Literature DB >> 22833507

Ultrasound-guided thoracotomy for implantation of an epicardial left ventricular lead after left pneumonectomy.

Guy Vandenplas1, Frederic Van Heuverswyn, Benny Drieghe, Stefaan Bouchez.   

Abstract

Surgical placement of a left ventricular epicardial pacing lead is a valuable alternative to the standard approach of endovascular placement of a pacing lead in the coronary sinus for cardiac resynchronization therapy. Despite higher perioperative morbidity, surgically placed leads perform well with lower revision and dislocation rates. Moreover, surgery is the only option when an endovascular approach proves to be unsuccessful. We report a successful implantation of an epicardial left ventricular lead through an ultrasound-guided lateral left mini-thoracotomy in a patient with a severely disturbed thoracic anatomy due to left pneumonectomy.

Entities:  

Mesh:

Year:  2012        PMID: 22833507      PMCID: PMC3480600          DOI: 10.1093/icvts/ivs325

Source DB:  PubMed          Journal:  Interact Cardiovasc Thorac Surg        ISSN: 1569-9285


  5 in total

1.  Guideline challenge: has CRT earned a Class I recommendation?

Authors:  Michele Coceani
Journal:  Circ Heart Fail       Date:  2010-05       Impact factor: 8.790

2.  Minimally invasive left ventricular epicardial lead placement: surgical techniques for heart failure resynchronization therapy.

Authors:  José L Navia; Fernando A Atik; Richard A Grimm; Mario Garcia; Pablo Ruda Vega; Ulf Myhre; Randall C Starling; Bruce L Wilkoff; David Martin; Penny L Houghtaling; Eugene H Blackstone; Delos M Cosgrove
Journal:  Ann Thorac Surg       Date:  2005-05       Impact factor: 4.330

3.  Event-free survival following CRT with surgically implanted LV leads versus standard transvenous approach.

Authors:  Amy L Miller; Daniel B Kramer; Eldrin F Lewis; Bruce Koplan; Laurence M Epstein; Usha Tedrow
Journal:  Pacing Clin Electrophysiol       Date:  2011-04       Impact factor: 1.976

4.  Surgically placed left ventricular leads provide similar outcomes to percutaneous leads in patients with failed coronary sinus lead placement.

Authors:  Gorav Ailawadi; Damien J Lapar; Brian R Swenson; Cory D Maxwell; Micah E Girotti; James D Bergin; John A Kern; John P Dimarco; Srijoy Mahapatra
Journal:  Heart Rhythm       Date:  2010-01-20       Impact factor: 6.343

5.  Real-time three-dimensional echocardiography permits quantification of left ventricular mechanical dyssynchrony and predicts acute response to cardiac resynchronization therapy.

Authors:  Nina Ajmone Marsan; Gabe B Bleeker; Claudia Ypenburg; Stefano Ghio; Nico R van de Veire; Eduard R Holman; Ernst E van der Wall; L Tavazzi; Martin J Schalij; Jeroen J Bax
Journal:  J Cardiovasc Electrophysiol       Date:  2007-12-20
  5 in total
  1 in total

1.  In vitro and in vivo studies on the biocompatibility of a self-powered pacemaker with a flexible buckling piezoelectric vibration energy harvester for rats.

Authors:  Feng Xie; Xiaoqing Qian; Ning Li; Daxiang Cui; Hao Zhang; Zhiyun Xu
Journal:  Ann Transl Med       Date:  2021-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.