Literature DB >> 22847672

SENSE with improved tolerance to inaccuracies in coil sensitivity maps.

Johannes M Peeters1, Miha Fuderer.   

Abstract

In this work, an extension of the Cartesian sensitivity encoding (SENSE) parallel imaging framework is proposed. In the well-known SENSE solution, the overdetermined reconstruction inversion problem is optimized to get the highest signal-to-noise ratio in the image. In this extension, the probability of artifacts due to incorrect knowledge of the receiver coil sensitivities is also taken into account. This is realized by assuming an uncertainty in measured receiver coil sensitivities to enable weighting of residual artifact level and signal-to-noise ratio in the inversion problem. This inversion problem can still be solved by a least-squares optimization without the need of any complex iterative scheme. Results in abdominal imaging show that artifact levels can be substantially reduced, at the cost of a signal-to-noise ratio penalty. The size of the signal-to-noise ratio penalty depends on the assumed inaccuracy of the coil sensitivities, sensitivity encoding acceleration factor, and coil configuration.
Copyright © 2012 Wiley Periodicals, Inc.

Mesh:

Year:  2012        PMID: 22847672     DOI: 10.1002/mrm.24400

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  RARE/turbo spin echo imaging with Simultaneous Multislice Wave-CAIPI.

Authors:  Borjan A Gagoski; Berkin Bilgic; Cornelius Eichner; Himanshu Bhat; P Ellen Grant; Lawrence L Wald; Kawin Setsompop
Journal:  Magn Reson Med       Date:  2015-02-02       Impact factor: 4.668

Review 2.  Motion artifacts in MRI: A complex problem with many partial solutions.

Authors:  Maxim Zaitsev; Julian Maclaren; Michael Herbst
Journal:  J Magn Reson Imaging       Date:  2015-01-28       Impact factor: 4.813

Review 3.  State-of-the-art magnetic resonance imaging sequences for pediatric body imaging.

Authors:  Mareen Sarah Kraus; Ailish C Coblentz; Vibhas S Deshpande; Johannes M Peeters; Pedro M Itriago-Leon; Govind B Chavhan
Journal:  Pediatr Radiol       Date:  2022-10-18

4.  Chemical exchange saturation transfer (CEST) imaging with fast variably-accelerated sensitivity encoding (vSENSE).

Authors:  Yi Zhang; Hye-Young Heo; Dong-Hoon Lee; Shanshan Jiang; Xuna Zhao; Paul A Bottomley; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2016-07-01       Impact factor: 4.668

Review 5.  Rapid Imaging: Recent Advances in Abdominal MRI for Reducing Acquisition Time and Its Clinical Applications.

Authors:  Jeong Hee Yoon; Marcel Dominik Nickel; Johannes M Peeters; Jeong Min Lee
Journal:  Korean J Radiol       Date:  2019-12       Impact factor: 3.500

  5 in total