Biomechanical implant treatment complications: a systematic review of clinical studies of implants with at least 1 year of functional loading.

Yung-Ting Hsu1, Jia-Hui Fu, Khalid Al-Hezaimi, Hom-Lay Wang.   

Abstract

PURPOSE: The aim of this article is to discuss the current literature available on the etiology and management of biomechanical complications of dental implant treatment.
MATERIALS AND METHODS: An electronic search of the PubMed database for English-language articles published before May 31, 2011, was performed based on a focus question: "How can biomechanical implant treatment complications be managed and identified?" The key words used were "dental implant," "etiology," "management," "excessive occlusal forces," "occlusal forces," "occlusion," "parafunctional habits," "biomechanical failure," "biomechanical complications," and "occlusal overloading." Clinical trials with a minimum of 10 implants followed for at least 1 year after functional loading were included.
RESULTS: The initial electronic search identified 2,087 publications, most of which were eliminated, as they were animal studies, finite element analyses, bench-top studies, case reports, and literature reviews. After the titles, abstracts, and full text of 39 potentially eligible publications were reviewed, 15 studies were found to fulfill the inclusion criteria.
CONCLUSION: Occlusal overloading was thought to be the primary etiologic factor in biomechanical implant treatment complications, which commonly included marginal bone loss, fracture of resin/ceramic veneers and porcelain, retention device or denture base fracture of implant-supported overdentures, loosening or fracture of abutment screws, and even implant failure. Occlusal overloading was positively associated with parafunctional habits such as bruxism. An appreciation of the intricacy of implant occlusion would allow clinicians to take a more preventive approach when performing implant treatment planning, as avoidance of implant overloading helps to ensure the long-term stability of implant-supported prostheses.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22848892

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  14 in total

1.  Stress distribution of various designs of prostheses on short implants or standard implants in posterior maxilla: a three dimensional finite element analysis.

Authors:  K Jomjunyong; P Rungsiyakull; C Rungsiyakull; W Aunmeungtong; M Chantaramungkorn; P Khongkhunthian
Journal:  Oral Implantol (Rome)       Date:  2017-01-21

2.  Novel Techniques with the Aid of a Staged CBCT Guided Surgical Protocol.

Authors:  Evdokia Chasioti; Mohammed Sayed; Howard Drew
Journal:  Case Rep Dent       Date:  2015-01-06

3.  Surgical Treatment of Peri-Implantitis: A 17-Year Follow-Up Clinical Case Report.

Authors:  Fabrizio Bassi; Pier Paolo Poli; Davide Rancitelli; Fabrizio Signorino; Carlo Maiorana
Journal:  Case Rep Dent       Date:  2015-05-12

4.  Temperature rise during removal of fractured components out of the implant body: an in vitro study comparing two ultrasonic devices and five implant types.

Authors:  Eric W Meisberger; Sjoerd J G Bakker; Marco S Cune
Journal:  Int J Implant Dent       Date:  2015-03-20

5.  Tardive Dyskinesia, Oral Parafunction, and Implant-Supported Rehabilitation.

Authors:  S Lumetti; G Ghiacci; G M Macaluso; M Amore; C Galli; E Calciolari; E Manfredi
Journal:  Case Rep Dent       Date:  2016-12-06

6.  Association between dental implants in the posterior region and traumatic occlusion in the adjacent premolars: a long-term follow-up clinical and radiographic analysis.

Authors:  Jae-Hong Lee; Helen Hye-In Kweon; Seong-Ho Choi; Young-Taek Kim
Journal:  J Periodontal Implant Sci       Date:  2016-12-26       Impact factor: 2.614

7.  Fractures of implant fixtures: a retroscccpective clinical study.

Authors:  Han-Chang Yu; Young-Kyun Kim
Journal:  Maxillofac Plast Reconstr Surg       Date:  2020-04-25

8.  Long-term cumulative survival and mechanical complications of single-tooth Ankylos Implants: focus on the abutment neck fractures.

Authors:  Hye Won Shim; Byoung-Eun Yang
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

9.  Immediately Loaded Bicortical Implants Inserted in Fresh Extraction and Healed Sites in Patients with and Without a History of Periodontal Disease.

Authors:  Łukasz R Pałka; Aleksandar Lazarov
Journal:  Ann Maxillofac Surg       Date:  2019 Jul-Dec

10.  Clinical, histopathological and immunohistochemical behavior of peri-implant soft tissue.

Authors:  Monica Mihaela Iacov-Crăiţoiu; Mihai Crăiţoiu
Journal:  Rom J Morphol Embryol       Date:  2020       Impact factor: 1.033

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.