Literature DB >> 2284332

Dose-response curves for Fricke-infused agarose gels as obtained by nuclear magnetic resonance.

R J Schulz1, A F deGuzman, D B Nguyen, J C Gore.   

Abstract

The radiation-response characteristics of agarose gels prepared with Fricke dosemeter solution have been studied. The response mechanism is an increase in the NMR longitudinal relaxation rate of protons caused by ferric ions. It has been observed that: (i) oxygen saturation assures consistent and maximum sensitivity; (ii) agarose concentrations in the range 1.0-2.0% have no effect upon sensitivity; (iii) the initial G value is 150 Fe3+/100 eV for gels containing 0.5 mM Fe2+ ions; (iv) increasing NMR frequencies only causes a moderate increase in sensitivity; (v) the gel dosemeters are dose rate independent in the range 4.7-24.2 Gy min-1; (vi) sensitivity is pH dependent, being zero at pH 7; (vii) freshly prepared gels are slightly more sensitive than those more than 24 h old; and (ix) the diffusion coefficient for ferric ions in a 1.0% agarose gel containing 0.0125 M H2SO4 is 1.83 x 10(-2) cm2 h-1, and this will require consideration for the NMR imaging of dose distributions.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2284332     DOI: 10.1088/0031-9155/35/12/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Optical scanner for 3D radiotherapy polymer gel dosimetry.

Authors:  Piotr Sobotka; Marek Kozicki; Piotr Maras; Ł Boniecki; K Kacperski; A W Domański
Journal:  Acta Phys Pol A       Date:  2012-11       Impact factor: 0.577

2.  Radiological properties of nanocomposite Fricke gel dosimeters for heavy ion beams.

Authors:  Takuya Maeyama; Nobuhisa Fukunishi; Kenichi L Ishikawa; Kazuaki Fukasaku; Shigekazu Fukuda
Journal:  J Radiat Res       Date:  2016-03-10       Impact factor: 2.724

3.  Study of the Optimal Composition and Storage Conditions of the Fricke-XO-Pluronic F-127 Radiochromic Dosimeter.

Authors:  Michał Piotrowski; Piotr Maras; Sławomir Kadłubowski; Marek Kozicki
Journal:  Materials (Basel)       Date:  2022-01-27       Impact factor: 3.623

Review 4.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19

5.  The measurement of three dimensional dose distribution of a ruthenium-106 ophthalmological applicator using magnetic resonance imaging of BANG polymer gels.

Authors:  M F Chan; A Y Fung; Y C Hu; C S Chui; H Amols; M Zaider; D Abramson
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

6.  Improvement in sensitivity of radiochromic 3D dosimeter based on rigid polyurethane resin by incorporating tartrazine.

Authors:  Jin Dong Cho; Jaeman Son; Chang Heon Choi; Jin Sung Kim; Hong-Gyun Wu; Jong Min Park; Jung-In Kim
Journal:  PLoS One       Date:  2020-03-16       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.