Literature DB >> 22831397

Cyclic fatigue resistance of two reciprocating nickel-titanium instruments after immersion in sodium hypochlorite.

E Pedullà1, N M Grande, G Plotino, F Palermo, G Gambarini, E Rapisarda.   

Abstract

AIM: To assess resistance to cyclic fatigue of reciprocating nickel-titanium ( NiTi ) files (Reciproc and WaveOne) after immersion in NaOCl solution over several time periods.
METHODOLOGY: A total of 90 new Reciproc R25 and WaveOne Primary were tested. The 45 files of the same brand were randomly assigned to three groups (n = 15) and submitted to the following immersion protocol in 5% NaOCl at 37 °C for 16 mm: no immersion (control), 1 or 5 min dynamically. The dynamic immersion and the following cyclic fatigue tests were performed using the appropriate preset reciprocation modes ('RECIPROC ALL' or 'WAVEONE ALL') in a specially designed endodontic motor. Resistance to cyclic fatigue was determined by recording time to fracture (TtF) in a stainless steel artificial canal with a 60° angle of curvature and 5 mm radius of curvature. The artificial canal was manufactured reproducing the instrument's size and taper. Data were analysed by 2-way analyses of variance.
RESULTS: Resistance to cyclic fatigue of the same NiTi file was not significantly affected by immersion in NaOCl . Reciproc R25 was associated with a higher cyclic fatigue resistance in all groups compared to WaveOne Primary (P < 0.0001).
CONCLUSIONS: Reciprocating dynamic immersion in NaOCl for 1 or 5 min did not reduce the cyclic fatigue resistance of NiTi files significantly. However, the type of reciprocating instrument influenced cyclic fatigue resistance with Reciproc R25 being more resistant than WaveOne Primary.
© 2012 International Endodontic Journal.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22831397     DOI: 10.1111/j.1365-2591.2012.02100.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  13 in total

1.  Cutting efficiency of nickel-titanium rotary and reciprocating instruments after prolonged use.

Authors:  Gianluca Gambarini; Alessio Giansiracusa Rubini; Giampaolo Sannino; Gianni Di Giorgio; Fabrizio Di Giorgio; Lucila Piasecki; Dina Al-Sudani; Gianluca Plotino; Luca Testarelli
Journal:  Odontology       Date:  2014-11-30       Impact factor: 2.634

2.  Deformations and cyclic fatigue resistance of nickel-titanium instruments inside a sequence.

Authors:  Gianluca Gambarini; Gianluca Plotino; Lucila Piasecki; Dina Al-Sudani; Luca Testarelli; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2015-05-18

3.  The influence of three different instrumentation techniques on the incidence of postoperative pain after endodontic treatment.

Authors:  Gianluca Gambarini; Luca Testarelli; Massimo De Luca; Valerio Milana; Gianluca Plotino; Nicola Maria Grande; Alessio Giansiracusa Rubini; Dina Al Sudani; Gianpaolo Sannino
Journal:  Ann Stomatol (Roma)       Date:  2013-03-20

4.  Cyclic fatigue resistance of D-RaCe, ProTaper, and Mtwo nickel-titanium retreatment instruments after immersion in sodium hypochlorite.

Authors:  Hüseyin Sinan Topçuoğlu; Kanşad Pala; Ahmet Aktı; Salih Düzgün; Gamze Topçuoğlu
Journal:  Clin Oral Investig       Date:  2015-09-30       Impact factor: 3.573

5.  Histological evaluation of the cleaning effectiveness of two reciprocating single-file systems in severely curved root canals: Reciproc versus WaveOne.

Authors:  Maira de Souza Carvalho; Emílio Carlos Sponchiado; Angela Delfina Bitencourt Garrido; Lucas da Fonseca Roberti Garcia; André Augusto Franco Marques
Journal:  Eur J Dent       Date:  2015 Jan-Mar

6.  Cutting efficiency of instruments with different movements: a comparative study.

Authors:  Luigi Tocci; Gianluca Plotino; Dina Al-Sudani; Alessio Giansiracusa Rubini; Gianpaolo Sannino; Lucila Piasecki; Ermanno Putortì; Luca Testarelli; Gianluca Gambarini
Journal:  J Oral Maxillofac Res       Date:  2015-03-30

7.  A new device to test cutting efficiency of mechanical endodontic instruments.

Authors:  Alessio Giansiracusa Rubini; Gianluca Plotino; Dina Al-Sudani; Nicola M Grande; Gianpaolo Sonnino; Ermanno Putorti; Elisabetta Cotti; Luca Testarelli; Gianluca Gambarini
Journal:  Med Sci Monit       Date:  2014-03-06

Review 8.  Single file reciprocating systems: A systematic review and meta-analysis of the literature: Comparison of reciproc and WaveOne.

Authors:  Rana Alsilani; Fatima Jadu; Dania F Bogari; Ahmed M Jan; Turki Y Alhazzazi
Journal:  J Int Soc Prev Community Dent       Date:  2016-10-24

9.  Comparison of cyclic fatigue resistance of original and counterfeit rotary instruments.

Authors:  Huseyin Ertas; Ismail Davut Capar; Hakan Arslan; Ender Akan
Journal:  Biomed Eng Online       Date:  2014-05-31       Impact factor: 2.819

10.  The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study.

Authors:  Taha Özyürek; Koray Yılmaz; Gülşah Uslu; Gianluca Plotino
Journal:  Restor Dent Endod       Date:  2018-02-02
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.