Literature DB >> 22848884

An in vitro model to evaluate the accuracy of guided surgery systems.

Márcio Macedo Soares1, Nassim David Harari, Eduardo Seixas Cardoso, Marcelo Corrêa Manso, Marcio Baltazar Conz, Guaracilei Maciel Vidigal.   

Abstract

PURPOSE: An in vitro model was developed and tested to evaluate the precision of guided implant systems. The accuracy of dental implants placed with a flapless technique was analyzed using a stereolithographic template in vitro. Differences between the virtual and actual positions of the implants were measured.
MATERIALS AND METHODS: Six polyurethane mandibles with artificial silicone gums were fabricated, and each was fitted with an individual computed tomography (CT) guide. Stereolithographic guides were created using computer-aided design/computer-assisted manufacturing technology and virtual planning software. All stereolithographic guides had four holes for stabilization pins and three holes for cylindric implants. After implant placement, the mandibles were subjected to another CT scan to compare the actual implant positions with the planned positions. The pre- and postimplantation CT images were superimposed using digital processing image software to evaluate the linear and angular deviations between the virtual planning data and the surgical results.
RESULTS: The mean angular discrepancy between the virtual and actual positions of the 18 placed implants was 2.16 ± 0.92 degrees. Among the placed implants, 66.7% were situated a mean of 0.38 ± 0.03 mm apical to the planned vertical position, and 33.3% were situated 0.39 ± 0.03 mm coronal to the planned position.
CONCLUSIONS: Within the limitations of the present study, this tool showed promising accuracy in virtual implant placement.

Entities:  

Mesh:

Year:  2012        PMID: 22848884

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  5 in total

1.  Abridged Technique for Precise Implant Angulation.

Authors:  Praveen Perumal; Gopi Naveen Chander; Anitha Kuttae Viswanathan; Ramesh Reddy; B Muthukumar
Journal:  J Clin Diagn Res       Date:  2015-12-01

Review 2.  Flapless dental implant surgery and use of cone beam computer tomography guided surgery.

Authors:  D P Laverty; J Buglass; A Patel
Journal:  Br Dent J       Date:  2018-04-06       Impact factor: 1.626

3.  Presurgical Cone Beam Computed Tomography Bone Quality Evaluation for Predictable Immediate Implant Placement and Restoration in Esthetic Zone.

Authors:  Corina Marilena Cristache
Journal:  Case Rep Dent       Date:  2017-02-22

Review 4.  Trends in computer-aided manufacturing in prosthodontics: a review of the available streams.

Authors:  Jaafar Abduo; Karl Lyons; Mohammed Bennamoun
Journal:  Int J Dent       Date:  2014-04-08

5.  Modified Technique for CAD/CAM Guided Implant Planning in the Presence of Existing Hopeless Teeth.

Authors:  Andrew C Johnson; Vinay Jain; Swati Ahuja
Journal:  J Dent (Shiraz)       Date:  2020-03
  5 in total