Literature DB >> 22828075

Torque expression of 0.018 and 0.022 inch conventional brackets.

Iosif Sifakakis1, Nikolaos Pandis, Margarita Makou, Theodore Eliades, Christos Katsaros, Christoph Bourauel.   

Abstract

The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.

Mesh:

Substances:

Year:  2012        PMID: 22828075     DOI: 10.1093/ejo/cjs041

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  7 in total

1.  Buccolingual Inclination Effects of Self-Ligating and Conventional Premolar Brackets: A Cone Beam Computed Tomography Study.

Authors:  Sabahat Yazıcıoğlu; A Alper Öz; A Zeynep Öz; Nursel Arıcı; Mete Özer; Selim Arıcı
Journal:  Turk J Orthod       Date:  2020-05-22

2.  The Tip and Torque adjustable bracket as a new concept in design.

Authors:  Ama Johal; Christoph Bourauel; Samir Moghanchi; Terry Dickerson; Paul Gaudin; Emma Louise Elliott
Journal:  Angle Orthod       Date:  2022-05-01       Impact factor: 2.684

3.  Torque expression capacity of 0.018 and 0.022 bracket slots by changing archwire material and cross section.

Authors:  Angela Arreghini; Luca Lombardo; Francesco Mollica; Giuseppe Siciliani
Journal:  Prog Orthod       Date:  2014-09-25       Impact factor: 2.750

4.  Torque efficiency of square and rectangular archwires into 0.018 and 0.022 in. conventional brackets.

Authors:  Spyridon N Papageorgiou; Iosif Sifakakis; Ioannis Doulis; Theodore Eliades; Christoph Bourauel
Journal:  Prog Orthod       Date:  2016-01-15       Impact factor: 2.750

5.  Computation and Collation of Torque Expression in 0.018 Inch and 0.022 Inch Preadjusted Bracket Slots on Passive Insertion of Full-Size Archwire: A Finite Element Study.

Authors:  A Anand Kumar; Sharmila Sekar; S Sathesh Kumar; G Divakar; Kumaran Vijayarangam; S Arulselvi
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

6.  A Comparison of the Ligation Torque Expression of a Ribbonwise Bracket-Archwire Combination and a Conventional Combination: A Primary Study.

Authors:  Bin Lin; Feifei Jiang; Jie Chen; Jiaxing Liang
Journal:  Int J Clin Pract       Date:  2022-09-28       Impact factor: 3.149

7.  Implications of pretreatment incisor inclinations for the achievement of cephalometric normal values-a study on two patient collectives.

Authors:  B Zimmer; H Sino; S Schenk-Kazan
Journal:  J Orofac Orthop       Date:  2021-07-07       Impact factor: 1.938

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.