Literature DB >> 22832144

Comparison of 3D and 2D FSE T2-weighted MRI in the diagnosis of deep pelvic endometriosis: preliminary results.

M Bazot1, A Stivalet, E Daraï, C Coudray, I Thomassin-Naggara, E Poncelet.   

Abstract

AIM: To evaluate image quality and diagnostic accuracy of two- (2D) and three-dimensional (3D) T2-weighted magnetic resonance imaging (MRI) for the evaluation of deep infiltrating endometriosis (DIE).
MATERIALS AND METHODS: One hundred and ten consecutive patients with suspicion of endometriosis were recruited at two institutions over a 5-month period. Twenty-three women underwent surgery, 18 had DIE at histology. Two readers independently evaluated 3D and 2D MRI for image quality and diagnosis of DIE. Descriptive analysis, chi-square test for categorical or nominal variables, McNemar test for comparison between 3D and 2D T2-weighted MRI, and weighted "statistics" for intra- and interobserver agreement were used for statistical analysis.
RESULTS: Both readers found that 3D yielded significantly lower image quality than 2D MRI (p < 0.0001). Acquisition time for 3D was significantly shorter than 2D MRI (p < 0.01). 3D offered similar accuracy to diagnose DIE compared to 2D MRI. For all locations of endometriosis, a high or variable intra-observer agreement was observed for reader 1 and 2, respectively.
CONCLUSIONS: Despite a lower overall image quality, 3D provides significant time saving and similar accuracy than multiplanar 2D MRI in the diagnosis of specific DIE locations.
Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22832144     DOI: 10.1016/j.crad.2012.05.014

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  7 in total

Review 1.  Imaging modalities for the non-invasive diagnosis of endometriosis.

Authors:  Vicki Nisenblat; Patrick M M Bossuyt; Cindy Farquhar; Neil Johnson; M Louise Hull
Journal:  Cochrane Database Syst Rev       Date:  2016-02-26

2.  Increased Speed and Image Quality for Pelvic Single-Shot Fast Spin-Echo Imaging with Variable Refocusing Flip Angles and Full-Fourier Acquisition.

Authors:  Andreas M Loening; Daniel V Litwiller; Manojkumar Saranathan; Shreyas S Vasanawala
Journal:  Radiology       Date:  2016-08-26       Impact factor: 11.105

3.  Standard high-resolution pelvic MRI vs. low-resolution pelvic MRI in the evaluation of deep infiltrating endometriosis.

Authors:  Arnaldo Scardapane; Filomenamila Lorusso; Marco Scioscia; Annunziata Ferrante; Amato Antonio Stabile Ianora; Giuseppe Angelelli
Journal:  Eur Radiol       Date:  2014-07-10       Impact factor: 5.315

4.  Meta-analysis and systematic review to determine the optimal imaging modality for the detection of uterosacral ligaments/torus uterinus, rectovaginal septum and vaginal deep endometriosis.

Authors:  B Gerges; W Li; M Leonardi; B W Mol; G Condous
Journal:  Hum Reprod Open       Date:  2021-11-04

5.  Magnetic resonance imaging and ultrasound fusion technique in gynecology.

Authors:  M Bazot; F Spagnoli; S Guerriero
Journal:  Ultrasound Obstet Gynecol       Date:  2022-01-12       Impact factor: 8.678

6.  European society of urogenital radiology (ESUR) guidelines: MR imaging of pelvic endometriosis.

Authors:  M Bazot; N Bharwani; C Huchon; K Kinkel; T M Cunha; A Guerra; L Manganaro; L Buñesch; A Kido; K Togashi; I Thomassin-Naggara; A G Rockall
Journal:  Eur Radiol       Date:  2016-12-05       Impact factor: 5.315

7.  Image quality improvement of single-shot turbo spin-echo magnetic resonance imaging of female pelvis using a convolutional neural network.

Authors:  Tomofumi Misaka; Nobuyuki Asato; Yukihiko Ono; Yukino Ota; Takuma Kobayashi; Kensuke Umehara; Junko Ota; Masanobu Uemura; Ryuichiro Ashikaga; Takayuki Ishida
Journal:  Medicine (Baltimore)       Date:  2020-11-20       Impact factor: 1.817

  7 in total