Andrew S Paterson; Balakrishnan Raja; Vinay Mandadi; Blane Townsend; Miles Lee; Alex Buell; Binh Vu; Jakoah Brgoch; Richard C Willson
Journal:  Lab Chip       Date:  2017-03-14       Impact factor: 6.799

4.  Fluorescent imaging of single nanoparticles and viruses on a smart phone.

Authors:  Qingshan Wei; Hangfei Qi; Wei Luo; Derek Tseng; So Jung Ki; Zhe Wan; Zoltán Göröcs; Laurent A Bentolila; Ting-Ting Wu; Ren Sun; Aydogan Ozcan
Journal:  ACS Nano       Date:  2013-09-12       Impact factor: 15.881

5.  A chemiluminescent platform for smartphone monitoring of H2O2 in human exhaled breath condensates.

Authors:  Miguel E Quimbar; Katherine M Krenek; Alexander R Lippert
Journal:  Methods       Date:  2016-05-24       Impact factor: 3.608

Review 6.  Novel developments in mobile sensing based on the integration of microfluidic devices and smartphones.

Authors:  Ke Yang; Hagit Peretz-Soroka; Yong Liu; Francis Lin
Journal:  Lab Chip       Date:  2016-02-22       Impact factor: 6.799

Review 7.  A review on wax printed microfluidic paper-based devices for international health.

Authors:  S Altundemir; A K Uguz; K Ulgen
Journal:  Biomicrofluidics       Date:  2017-08-30       Impact factor: 2.800

8.  Orientational binding modes of reporters in a viral-nanoparticle lateral flow assay.

Authors:  Jinsu Kim; Ryan Poling-Skutvik; João R C Trabuco; Katerina Kourentzi; Richard C Willson; Jacinta C Conrad
Journal:  Analyst       Date:  2016-12-19       Impact factor: 4.616

Review 9.  Cellphone-based devices for bioanalytical sciences.

Authors:  Sandeep Kumar Vashist; Onur Mudanyali; E Marion Schneider; Roland Zengerle; Aydogan Ozcan
Journal:  Anal Bioanal Chem       Date:  2013-11-28       Impact factor: 4.142

Review 10.  Biomedical imaging and sensing using flatbed scanners.

Authors:  Zoltán Göröcs; Aydogan Ozcan
Journal:  Lab Chip       Date:  2014-09-07       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.