Literature DB >> 22816786

Multiplexed fluorescence resonance energy transfer aptasensor between upconversion nanoparticles and graphene oxide for the simultaneous determination of mycotoxins.

Shijia Wu1, Nuo Duan, Xiaoyuan Ma, Yu Xia, Hongxin Wang, Zhouping Wang, Qian Zhang.   

Abstract

We presented a new aptasensor for mycotoxins, which was based on multiplexed fluorescence resonance energy transfer (FRET) between multicolor upconversion fluorescent nanoparticles (UCNPs) as donors and graphene oxide (GO) as the entire and effective acceptor. BaY(0.78)F(5):Yb(0.2), Er(0.02) and BaY(0.78)F(5):Yb(0.7), Tm(0.02) upconversion nanoparticles were synthesized and functionalized, respectively, with immobilized ochratoxin A (OTA)-aptamers and fumonisin B(1) (FB(1))-aptamers. On the basis of the strong π-π stacking effect between the nucleobases of the aptamers and the sp(2) atoms of GO, the aptamer modified-UCNPs can be brought in close proximity to the GO surface. The strong upconversion fluorescence both of BaY(0.78)F(5):Yb(0.2), Er(0.02) and BaY(0.78)F(5):Yb(0.2), Tm(0.02) can be completely quenched by the GO, because of a good overlap between the fluorescence emission of multicolor UCNPs and the absorption spectrum of GO. In contrast, in the presence of OTA and FB(1), the aptamers preferred to bind to their corresponding mycotoxins, which led to changes in the formation of aptamers, and therefore, aptamer modified-UCNPs were far away from the GO surface. Our study results showed that the fluorescence intensity of BaYF(5):Yb Er and BaYF(5):Yb Tm were related to the concentration of OTA and FB(1). We therefore developed a sensitive and simple platform for the simultaneous detection of OTA and FB(1) with multicolor UCNPs and GO as the FRET pair. The aptasensor provided a linear range from 0.05 to 100 ng·mL(-1) for OTA and 0.1 to 500 ng·mL(-1) for FB(1); the detection limit of OTA was 0.02 ng·mL(-1) and FB(1) was 0.1 ng·mL(-1). As a practical application, the aptasensor was used to monitor OTA and FB(1) level in naturally contaminated maize samples with the results consistent with that of a classic ELISA method. More importantly, the novel multiplexed FRET was established for the first time based on multiplexed energy donors to the entire energy acceptor; this work was expected to open up a new field of FRET system applications for various targets.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22816786     DOI: 10.1021/ac301534w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  35 in total

Review 1.  Design, synthesis, and characterization of graphene-nanoparticle hybrid materials for bioapplications.

Authors:  Perry T Yin; Shreyas Shah; Manish Chhowalla; Ki-Bum Lee
Journal:  Chem Rev       Date:  2015-02-18       Impact factor: 60.622

Review 2.  Luminescent Nanomaterials (II).

Authors:  Hyejin Chang; Jaehi Kim; Sang Hun Lee; Won-Yeop Rho; Jong Hun Lee; Dae Hong Jeong; Bong-Hyun Jun
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

3.  A fluorometric aptamer-based assay for ochratoxin A using magnetic separation and a cationic conjugated fluorescent polymer.

Authors:  Yufei Liu; Huijuan Yan; Jingfang Shangguan; Xue Yang; Meili Wang; Wei Liu
Journal:  Mikrochim Acta       Date:  2018-08-22       Impact factor: 5.833

4.  Photoinduced discharge of electrons stored in a TiO2-MWCNT composite to an analyte: application to the fluorometric determination of hydrogen peroxide, glucose and aflatoxin B1.

Authors:  Amina Rhouati; Muhammad Nasir; Jean-Louis Marty; Akhtar Hayat
Journal:  Mikrochim Acta       Date:  2017-12-06       Impact factor: 5.833

Review 5.  A review on recent developments in optical and electrochemical aptamer-based assays for mycotoxins using advanced nanomaterials.

Authors:  K Yugender Goud; K Koteshwara Reddy; M Satyanarayana; Shekher Kummari; K Vengatajalabathy Gobi
Journal:  Mikrochim Acta       Date:  2019-12-07       Impact factor: 5.833

6.  A Novel Fluorescent Biosensor for Detection of Silver Ions Based on Upconversion Nanoparticles.

Authors:  Qian Long; Yanqing Wen; Haitao Li; Youyu Zhang; Shouzhuo Yao
Journal:  J Fluoresc       Date:  2016-10-22       Impact factor: 2.217

7.  Simultaneous electrochemical determination of ochratoxin A and fumonisin B1 with an aptasensor based on the use of a Y-shaped DNA structure on gold nanorods.

Authors:  Min Wei; Lingkun Xin; Shuo Feng; Yong Liu
Journal:  Mikrochim Acta       Date:  2020-01-07       Impact factor: 5.833

8.  Magnetic beads-assisted fluorescence aptasensing approach based on dual DNA tweezers for detection of ochratoxin A and fumonisin B1 in wine and corn.

Authors:  Chenling Qu; Luyang Zhao; Xing He; Songcheng Yu; Min Wei
Journal:  Anal Bioanal Chem       Date:  2021-09-06       Impact factor: 4.142

Review 9.  Functional DNA nanomaterials for sensing and imaging in living cells.

Authors:  Seyed-Fakhreddin Torabi; Yi Lu
Journal:  Curr Opin Biotechnol       Date:  2014-01-25       Impact factor: 9.740

10.  An ultrasensitive, homogeneous fluorescence quenching immunoassay integrating separation and detection of aflatoxin M1 based on magnetic graphene composites.

Authors:  Xiya Zhang; Xijie Zhang; Lianjun Song; Xianqing Huang; Yu Li; Mingwu Qiao; Wanjing Liu; Tongtong Zhang; Yuchen Qi; Wuzhou Wang; Xuezhi Yu; Leina Dou; Huijuan Yang; Liye Wang; Yexuan Mao; Zhanhui Wang
Journal:  Mikrochim Acta       Date:  2021-01-28       Impact factor: 5.833

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.