Literature DB >> 22835836

Impact of galvanic corrosion on lead release from aged lead service lines.

Yin Wang1, He Jing, Vrajesh Mehta, Gregory J Welter, Daniel E Giammar.   

Abstract

Partial lead service line replacement (PLSLR) may be performed when tap water lead concentrations exceed the action level and in association with water main replacement or other maintenance. Partially replacing lead pipes with copper tubing can create a galvanic couple if the lead and copper are connected by a metal coupling, which can potentially enhance lead release by galvanic corrosion. The effect of two types of couplings, brass and plastic, on lead release after a simulated PLSLR was investigated in a set of laboratory-scale experiments. Experiments were conducted in a recirculation flow mode with intermittent stagnation periods using aged lead pipes harvested from Providence, RI. Release of both dissolved and particulate lead was higher for the brass-coupled systems than for the plastic-coupled systems, and galvanic corrosion was the primary cause of significant particulate lead release from the brass-coupled systems. For brass-coupled systems, longer stagnation times resulted in dramatically more release of particulate lead. Sampling of different volumes following stagnation showed that lead release for the brass-coupled systems was locally much higher in the region closest to the coupling. The impact of galvanic corrosion persisted for the six weeks of the experiment.
Copyright © 2012 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22835836     DOI: 10.1016/j.watres.2012.06.046

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  5 in total

1.  Sequential drinking water sampling as a tool for evaluating lead in flint, Michigan.

Authors:  Darren A Lytle; Michael R Schock; Kory Wait; Kelly Cahalan; Valerie Bosscher; Andrea Porter; Miguel Del Toral
Journal:  Water Res       Date:  2019-03-24       Impact factor: 11.236

2.  Mineralogical Evidence of Galvanic Corrosion in Drinking Water Lead Pipe Joints.

Authors:  Michael K DeSantis; Simoni Triantafyllidou; Michael R Schock; Darren A Lytle
Journal:  Environ Sci Technol       Date:  2018-02-28       Impact factor: 9.028

3.  Long-Term Behavior of Simulated Partial Lead Service Line Replacements.

Authors:  Justin St Clair; Clement Cartier; Simoni Triantafyllidou; Brandi Clark; Marc Edwards
Journal:  Environ Eng Sci       Date:  2016-01-01       Impact factor: 1.907

4.  Identifying the Gaps in Practice for Combating Lead in Drinking Water in Hong Kong.

Authors:  Wai Ling Lee; Jie Jia; Yani Bao
Journal:  Int J Environ Res Public Health       Date:  2016-09-30       Impact factor: 3.390

5.  The benefits and risks of consuming brewed tea: beware of toxic element contamination.

Authors:  Gerry Schwalfenberg; Stephen J Genuis; Ilia Rodushkin
Journal:  J Toxicol       Date:  2013-10-23
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.